You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

BOSCH REXROTH
0811104127


$1,893.07 USD
  • BOSCH REXROTH
  • Material:0811104127
  • Model:DZT-XA2-1X/315L

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Bosch Rexroth directly.***
The Bosch Rexroth DZT-XA2-1X/315 (0811104127) is a precision-engineered pressure relief valve designed for effective management of system pressures in hydraulic applications. This direct-operated valve, part of the DBT series, features a seat design and serves as a pilot control valve suitable for subplate mounting and control panel integration. The valve's construction includes a robust housing, a responsive valve poppet, and an accurately machined valve seat that together ensure reliable operation. The DZT-XA2-1X/315 operates by maintaining the connection between the P (pressure) and T (tank) ports closed under normal conditions via the force exerted by the valve poppet onto the valve seat. The manual setting adjustment allows operators to precisely set the system pressure threshold according to specific requirements. When system pressure reaches this predetermined level, as set by adjustment type (4), the hydraulic force overcomes spring resistance, causing the poppet to lift away from its seat. This action permits excess fluid to flow from P to T, thereby relieving pressure and safeguarding against potential overpressure damage. With its capability for fine-tuning, this Bosch pressure relief valve ensures that minimum system pressure does not fall below 3 bar due to spring preload force when completely unloaded. Its primary function as a pilot control valve enables it to indirectly manage larger flow rates by controlling smaller pilot flows. Overall, the Bosch DZT-XA2-1X/315 is an essential component for hydraulic systems requiring precise pressure regulation and safety. Its design emphasizes durability, accuracy in pressure settings, and adaptability for various industrial hydraulic applications where indirect control of large flows is necessary.

Pressure relief valves of type DBT are remote control valves with seat design and are used for limiting a system pressure.

The setting is completed manually, via the adjustment type (4).

The valves basically consist of the housing (1), the valve poppet (2) and the related valve seat (3).

In the unloaded position, the valve poppet (2) pushes onto the valve seat (3) and blocks the connection between P and T connection.

If the hydraulic force equals the force set at the adjustment type (4), the valve controls the set pressure.

By lifting off the valve poppet (2) from the valve seat (3), the excessive hydraulic fluid may flow off from P to T.

With completely unloaded spring (5), the minimum pressure of 3 bar (spring preload force) will settle.

These valves are basically used as pilot control valves for the indirect control of larger flows.

Type DBT-XP2-1X

technical illustration-0811104127-Direct operated valves for limiting a system pressure Use as pilot control valve For subplate mounting and control panel design

Ordering code, symbols

Type

Part number

Examples of application

Symbols

DBT–G1–1X/160

0 811 104 007

For control panel

technical illustration-0811104127-Direct operated valves for limiting a system pressure Use as pilot control valve For subplate mounting and control panel design
technical illustration-0811104127-Direct operated valves for limiting a system pressure Use as pilot control valve For subplate mounting and control panel design

 

DBT–G1–1X/315

 

0 811 104 013

DBT–G7–1X/160

0 811 104 021

 

DBT–XP8–1X/160

0 811 104 100

Sandwich plate for subplate mounting

technical illustration-0811104127-Direct operated valves for limiting a system pressure Use as pilot control valve For subplate mounting and control panel design

DBT–XP8–1X/315

0 811 104 101

DBT–XP2–1X/160

0 811 104 102

DBT–XP2–1X/315

0 811 104 103

DBT–XP7–1X/160

0 811 104 104

DBT–XP7–1X/315

0 811 104 105

DBT–XP3–1X/160

0 811 104 106

DBT–XP3–1X/315

0 811 104 107

DBT–XP1–1X/160

0 811 104 108

DBT–XP1–1X/315

0 811 104 109

ZDBT–XP8–1X/160

0 811 104 110

Sandwich plate for subplate mounting

technical illustration-0811104127-Direct operated valves for limiting a system pressure Use as pilot control valve For subplate mounting and control panel design

 

ZDBT–XP8–1X/315

0 811 104 111

 

ZDBT–XP2–1X/160

0 811 104 112

ZDBT–XP2–1X/315

0 811 104 113

ZDBT–XP7–1X/160

0 811 104 114

ZDBT–XP7–1X/315

0 811 104 115

ZDBT–XP3–1X/160

0 811 104 116

ZDBT–XP3–1X/315

0 811 104 117

 

ZDBT–XA8–1X/160

0 811 104 118

For subplate mounting

technical illustration-0811104127-Direct operated valves for limiting a system pressure Use as pilot control valve For subplate mounting and control panel design
technical illustration-0811104127-Direct operated valves for limiting a system pressure Use as pilot control valve For subplate mounting and control panel design

ZDBT–XA8–1X/315

0 811 104 119

ZDBT–XA2–1X/160

0 811 104 120

ZDBT–XA2–1X/315

0 811 104 121

DZT–XB2–1X/315

0 811 104 123

Pressure switch valve for subplate mounting

technical illustration-0811104127-Direct operated valves for limiting a system pressure Use as pilot control valve For subplate mounting and control panel design
technical illustration-0811104127-Direct operated valves for limiting a system pressure Use as pilot control valve For subplate mounting and control panel design

 

DZT–XB2–1X/60

0 811 104 124

 

DZT–XA2–1X/60

0 811 104 125

technical illustration-0811104127-Direct operated valves for limiting a system pressure Use as pilot control valve For subplate mounting and control panel design

DZT–XA2–1X/160

0 811 104 126

DZT–XA2–1X/315

0 811 104 127

general

Size

6

Weight

kg

2

Installation position

any

Ambient temperature range

°C

-20 … +70

Storage temperature range

°C

-20 … +80

hydraulic (measured with HLP 46; ϑ Oil = 40 °C ±5 °C, ν = 35 mm2/s)

Size

6

Maximum operating pressure

Port P

bar

350

Maximum set pressure

Pressure rating 60 bar 1)

bar

60

Pressure rating 16 bar

bar

160

Pressure rating 315 bar

bar

315

Pressure rating 350 bar

bar

350

Minimum set pressure

bar

3

Return flow

Port T

separate and depressurized to the tank

Maximum flow

l/min

3

Hydraulic fluid

Mineral oil (HL, HLP) according to DIN 51524, other hydraulic fluids on request

Hydraulic fluid temperature range

°C

-20 … +80

Viscosity range

mm²/s

15 … 380

Maximum admissible degree of contamination of the hydraulic fluid 2)

Class 20/18/15 according to ISO 4406 (c)

Hysteresis (deviation from the max. set pressure)

%

< 5

Pilot oil volume (Vx) (only pressure switch valves)

cm³

0.5
1) only possible with type DZT
2) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.

For applications outside these parameters, please consult us!

Δp = f (qV)

technical illustration-0811104127-Direct operated valves for limiting a system pressure Use as pilot control valve For subplate mounting and control panel design

(measured with HLP46, ϑOil = 40 ±5 °C), ν = 35 mm2/s)

Type DBT-G1-1X/...

Dimensions in mm

technical illustration-0811104127-Direct operated valves for limiting a system pressure Use as pilot control valve For subplate mounting and control panel design

1

Hand wheel

2

Rotary knob

3

Valve mounting bores

4

Pressure gauge connection

5

Lock nut

Valve mounting screws (separate order)

4 hexagon socket head cap screws M6,

screw length as required

Type DBT-X... Type ZDBT-X...

Dimensions in mm

technical illustration-0811104127-Direct operated valves for limiting a system pressure Use as pilot control valve For subplate mounting and control panel design

1

Name plate or 2nd flange surface

2

Adjustment type

3

Lock nut

4

Valve mounting bores

5

O-rings Ø9.25 x 1.78 mm (ports P, T)

6

Machined valve contact surface; Porting pattern according to ISO 4401-03-02-0-05

Subplates see data sheet 45052

Valve mounting screws (separate order)

type DBT

4 hexagon socket head cap screws ISO 4762-M5x50-10.9-flZn-240h-L

(friction coefficient μtotal = 0.09 – 0.14);

tightening torque MA = 7 Nm ±10 %

or

4 hexagon socket head cap screws ISO  4762-M5x50-10.9

(friction coefficient μtotal = 0.12 – 0.17);

tightening torque MA = 8.9 Nm ± 10%

type ZDBT

4 hexagon socket head cap screws ISO 4762-M5-10.9-flZn-240h-L

(friction coefficient μtotal = 0.09 – 0.14);

tightening torque MA = 7 Nm ±10 %

or

4 hexagon socket head cap screws ISO 4762-M5-10.9

(friction coefficient μtotal = 0.12 – 0.17);

tightening torque MA = 8.9 Nm ± 10%

Screw length as required

Type DZT-X...

Dimensions in mm

technical illustration-0811104127-Direct operated valves for limiting a system pressure Use as pilot control valve For subplate mounting and control panel design

1

Name plate

2

Adjustment element

3

Lock nut

4

Valve mounting bores

5

Pressure gauge connection for pilot pressure X, G1/4

6

Pressure gauge connection for system pressure A, G1/4

7

O-rings Ø10 x 1.5 mm (ports P, A, B, T)

8

Machined valve contact surface; Porting pattern according to ISO 4401-03-02-0-05

Subplates see data sheet 45052

Valve mounting screws (separate order)

4 hexagon socket head cap screws ISO 4762-M5x50-10.9-flZn-240h-L

(friction coefficient μtotal = 0.09 –0,14);

tightening torque MA =  7 Nm ± 10%

or

4 hexagon socket head cap screws ISO 4762-M5x50-10.9

(friction coefficient μtotal = 0.12 – 0.17);

tightening torque MA = 8.9 Nm ± 10%

Screw length as required

Examples of application

technical illustration-0811104127-Direct operated valves for limiting a system pressure Use as pilot control valve For subplate mounting and control panel design