BOSCH REXROTH
0811404042
$4,696.77 USD
- BOSCH REXROTH
- Material:0811404042
- Model:4WRPH6C3B04P-2X/G24Z4/M
Quantity in stock: 0
The Bosch Rexroth 4WRPH6C3B04P-2X/G24Z4/M (0811404042) is a state-of-the-art high-response valve designed for precision electro-hydraulic control applications. This direct operated valve features servo quality with a control spool and sleeve, ensuring accurate performance and reliability. It is uniquely designed to be actuated on one side, and when deactivated, it assumes a 4/4 fail-safe position, providing an added layer of operational safety. The valve's control solenoid is equipped with electrical position feedback and integrated electronics for the position transducer (Lvdt DC/DC), which allows for precise monitoring and control of the valve's position. This capability is essential in applications where exact hydraulic flow and pressure control are critical. Constructed for subplate mounting, the Bosch 4WRPH6C3B04P-2X/G24Z4/M adheres to the porting pattern standards set by ISO 4401, ensuring compatibility with a wide range of hydraulic systems. Its robust design makes it suitable for use in production lines and testing systems where high responsiveness and accuracy are required. The valve's reliability and precision make it an ideal choice for implementing electro-hydraulic controls in sophisticated machinery and equipment within various production environments.
Valves of type 4WRPH6 are direct operated high-response valve in servo quality with electric position feedback. The valves are actuated on one side and in their deactivated condition take a 4/4 fail-safe position. They are suitable for electro-hydraulic controls in production and test systems.
|
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
10 |
11 |
12 |
13 |
|||
|
4 |
WRP |
H |
6 |
B |
‒ |
2X |
/ |
G24 |
Z4 |
/ |
M |
* |
|
01 |
4 main ports |
4 |
|
02 |
High-response directional valve, direct operated |
WRP |
|
03 |
Control spool/sleeve |
H |
|
04 |
Size 6 |
6 |
|
05 |
Symbols; for the possible version, see "Symbols/Circuit diagrams" |
C1, C3, C4, C5 |
|
Installation side of the inductive position transducer |
||
|
06 |
Valve side B (standard) (see "Symbols/Circuit diagrams") |
B |
|
Rated flow at 70 bar valve pressure differential (35 bar/control edge) |
||
|
07 |
2 l/min |
02 |
|
4 l/min |
04 |
|
|
12 l/min |
12 |
|
|
15 l/min |
15 1) |
|
|
24 l/min |
24 |
|
|
25 l/min |
25 1) |
|
|
40 l/min |
40 3) |
|
|
Flow characteristic |
||
|
08 |
Linear |
L |
|
Inflected characteristic curve |
P 2) |
|
|
09 |
Component series 20 ... 29 (20 ... 29: unchanged installation and connection dimensions) - Size 6 |
2X |
|
Supply voltage of the control electronics |
||
|
10 |
Direct voltage 24 V |
G24 |
|
Electrical connection |
||
|
11 |
With connector according to DIN 43560-AM2, mating connector included in the scope of delivery |
Z4 |
|
Seal material |
||
|
12 |
NBR seals |
M |
|
13 |
Further details in the plain text |
* |
|
1) |
Only available with flow characteristics P |
|
|
2) |
Inflection 60 % for NG6 with rated flows "15" and "25", otherwise inflection 40 % |
|
|
3) |
qv 2:1 only with rated flow = 40 l/min |
|
For applications outside these parameters, please consult us!
general
|
Type |
4WRPH | |
|
Size |
6 | |
|
Component series |
2X | |
|
Type of actuation |
Proportional solenoid with position control, electrical amplifier external | |
|
Type of connection |
For subplate mounting: Porting pattern according to ISO 4401 | |
|
Installation position |
Any | |
|
Weight |
kg |
2.3 |
|
Ambient temperature range |
°C |
-20 … +50 |
hydraulic
|
Type |
4WRPH | ||
|
Size |
6 | ||
|
Maximum operating pressure |
bar |
315 | |
|
Maximum operating pressure |
Port P |
bar |
315 |
|
Port A |
bar |
315 | |
|
Port B |
bar |
315 | |
|
Port T |
bar |
250 | |
|
Maximum flow |
l/min |
40 | |
|
Nominal flow |
l/min |
2 4 12 15 24 40 |
|
|
Hydraulic fluid temperature range |
°C |
-20 … +80 | |
|
Viscosity range |
Maximum admissible |
mm²/s |
10 … 800 |
|
Recommended |
mm²/s |
20 … 100 | |
|
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 1) |
Class 18/16/13 according to ISO 4406 (c) | ||
|
Hysteresis |
% |
≤ 0.2 | |
|
Manufacturing tolerance |
% |
< 10 | |
| 1) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
hydraulic
|
Nominal flow 1) |
l/min |
2 | 4 | 12 | 15 | 24 | 40 | |
|
Limitation of use |
Symbols C, C3, C5 |
bar |
315 | 160 | ||||
|
Symbols C1, C4 |
bar |
315 | 280 | 250 | 100 | |||
|
Leakage flow (at 100 bar) |
Linear characteristic curve “L” |
l/min |
< 150 | < 180 | < 300 | - | < 500 | < 900 |
|
Inflected characteristic curve "P" |
l/min |
- | < 180 | < 300 | < 450 | |||
| 1) | With Δp = 35 bar/control edge |
electrical
|
Type |
4WRPH | ||
|
Size |
6 | ||
|
Power supply |
Nominal voltage |
V |
24 |
|
Maximum solenoid current |
A |
2.7 | |
|
Coil resistance with solenoid temperature 20 °C |
Ω |
2.5 | |
|
Duty cycle |
% |
100 | |
|
Maximum power consumption |
VA |
40 | |