You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

BOSCH REXROTH
0811404089


$7,221.23 USD
  • BOSCH REXROTH
  • Material:0811404089
  • Model:4WRPH10C1B100P-2X/G24K0/M-750

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Bosch Rexroth directly.***
The Bosch Rexroth 4WRPH10C1B100P-2X/G24K0/M-750 (0811404089) is a direct operated high-response valve characterized by its servo quality performance and robust design tailored for demanding environments. This valve features electric position feedback and is designed to be actuated on one side, ensuring a 4/4 fail-safe position when deactivated. The "Ruggedized" design denotes an enhanced durability capable of withstanding up to 40 g forces, making it exceptionally reliable for applications that encounter intense vibrations or shocks. The valve's construction allows for subplate mounting, with a porting pattern that conforms to ISO 4401 standards, facilitating ease of integration into various hydraulic systems. Its specialized capabilities make it particularly well-suited for use within the wood industry or in any installation facing aggravated environmental conditions where precision and resilience are paramount. The Bosch Rexroth 4WRPH10C1B100P-2X/G24K0/M-750 valve represents a blend of high responsiveness and ruggedness, ensuring optimal performance in challenging industrial settings.

Valves of type 4WRPH-750 are direct operated high-response valve in servo quality with electric position feedback and robust design. The valves are actuated on one side and in their deactivated condition take a 4/4 fail-safe position. They are suitable for use in the wood industry and in installations with aggravated environmental conditions

 

01

02

03

04

05

06

07

08

09

10

11

12

13

4

WRP

H

B

2X

/

G24

K0

/

M

750

01

4 main ports

4

02

High-response directional valve, direct operated

WRP

03

Control spool/sleeve

H

04

Size 6

6

Size 10

10

05

Symbols; for the possible version, see "Symbols/Circuit diagrams"

C1, C3, C4, C5

Installation side of the inductive position transducer

06

Valve side B (standard) (see "Symbols/Circuit diagrams")

B

Rated flow at 70 bar valve pressure differential (35 bar/control edge)

07

12 l/min

12

15 l/min

15 1)

24 l/min

24

25 l/min

25 1)

40 l/min

40 3)

50 l/min

50

100 l/min

100

Flow characteristic

08

Linear

L

Inflected characteristic curve

P 2)

09

Component series 20 ... 29 (20 ... 29: unchanged installation and connection dimensions) - Size 6

2X

Supply voltage of the control electronics

10

Direct voltage 24 V

G24

Electrical connection

11

Without mating connector; connector DIN 43563-AM6

K0

Seal material

12

NBR seals

M

13

Ruggedized design

750

1) Use only in connection with flow characteristics "P"
2) Inflected characteristic curve (inflection 60 % for NG6 with rated flows "15" and "25", otherwise inflection 40 %)
3) qv 2:1 only with rated flow = 40 l/min

For applications outside these parameters, please consult us!

general

Type

4WRPH...-750

Size

6 10

Component series

2X

Type of actuation

Proportional solenoid with position control, electrical amplifier external

Type of connection

For subplate mounting: Porting pattern according to ISO 4401

Installation position

Any

Weight

kg

2.5 7

Ambient temperature range

°C

-20 … +60

hydraulic

Type

4WRPH...-750

Size

6 10

Maximum operating pressure

bar

315

Maximum operating pressure

Port P

bar

315

Port A

bar

315

Port B

bar

315

Port T

bar

250

Maximum flow

l/min

40 100

Nominal flow

l/min

12
15
24
40
50
100

Hydraulic fluid temperature range

°C

-20 … +70

Viscosity range

Maximum admissible

mm²/s

10 … 800

Recommended

mm²/s

20 … 100

Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 1)

Class 18/16/13 according to ISO 4406 (c)

Hysteresis

%

≤ 0.2

Manufacturing tolerance

%

< 10
1) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.

hydraulic

Nominal flow

l/min

12 1) 15 1) 24 1) 40 1) 50 2) 50 3) 100 2) 100 3)

Limitation of use

Symbols C, C3, C5

bar

315 160 315 160

Symbols C1, C4

bar

315 280 250 100 250 100

Leakage flow (at 100 bar)

Linear characteristic curve “L”

l/min

< 300 - < 500 < 900 < 1200 < 1500 < 1000

Inflected characteristic curve "P"

l/min

- < 180 < 300 < 450 < 600 < 500 < 600
1) With Δp = 35 bar/control edge
2) At Δp = 35 bar/control edge, area ratio 1:1
3) At Δp = 35 bar/control edge, area ratio 2:1

electrical

Type

4WRPH...-750

Size

6 10

Power supply

Nominal voltage

V

24

Maximum solenoid current

A

2.7 3.7

Coil resistance with solenoid temperature 20 °C

Ω

2.5 2.4

Duty cycle

%

100

Maximum power consumption

VA

40