BOSCH REXROTH
0811404089
$7,221.23 USD
- BOSCH REXROTH
- Material:0811404089
- Model:4WRPH10C1B100P-2X/G24K0/M-750
Quantity in stock: 0
The Bosch Rexroth 4WRPH10C1B100P-2X/G24K0/M-750 (0811404089) is a direct operated high-response valve characterized by its servo quality performance and robust design tailored for demanding environments. This valve features electric position feedback and is designed to be actuated on one side, ensuring a 4/4 fail-safe position when deactivated. The "Ruggedized" design denotes an enhanced durability capable of withstanding up to 40 g forces, making it exceptionally reliable for applications that encounter intense vibrations or shocks. The valve's construction allows for subplate mounting, with a porting pattern that conforms to ISO 4401 standards, facilitating ease of integration into various hydraulic systems. Its specialized capabilities make it particularly well-suited for use within the wood industry or in any installation facing aggravated environmental conditions where precision and resilience are paramount. The Bosch Rexroth 4WRPH10C1B100P-2X/G24K0/M-750 valve represents a blend of high responsiveness and ruggedness, ensuring optimal performance in challenging industrial settings.
Valves of type 4WRPH-750 are direct operated high-response valve in servo quality with electric position feedback and robust design. The valves are actuated on one side and in their deactivated condition take a 4/4 fail-safe position. They are suitable for use in the wood industry and in installations with aggravated environmental conditions
|
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
10 |
11 |
12 |
13 |
||||
|
4 |
WRP |
H |
B |
‒ |
2X |
/ |
G24 |
K0 |
/ |
M |
‒ |
750 |
|
01 |
4 main ports |
4 |
|
02 |
High-response directional valve, direct operated |
WRP |
|
03 |
Control spool/sleeve |
H |
|
04 |
Size 6 |
6 |
|
Size 10 |
10 |
|
|
05 |
Symbols; for the possible version, see "Symbols/Circuit diagrams" |
C1, C3, C4, C5 |
|
Installation side of the inductive position transducer |
||
|
06 |
Valve side B (standard) (see "Symbols/Circuit diagrams") |
B |
|
Rated flow at 70 bar valve pressure differential (35 bar/control edge) |
||
|
07 |
12 l/min |
12 |
|
15 l/min |
15 1) |
|
|
24 l/min |
24 |
|
|
25 l/min |
25 1) |
|
|
40 l/min |
40 3) |
|
|
50 l/min |
50 |
|
|
100 l/min |
100 |
|
|
Flow characteristic |
||
|
08 |
Linear |
L |
|
Inflected characteristic curve |
P 2) |
|
|
09 |
Component series 20 ... 29 (20 ... 29: unchanged installation and connection dimensions) - Size 6 |
2X |
|
Supply voltage of the control electronics |
||
|
10 |
Direct voltage 24 V |
G24 |
|
Electrical connection |
||
|
11 |
Without mating connector; connector DIN 43563-AM6 |
K0 |
|
Seal material |
||
|
12 |
NBR seals |
M |
|
13 |
Ruggedized design |
750 |
| 1) | Use only in connection with flow characteristics "P" |
| 2) | Inflected characteristic curve (inflection 60 % for NG6 with rated flows "15" and "25", otherwise inflection 40 %) |
| 3) | qv 2:1 only with rated flow = 40 l/min |
For applications outside these parameters, please consult us!
general
|
Type |
4WRPH...-750 | ||
|
Size |
6 | 10 | |
|
Component series |
2X | ||
|
Type of actuation |
Proportional solenoid with position control, electrical amplifier external | ||
|
Type of connection |
For subplate mounting: Porting pattern according to ISO 4401 | ||
|
Installation position |
Any | ||
|
Weight |
kg |
2.5 | 7 |
|
Ambient temperature range |
°C |
-20 … +60 | |
hydraulic
|
Type |
4WRPH...-750 | |||
|
Size |
6 | 10 | ||
|
Maximum operating pressure |
bar |
315 | ||
|
Maximum operating pressure |
Port P |
bar |
315 | |
|
Port A |
bar |
315 | ||
|
Port B |
bar |
315 | ||
|
Port T |
bar |
250 | ||
|
Maximum flow |
l/min |
40 | 100 | |
|
Nominal flow |
l/min |
12 15 24 40 |
50 100 |
|
|
Hydraulic fluid temperature range |
°C |
-20 … +70 | ||
|
Viscosity range |
Maximum admissible |
mm²/s |
10 … 800 | |
|
Recommended |
mm²/s |
20 … 100 | ||
|
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 1) |
Class 18/16/13 according to ISO 4406 (c) | |||
|
Hysteresis |
% |
≤ 0.2 | ||
|
Manufacturing tolerance |
% |
< 10 | ||
| 1) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
hydraulic
|
Nominal flow |
l/min |
12 1) | 15 1) | 24 1) | 40 1) | 50 2) | 50 3) | 100 2) | 100 3) | |
|
Limitation of use |
Symbols C, C3, C5 |
bar |
315 | 160 | 315 | 160 | ||||
|
Symbols C1, C4 |
bar |
315 | 280 | 250 | 100 | 250 | 100 | |||
|
Leakage flow (at 100 bar) |
Linear characteristic curve “L” |
l/min |
< 300 | - | < 500 | < 900 | < 1200 | < 1500 | < 1000 | |
|
Inflected characteristic curve "P" |
l/min |
- | < 180 | < 300 | < 450 | < 600 | < 500 | < 600 | ||
| 1) | With Δp = 35 bar/control edge |
| 2) | At Δp = 35 bar/control edge, area ratio 1:1 |
| 3) | At Δp = 35 bar/control edge, area ratio 2:1 |
electrical
|
Type |
4WRPH...-750 | |||
|
Size |
6 | 10 | ||
|
Power supply |
Nominal voltage |
V |
24 | |
|
Maximum solenoid current |
A |
2.7 | 3.7 | |
|
Coil resistance with solenoid temperature 20 °C |
Ω |
2.5 | 2.4 | |
|
Duty cycle |
% |
100 | ||
|
Maximum power consumption |
VA |
40 | ||