BOSCH REXROTH
0811405061
$2,098.40 USD
- BOSCH REXROTH
- Material:0811405061
- Model:VT-VRRA1-537-20/V0
Quantity in stock: 0
The Bosch Rexroth VT-VRRA 1-537-20/V0 (0811405061) is a cutting-edge controlled output stage designed for precise closed-loop position control with PID characteristics. This advanced component is engineered to provide rapid energization and deletion, ensuring short actuating times that are crucial for dynamic system responses. It comes equipped with an enable input feature, enhancing operational safety and control. Additionally, the VT-VRRA 1-537-20/V0 boasts short-circuit-proof outputs, which significantly increase the reliability and durability of the system by protecting against potential electrical faults. The adjustable zero point functionality allows for fine-tuning and calibration of the system to meet specific application requirements, ensuring optimal performance. A particularly noteworthy feature of this product is its cable break detection capability for the actual value cable. This critical safety feature ensures that any disruption in connectivity is promptly identified, preventing inaccurate readings and potential damage to the system or process being controlled. Overall, Bosch's VT-VRRA 1-537-20/V0 (0811405061) offers a robust solution for applications requiring high precision in position control. Its fast response times and comprehensive protection features make it an ideal choice for systems where accuracy and reliability are paramount.
01 |
Valve amplifier for high-response valves with one solenoid, analog, euro-card format |
VT-VRRA1 |
02 |
For valves: 4WRPH 10…L-2X |
537 |
03 |
Component series 20 ... 29 (20 ... 29: unchanged technical data and pin assignment) |
2X |
04 |
Version: standard |
V0 |
01 |
02 |
03 |
04 |
|||
VT-VRRA1 |
‒ |
537 |
‒ |
2X |
/ |
V0 |
General
Component series |
2X | ||
Material number |
Data sheet |
1819929035 | |
Type of electronics |
Analog | ||
Design |
Euro-card |
Voltage supply
Operating voltage |
nominal |
U |
V |
24 |
Lower limit value |
UB(t)min |
V |
21 | |
Upper limit value |
UB(t)max |
V |
40 | |
Ripple 1) |
% |
< 10 | ||
Power consumption |
P |
VA |
55 | |
Current consumption |
max. |
Imax |
A |
2.7 |
1) | In case of ripple > 10 %, an upstream smoothing capacitor is required (recommendation: capacitor module VT 11110) |
Analog inputs
Command value source |
Potentiometer 10 kΩ supplied with 10 V internal reference voltage, external signal source | ||||
Command value |
Voltage |
Differential input |
U |
V |
0 ... ±10 |
Input resistance |
R |
kΩ |
≥ 100 | ||
position value 1) |
Voltage |
U |
V |
0 … ±10 |
1) | RE = 20 kΩ |
Digital inputs
Enable 1) |
On (active) |
U |
V |
8.5 ... 40 |
1) | RE = 100 kΩ |
Digital outputs
Cable break error message |
No error 1) |
UB |
V |
24 |
Error |
UB |
V |
0 |
1) | Imax = 100 mA |
Solenoid outputs
Solenoid current |
max. |
Imax |
A |
3.7 |
Solenoid output |
other properties |
Clocked current controller | ||
Cable length |
for 1.5 mm2 |
L |
m |
20 |
for 2.5 mm2 |
L |
m |
60 |
Position transducer
Line cross-section |
Position transducer line |
A |
4 x 0.5 mm2 (shielded) | |
Position transducer supply |
U |
V |
±15 |
Adjustment options
Zero point calibration setting range |
% |
± 5 |
Displays
LED display |
Green 1 |
Enable | |
Yellow 1 |
Cable break actual value | ||
Red |
UB too low |
Other information
Reference voltage |
Potentiometer supply |
U |
V |
±10 (Imax = 10 mA) |
Special features |
Short-circuit-proof outputs, cable break detection for actual value line, position control with PID behavior, fast energization and fast deletion for short actuating times | |||
Anschlussart |
32-pin male connector, DIN 41612, form F | |||
Ambient temperature range |
ϑ |
°C |
0 … 70 | |
Storage temperature range |
ϑ |
°C |
-20 … 70 | |
Weight |
m |
kg |
0.37 |
For applications outside these parameters, please consult us!
The amplifier card may only be unplugged and plugged when de-energized.
The distance to aerial lines, radios, and radar systems has to be at least 1 m.
Do not lay solenoid and signal lines near power cables.
For signal lines and solenoid conductors, we recommend using shielded cables.
The cable shield must be connected to the control cabinet extensively and as short as possible.
The valve solenoid must not be connected to free-wheeling diodes or other protection circuits.
The cable lengths and cross-sections specified in the technical data must be complied with.
Wiring information
Power zero b2 and control zero b12 or b14 or z28 must be separately led to the central ground (neutral point).