BOSCH REXROTH
0811405062
- BOSCH REXROTH
- Material:0811405062
- Model:VT-VRPA1-537-10/V0
Quantity in stock: 0
The Bosch Rexroth VT-VRPA 1-537-20/V0 (0811405062) is a sophisticated control valve designed for precise closed-loop position control with PID characteristics, ensuring accurate and responsive adjustments in various applications. This model boasts a controlled output stage that allows for rapid energization and deletion, enabling short actuating times which are critical in systems requiring quick responses. The valve also features an enable input function, providing an additional layer of operational safety and control. Incorporating short-circuit-proof outputs, the Bosch VT-VRPA 1-537-20/V0 enhances system reliability by protecting the circuitry from potential damage due to electrical mishaps. Adjustability is key with this device; it includes an adjustable zero point, allowing users to fine-tune the valve's operation according to specific requirements of their application. Moreover, the unit is equipped with cable break detection for the actual value cable. This feature serves as a diagnostic tool, alerting users to any discontinuities in the cable that could affect performance or signal transmission. This level of monitoring ensures that any potential issues can be quickly identified and addressed, minimizing downtime and maintaining consistent operation. The Bosch Rexroth VT-VRPA 1-537-20/V0 is thus well-suited for applications where precise control and rapid response are paramount. Its robust design and advanced features make it a reliable component in systems that demand high accuracy and fast actuation times without compromising on safety or adjustability.
|
01 |
Valve amplifier for high-response valves with one solenoid, analog, euro-card format |
VT-VRPA1 |
|
02 |
For valves: 5WRP10...L-2X |
537 |
|
03 |
Component series 20 ... 29 (20 ... 29: unchanged technical data and pin assignment) |
2X |
|
04 |
Version: standard |
V0 |
|
01 |
02 |
03 |
04 |
|||
|
VT-VRPA1 |
‒ |
537 |
‒ |
2X |
/ |
V0 |
General
|
Component series |
2X | ||
|
Material number |
Data sheet |
1819929035 | |
|
Type of electronics |
Analog | ||
|
Design |
Euro-card | ||
Voltage supply
|
Operating voltage |
nominal |
U |
V |
24 |
|
Lower limit value |
UB(t)min |
V |
21 | |
|
Upper limit value |
UB(t)max |
V |
40 | |
|
Ripple 1) |
% |
< 10 | ||
|
Power consumption |
P |
VA |
55 | |
|
Current consumption |
max. |
Imax |
A |
2.7 |
| 1) | In case of ripple > 10 %, an upstream smoothing capacitor is required (recommendation: capacitor module VT 11110) |
Analog inputs
|
Command value source |
Potentiometer 10 kΩ supplied with 10 V internal reference voltage, external signal source | ||||
|
Command value |
Voltage |
Differential input |
U |
V |
0 ... ±10 |
|
Input resistance |
R |
kΩ |
≥ 100 | ||
|
position value 1) |
Voltage |
U |
V |
0 … ±10 | |
| 1) | RE = 20 kΩ |
Digital inputs
|
Enable 1) |
On (active) |
U |
V |
8.5 ... 40 |
| 1) | RE = 100 kΩ |
Digital outputs
|
Cable break error message |
No error 1) |
UB |
V |
24 |
|
Error |
UB |
V |
0 |
| 1) | Imax = 100 mA |
Solenoid outputs
|
Solenoid current |
max. |
Imax |
A |
3.7 |
|
Solenoid output |
other properties |
Clocked current controller | ||
|
Cable length |
for 1.5 mm2 |
L |
m |
20 |
|
for 2.5 mm2 |
L |
m |
60 |
Position transducer
|
Line cross-section |
Position transducer line |
A |
4 x 0.5 mm2 (shielded) | |
|
Position transducer supply |
U |
V |
±15 | |
Adjustment options
|
Zero point calibration setting range |
% |
± 5 |
Displays
|
LED display |
Green 1 |
Enable | |
|
Yellow 1 |
Cable break actual value | ||
|
Red |
UB too low |
Other information
|
Reference voltage |
Potentiometer supply |
U |
V |
±10 (Imax = 10 mA) |
|
Special features |
Short-circuit-proof outputs, cable break detection for actual value line, position control with PID behavior, fast energization and fast deletion for short actuating times | |||
|
Anschlussart |
32-pin male connector, DIN 41612, form F | |||
|
Ambient temperature range |
ϑ |
°C |
0 … 70 | |
|
Storage temperature range |
ϑ |
°C |
-20 … 70 | |
|
Weight |
m |
kg |
0.37 | |
For applications outside these parameters, please consult us!
The amplifier card may only be unplugged and plugged when de-energized.
The distance to aerial lines, radios, and radar systems has to be at least 1 m.
Do not lay solenoid and signal lines near power cables.
For signal lines and solenoid conductors, we recommend using shielded cables.
The cable shield must be connected to the control cabinet extensively and as short as possible.
The valve solenoid must not be connected to free-wheeling diodes or other protection circuits.
The cable lengths and cross-sections specified in the technical data must be complied with.
Wiring information
Power zero b2 and control zero b12 or b14 or z28 must be separately led to the central ground (neutral point).