BOSCH REXROTH
0811405101
$1,715.70 USD
- BOSCH REXROTH
- Material:0811405101
- Model:VT-VRPA1-527-10/V0/PV-RTP
Quantity in stock: 0
The Bosch Rexroth VT-VRPA 1-527-1X/V0/PV-RTP (0811405101) is a sophisticated hydraulic amplifier designed for precise control in hydraulic systems. It features a closed-loop position control with PID characteristics, ensuring high accuracy and stability in the operation of hydraulic actuators. The device is engineered to provide fast energization and deletion, resulting in exceptionally short actuating times that are critical for dynamic system responses. Equipped with an enable input, the Bosch VT-VRPA 1-527-1X/V0/PV-RTP ensures safe operation by allowing the system to activate the output stage only when necessary. Its outputs are short-circuit-proof, providing additional protection against electrical faults and enhancing the reliability of the entire system. For customization and optimization of performance, this model offers adjustable ramp time, sensitivity, and zero point. These features allow for fine-tuning to match specific application requirements, ensuring optimal performance across a range of operating conditions. Moreover, the unit includes cable break detection for the actual value cable. This safety feature ensures immediate notification and response in case of wiring issues, preventing potential damage or failure in critical applications. Overall, the Bosch VT-VRPA 1-527-1X/V0/PV-RTP is designed to deliver precise control and fast response times in hydraulic systems while maintaining safety and reliability through its robust protection features.
01 |
Valve amplifier for high-response valves with one solenoid, analog, euro-card format |
VT-VRPA1 |
02 |
For valves: DBETFX, DREB6X, 4WRP6EA, 3FREZ |
527 |
03 |
Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions) |
1X |
04 |
Version: standard |
V0 |
05 |
Option: Pressure valves |
PV |
Option: Throttle/flow control valves |
QV |
|
06 |
Adjustable ramp that can be switched off |
RTP |
01 |
02 |
03 |
04 |
05 |
06 |
|||||
VT-VRPA1 |
‒ |
527 |
‒ |
1X |
/ |
V0 |
/ |
‒ |
RTP |
Position transducer
Cable length |
L |
50 m at 100 pF/m |
Supplementary information
Reference voltage |
Potentiometer supply |
U |
V |
10 (Imax = 50 mA) |
Special features |
Short-circuit-proof outputs, cable break detection for actual value line, position control with PID behavior, fast energization and fast deletion for short actuating times | |||
Anschlussart |
32-pin male connector, DIN 41612, form F | |||
Ambient temperature range |
ϑ |
°C |
0 … 70 | |
Storage temperature range |
ϑ |
°C |
-20 … 70 | |
Weight |
m |
kg |
0.36 |
Anzeigen
LED display |
Green 1 |
Enable | |
Yellow 1 |
Cable break actual value | ||
Yellow 2 |
Ramp off | ||
Red |
UB too low |
Adjustment options
Zero point calibration |
% |
± 10 | ||
Range sensitivity adjustment |
Setting condition |
% |
50 ... 100 | |
Ramp time up/down |
Ramp 1 |
t |
s |
0.05 … 5 |
Solenoid outputs
Solenoid current |
max. |
Imax |
A |
2.7 |
Power |
P |
VA |
25 | |
Solenoid output |
other properties |
clocked | ||
Cable length |
for 1.5 mm2 |
m |
20 | |
for 2.5 mm2 |
m |
50 |
Analog outputs
Test point 1) |
Actual value |
0 ... 10 |
1) | 0 V at solenoid current = 0 ( output stage not enabled), 10 V at solenoid current = maximum |
Analog inputs
Command value source |
Potentiometer 1 kΩ supplied with 10 V internal reference voltage, external signal source | ||||
Command value |
Voltage (differential input) |
U |
V |
0 ... 10 | |
Voltage |
grounded on one side, first input |
Ucommand |
V |
0 … 10 | |
Voltage |
grounded on one side, second input |
Ucommand |
V |
0 … 10 | |
Actual value valve |
Voltage |
U |
10.2 (7.8 kHz) |
Voltage supply
Operating voltage |
nominal |
U |
V |
24 |
Lower limit value |
UB(t)min |
V |
21 | |
Upper limit value |
UB(t)max |
V |
40 | |
Ripple 1) |
% |
< 10 | ||
Power consumption |
max. |
Smax |
VA |
35 |
Current consumption |
max. |
Imax |
A |
1.5 |
1) | In case of ripple > 10 %, an upstream smoothing capacitor is required (recommendation: capacitor module VT 11110) |
Digital outputs
Cable break error message |
No error 1) |
U |
V |
24 V |
Error |
U |
V |
0 V |
1) | Imax = 100 mA |
Digital inputs
Enable |
On (active) |
U |
V |
8.5 ... 40 |
External ramp switch-off |
Without ramp |
U |
V |
8.5 ... 40 |
With ramp |
U |
V |
8.5 ... 40 |
General
Component series |
1X | ||
Material number |
Data sheet |
1819929063 | |
Type of electronics |
Analog | ||
Design |
Euro-card |
For applications outside these parameters, please consult us!
2/2 directional seat valve (“PK”) and 3/2 directional seat valve (“UK”)
Dimensions in mm
Dimensions in mm
The amplifier card may only be unplugged and plugged when de-energized.
The distance to aerial lines, radios, and radar systems has to be at least 1 m.
Do not lay solenoid and signal lines near power cables.
For signal lines and solenoid conductors, we recommend using shielded cables.
The cable shield must be connected to the control cabinet extensively and as short as possible.
The valve solenoid must not be connected to free-wheeling diodes or other protection circuits.
The cable lengths and cross-sections specified in the technical data must be complied with.
Wiring information
Power zero b2 and control zero b12 are to be bridged.
If the power supply unit is < 1 m away, directly to DIN connector.
In case of distances > 1 m, lead the control zero separately to the ground.
Information on ramp use
Ramp ON: No signal at b20.
Ramp OFF: 8.5...40 V at b20 or connection between b22 and b20.
In case of ramp OFF or cable break, any ramp started before will be canceled. Transition to the signal end value is realized in one step.