You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

BOSCH REXROTH
0811405103


$1,760.59 USD
  • BOSCH REXROTH
  • Material:0811405103
  • Model:VT-VRPA1-527-10/V0/QV-RTP

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Bosch Rexroth directly.***
The Bosch Rexroth VT-VRPA1-527-1X/V0/QV-RTP (0811405103) is a sophisticated control valve designed for precise closed-loop position control with PID characteristics, ensuring high accuracy and dynamic response in various applications. This model features a controlled output stage that allows for rapid energization and deletion, resulting in exceptionally short actuating times suitable for systems requiring quick responses. Equipped with an enable input, the valve ensures safe operation by allowing the system to activate the valve only when necessary. Its short-circuit-proof outputs add an extra layer of protection against electrical faults, enhancing its reliability and longevity in demanding environments. The adjustable ramp time, sensitivity, and zero point provide users with the flexibility to fine-tune the valve's performance according to specific requirements. These adjustments can be critical in achieving optimal system efficiency and precision. Moreover, the Bosch VT-VRPA1-527-1X/V0/QV-RTP includes cable break detection for the actual value cable, a feature that promptly alerts users to any disruptions or failures in signal transmission. This immediate detection helps prevent potential inaccuracies or downtime due to cable issues. Overall, this model is engineered to offer robust performance and precise control in applications where fast actuation and high reliability are paramount. Its advanced features ensure it can be tailored to meet the nuanced demands of specialized systems without compromising on safety or quality.

01

Valve amplifier for high-response valves with one solenoid, analog, euro-card format

VT-VRPA1

02

For valves: DBETFX, DREB6X, 4WRP6EA, 3FREZ

527

03

Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions)

1X

04

Version: standard

V0

05

Option: Pressure valves

PV

Option: Throttle/flow control valves

QV

06

Adjustable ramp that can be switched off

RTP

01

02

03

04

05

06

VT-VRPA1

527

1X

/

V0

/

RTP

Position transducer

Cable length

L

50 m at 100 pF/m

Supplementary information

Reference voltage

Potentiometer supply

U

V

10 (Imax = 50 mA)

Special features

Short-circuit-proof outputs, cable break detection for actual value line, position control with PID behavior, fast energization and fast deletion for short actuating times

Anschlussart

32-pin male connector, DIN 41612, form F

Ambient temperature range

ϑ

°C

​0 … ​70

Storage temperature range

ϑ

°C

-20 … ​70

Weight

m

kg

0.36

Anzeigen

LED display

Green 1

Enable

Yellow 1

Cable break actual value

Yellow 2

Ramp off

Red

UB too low

Adjustment options

Zero point calibration

%

± 10

Range sensitivity adjustment

Setting condition

%

50 ... 100

Ramp time up/down

Ramp 1

t

s

0.05 … 5

Solenoid outputs

Solenoid current

max.

Imax

A

2.7

Power

P

VA

25

Solenoid output

other properties

clocked

Cable length

for 1.5 mm2

m

20

for 2.5 mm2

m

50

Analog outputs

Test point 1)

Actual value

0 ... 10
1) 0 V at solenoid current = 0 ( output stage not enabled), 10 V at solenoid current = maximum

Analog inputs

Command value source

Potentiometer 1 kΩ supplied with 10 V internal reference voltage, external signal source

Command value

Voltage (differential input)

U

V

​0 ... ​10

Voltage

grounded on one side, first input

Ucommand

V

​0 … ​10

Voltage

grounded on one side, second input

Ucommand

V

​0 … ​10

Actual value valve

Voltage

U

10.2 (7.8 kHz)

Voltage supply

Operating voltage

nominal

U

V

24

Lower limit value

UB(t)min

V

21

Upper limit value

UB(t)max

V

40

Ripple 1)

%

< 10

Power consumption

max.

Smax

VA

35

Current consumption

max.

Imax

A

1.5
1) In case of ripple > 10 %, an upstream smoothing capacitor is required (recommendation: capacitor module VT 11110)

Digital outputs

Cable break error message

No error 1)

U

V

24 V

Error

U

V

0 V
1) Imax = 100 mA

Digital inputs

Enable

On (active)

U

V

8.5 ... 40

External ramp switch-off

Without ramp

U

V

8.5 ... 40

With ramp

U

V

8.5 ... 40

General

Component series

1X

Material number

Data sheet

1819929063

Type of electronics

Analog

Design

Euro-card

For applications outside these parameters, please consult us!

technical illustration-0811405103-Controlled output stage Closed-loop position control with PID characteristics Fast energization and fast deletion for short actuating times Enable input Short-circuit-proof outputs Adjustable ramp time, sensitivity and zero point Cable break detection for actual value cable
technical illustration-0811405103-Controlled output stage Closed-loop position control with PID characteristics Fast energization and fast deletion for short actuating times Enable input Short-circuit-proof outputs Adjustable ramp time, sensitivity and zero point Cable break detection for actual value cable

2/2 directional seat valve (“PK”) and 3/2 directional seat valve (“UK”)

Dimensions in mm

technical illustration-0811405103-Controlled output stage Closed-loop position control with PID characteristics Fast energization and fast deletion for short actuating times Enable input Short-circuit-proof outputs Adjustable ramp time, sensitivity and zero point Cable break detection for actual value cable

Dimensions in mm

technical illustration-0811405103-Controlled output stage Closed-loop position control with PID characteristics Fast energization and fast deletion for short actuating times Enable input Short-circuit-proof outputs Adjustable ramp time, sensitivity and zero point Cable break detection for actual value cable

The amplifier card may only be unplugged and plugged when de-energized.

The distance to aerial lines, radios, and radar systems has to be at least 1 m.

Do not lay solenoid and signal lines near power cables.

For signal lines and solenoid conductors, we recommend using shielded cables.
The cable shield must be connected to the control cabinet extensively and as short as possible.

The valve solenoid must not be connected to free-wheeling diodes or other protection circuits.

The cable lengths and cross-sections specified in the technical data must be complied with.

Wiring information

Power zero b2 and control zero b12 are to be bridged.
If the power supply unit is < 1 m away, directly to DIN connector.
In case of distances > 1 m, lead the control zero separately to the ground.

Information on ramp use

Ramp ON: No signal at b20.

Ramp OFF: 8.5...40 V at b20 or connection between b22 and b20.

In case of ramp OFF or cable break, any ramp started before will be canceled. Transition to the signal end value is realized in one step.