BOSCH REXROTH
R900508670
- BOSCH REXROTH
- Material:R900508670
- Model:Z2S16-4-5X/V
Due to extremely high demand, please call 877-366-7226 for availability
The Bosch Rexroth Z2S16-4-5X/V (R900508670) is a high-quality isolator valve designed for leak-free blocking of one or two actuator ports, ensuring reliable operation even after extended periods of inactivity. This valve allows for free flow in the direction A to A or B to B while blocking the flow in the opposite direction. The innovative design includes a control spool that, when activated, opens a ball seat valve and lifts the poppet off its seat, allowing hydraulic fluid to flow from B to B. The Z2S16-4-5X/V features a preopening function that damps decompression of pressurized liquid, thereby minimizing potential switching shocks. Its two-stage setup with an increased control open ratio ensures that even low pilot pressures can be securely unloaded. This sandwich plate valve is suitable for vertical stacking applications and adheres to the ISO porting pattern standard. The valve's design also includes various cracking pressures and offers optional features for enhanced performance. Installation sets for the check valve are available individually, providing flexibility for system integration. The corrosion-protected construction ensures durability and longevity in harsh environments. With a maximum operating pressure of up to 350 bar and a maximum flow rate of up to 80 liters per minute, the Bosch Rexroth Z2S16-4-5X/V is well-suited for demanding hydraulic applications requiring precise control over fluid flow. Its robust design and precise engineering make it an essential component in advanced hydraulic systems where leak-free operation and shock minimization are crucial.
The isolator valve type Z2S is a releasable check valve in sandwich plate design.
It is used for the leakage-free blocking of one or two actuator ports, also in case of longer standstill times.
In direction A① to A② or B① to B②, there is a free flow; in the opposite direction, the flow is blocked.
If, for example, there is a flow through the valve in direction A① to A②, the control spool (1) is moved in the direction of the B side, opens the ball seat valve (2) and then pushes the poppet (3) off its seat. Hydraulic fluid can now flow from B➁ to B➀.
In order to allow the ball seat valve (2) to be safely closed, the control spool (1) must be hydraulically unloaded (see circuit example).
Pre-opening
Due to the pre-opening, there is a damped decompression of the pressurized liquid. Thus, possible switching shocks are avoided. The two-stage set-up with an increased control open ratio means even low pilot pressure can be unloaded securely.Type Z2S 16 ‒…
Type Z2S 16 A…
Type Z2S 16 A…SO40
Type Z2S 16 A…SO60
Circuit example, schematic
|
1 |
Control spool, area A2 |
|
2 |
Ball, area A3 |
|
3 |
Poppet, area A1 |
|
4 |
Stop |
|
5 |
Control spool, area A4 |
|
① |
component side |
|
② |
plate side |
|
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
||
|
Z2S |
16 |
– |
5X |
/ |
* |
|
01 |
Check valve, Sandwich plate design |
Z2S |
|
02 |
Size 16 |
16 |
|
Leakage-free blocking |
||
|
03 |
In channel A and B |
– |
|
In channel A |
A |
|
|
In channel B |
B |
|
|
Cracking pressure |
||
|
04 |
3 bar |
1 |
|
5 bar |
2 |
|
|
7,5 bar |
3 |
|
|
10 bar |
4 |
|
|
05 |
Component series 50 ... 59 (50 ... 59: unchanged technical data and pin assignment) |
5X |
|
Seal material |
||
|
06 |
NBR seals |
no code |
|
FKM seals |
V |
|
|
Observe compatibility of seals with hydraulic fluid used. (Other seals upon request) |
||
|
Corrosion resistance (outside; thick film passivated according to DIN 50979 Fe//Zn8//Cn//T0) |
||
|
07 |
None (valve housing primed) |
no code |
|
Improved corrosion protection (240 h salt spray test according to EN ISO 9227) |
J3 |
|
|
Special version |
||
|
08 |
Standard |
no code |
|
Control open by external port G1/4 (only version "A" and "B") |
SO40 |
|
|
Control spool unloaded to port T |
SO60 |
|
|
09 |
Further details in the plain text |
* |
For applications outside these parameters, please consult us!
general
|
Size |
16 | ||
|
Weight |
kg |
6.5 | |
|
Installation position |
any | ||
|
Ambient temperature range |
NBR seals |
°C |
-30 … +80 |
|
FKM seals |
°C |
-20 … +80 | |
|
MTTFD values according to EN ISO 13849 |
Years |
150 1) | |
| 1) | For further details, see data sheet 08012 |
hydraulic
|
Size |
16 | ||
|
Maximum operating pressure |
bar |
315 | |
|
Cracking pressure (in free direction) |
See characteristic curves | ||
|
Maximum flow |
l/min |
300 | |
|
Direction of flow |
see symbols | ||
|
Hydraulic fluid |
see table "Hydraulic fluid" | ||
|
Hydraulic fluid temperature range (at the valve working ports) |
NBR seals |
°C |
-30 … +80 |
|
FKM seals |
°C |
-20 … +80 | |
|
Viscosity range |
mm²/s |
2.8 … 500 | |
|
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 1) |
Class 20/18/15 | ||
|
Area ratio |
With pre-opening |
A3/A2 ~ 1/12 (see sectional drawing) | |
|
Version "SO60" |
A1/A4 ~ 1/7 (see sectional drawing) | ||
| 1) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
|
Hydraulic fluid |
Classification |
Suitable sealing materials |
Standards |
Data sheet |
|
|
Mineral oils |
HL, HLP, HLPD, HVLP, HVLPD |
NBR, FKM |
DIN 51524 |
90220 |
|
|
Bio-degradable |
Insoluble in water |
HETG 1) |
NBR, FKM |
ISO 15380 |
90221 |
|
HEES 1) |
FKM |
||||
|
Soluble in water |
HEPG 1) |
FKM |
ISO 15380 |
||
|
Flame-resistant |
Water-free |
HFDU (glycol base) |
FKM |
ISO 12922 |
90222 |
|
HFDU (ester base) 1) |
FKM |
||||
|
HFDR |
FKM |
||||
|
Containing water |
HFC (Fuchs Hydrotherm 46M, Petrofer Ultra Safe 620) 1) |
NBR |
ISO 12922 |
90223 |
|
|
Important information on hydraulic fluids: There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.). The ignition temperature of the hydraulic fluid used must be 50 K higher than the maximum surface temperature. Flame-resistant - containing water: Maximum pressure differential 210 bar, otherwise, increased cavitation erosion Life cycle as compared to operation with mineral oil HL, HLP 30 … 100%. Maximum hydraulic fluid temperature 60 °C Bio-degradable and flame-resistant – containing water: If this hydraulic fluid is used, small amounts of dissolved zinc may get into the hydraulic system. |
|||||
| 1) | Not recommended for corrosion-protected version "J3" (contains zinc) |
Notice:
Selection of optimal sealing material (see "Type code") also depends on the type of hydraulic fluid used.
(measured with HLP46, ϑOil = 40 ±5 °C)
Δp-qV characteristic curves
|
① |
component side |
|
② |
plate side |
Version "A"
Version "-"
Version "B"
Version "A…SO40"
Version "A…SO60"
Dimensions in mm
|
|
Required surface quality of the valve contact surface |
|
Version |
Cracking pressure in bar |
Leakage-free blocking in channel |
L1 in mm |
L2 in mm |
|
"no code" |
3; 5 |
„–“ |
10 |
10 |
|
7,5; 10 |
„–“ |
36,5 |
36,5 |
|
|
3; 5 |
A |
10 |
8,5 |
|
|
3; 5 |
B |
8,5 |
10 |
|
|
7,5; 10 |
A |
36,5 |
8,5 |
|
|
B |
8,5 |
36,5 |
||
|
„SO40“ |
3; 5 |
A, B |
10 |
10 |
|
7,5; 10 |
A |
36,5 |
10 |
|
|
B |
10 |
36,5 |
||
|
„SO60“ |
3; 5 |
A |
10 |
8,5 |
|
3; 5 |
B |
8,5 |
10 |
|
|
7,5; 10 |
A |
36,5 |
8,5 |
|
|
B |
8,5 |
36,5 |
|
① |
component side |
|
② |
plate side |
|
1 |
Name plate |
|
2 |
Through holes for valve mounting |
|
3 |
Identical seal rings for ports A, B, P and T |
|
4 |
Identical seal rings for ports X, Y, L |
|
5 |
Locking pins |
|
6 |
Locating holes |
|
7 |
Porting pattern according to ISO 4401-07-0-05 |
|
8 |
Plug screw SW41, Tightening torque MA = 70 Nm |
Valve mounting screws (separate order)
|
Size |
Quantity |
Hexagon socket head cap screws |
Material number |
|
16 |
4 |
ISO 4762 - M10 10.9 |
- |
|
2 |
ISO 4762 - M6 10.9 |
- |
Notice: