BOSCH REXROTH
R900511171
- BOSCH REXROTH
- Material:R900511171
- Model:DB 10 K7-4X/50YV
Due to extremely high demand, please call 877-366-7226 for availability
The Bosch Rexroth DB 10 K7-4X/50YV (R900511171) is a pilot-operated pressure relief valve designed for block installation and system pressure limitation. This screw-in cartridge valve operates with a maximum pressure of 350 bar (5076 psi) and can handle a maximum flow of 50 l/min (13.2 gpm). It features an Mx cavity for installation and utilizes FKM as its sealing material, ensuring compatibility with hydraulic fluids such as HL, HLP, HEES, and HEPG. The valve's functionality is based on its poppet type spool that responds to system pressure changes. In its default state, the valve remains closed until the pressure at the main port activates the spool through a series of pilot nozzles and poppets. Once the preset pressure threshold is surpassed, the pilot poppet opens allowing hydraulic fluid to flow and adjust the spool position accordingly, thereby regulating the system pressure to the desired level set by the user. This model comes equipped with various adjustment options including a rotary knob with scale for precise control over pressure settings. The DB.K series valves are recognized for their reliability in maintaining system pressures within safe operating limits. The DB 10 K7-4X/50YV is characterized by an internal pilot oil supply and external pilot oil return mechanism. It features two ports for hydraulic fluid passage and has been engineered to minimize any counter pressures at main port 2 that could affect the set pressure values. With its robust design tailored for high-pressure applications, this Bosch Rexroth relief valve ensures efficient operation in hydraulic systems requiring precise pressure control. Its compact size and direct cartridge style allow for seamless integration into various hydraulic circuits while providing top-tier performance synonymous with Bosch Rexroth's engineering standards.
Unpacked Weight: 0.4 kg
Pressure valves type DB..K.. are pilot-operated pressure relief valves for block design installation. They are used for system pressure limitation. The system pressure can be set via the adjustment type (4).
In the initial position the valves are closed. The pressure in main port 1 acts on the spool (1). At the same time, pressure is applied to the spring-loaded side of the spool (1) via nozzle (2) and to the pilot poppet (6) via nozzle (3). If the pressure in main port 1 exceeds the value set at spring (5), the pilot poppet (6) opens. Hydraulic fluid flows from the spring-loaded side of the spool (1) via nozzle (3) and channel (7) into the main port 3. The resulting pressure drop moves the spool (1) and thus opens the connection from main port 1 to 2 while maintaining the pressure set at spring (5).
Die pilot oil return from the two spring chambers is effected externally, via main port 3.
Notice!
Counter pressures (main port 3) add up to the set pressure.
Type DB 10 K2-4X/.YV
| Screw-in cartridge valve |
| Maximum operating pressure 315 bar (4568 psi) |
| Maximum flow 100 l/min (26 gpm) |
| Cavity M24x1 |
| Max. pressure | 315 |
| Adjustment options | Rotary knob with scale |
| Product family classification | Pressure relief valve, pilot operated |
| Productgroup ID | 9,10,11,12,13,14 |
| Product family type | DB.K |
| Ports number | 3 |
| Sealing material | FKM |
| Cavity | M24x1 |
| Product type | DB.K |
| Max. flow | 100 |
| Type of connection | Screw-in cartridge valve |
| Nominal flow | 100 |
| Direct - Pilot | Pilot operated |
| Product family | Relief |
| Pilot oil supply and return | Internal pilot oil supply, external pilot oil return |
| Spool Poppet | Poppet type |
| Weight | 0.4 |
| Hydraulic fluid | HL,HLP,HEES,HEPG |
|
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
||
|
DB |
K |
– |
4X |
/ |
Y |
V |
* |
|
01 |
Pressure relief valve, pilot controlled |
DB |
|
02 |
Size 6 |
6 |
|
Size 10 |
10 |
|
|
03 |
Cartridge valve |
K |
|
Adjustment type |
||
|
04 |
Rotary knob |
1 |
|
Sleeve with hexagon and protective cap |
2 |
|
|
Lockable rotary knob with scale |
3 1) |
|
|
Rotary knob with scale |
7 |
|
|
05 |
Component series 40 … 49 (40 … 49: unchanged installation and mounting dimensions) |
4X |
|
Pressure rating |
||
|
06 |
Set pressure up to 50 bar |
50 |
|
Set pressure up to 100 bar |
100 |
|
|
Set pressure up to 200 bar |
200 |
|
|
Set pressure up to 315 bar |
315 |
|
|
07 |
Internal pilot oil supply, external pilot oil return |
Y |
|
Seal material |
||
|
08 |
FKM seals (other seals upon request) |
V |
|
Observe compatibility of seals with hydraulic fluid used. |
||
|
09 |
Further details in the plain text |
* |
| 1) H-key with material no. R900008158 is included in the scope of delivery. |
general
|
Size |
6 | 10 | |
|
Weight (approx.) |
kg |
0.15 | 0.2 |
|
Installation position |
any | ||
|
Ambient temperature range |
°C |
-20 … +80 | |
hydraulic
|
Size |
6 | 10 | ||
|
Maximum operating pressure 1) |
Port P |
bar |
315 | |
|
Maximum adm. counter pressure 1) |
Port T |
bar |
315 | |
|
Port Y |
bar |
315 | ||
|
Maximum set pressure |
Port P |
bar |
50 100 200 315 |
|
|
Maximum flow |
l/min |
60 | 100 | |
|
Hydraulic fluid |
see table | |||
|
Hydraulic fluid temperature range |
°C |
-20 … +80 | ||
|
Viscosity range |
mm²/s |
10 … 800 | ||
|
Maximum admissible degree of contamination of the hydraulic fluid 2) |
Class 20/18/15 according to ISO 4406 (c) | |||
| 1) | Attention! The maximum operating pressure is added up from the set pressure and the return flow pressure. |
| 2) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
|
Hydraulic fluid |
Classification |
Suitable sealing materials |
Standards |
|
|
Mineral oil |
HL, HLP |
FKM, NBR |
DIN 51524 |
|
|
Bio-degradable |
Insoluble in water |
HEES (synthetic esters) |
FKM |
VDMA 24568 |
|
HETG (rape seed oil) |
FKM, NBR |
|||
|
Soluble in water |
HEPG (polyglycols) |
FKM |
VDMA 24568 |
|
|
Other hydraulic fluids on request |
||||
For applications outside these parameters, please consult us!
(measured with HLP46, ϑOil = 40 ±5 °C)
NG6
pE-qV characteristic curves
NG6
pE min-qV characteristic curves
Attention!
The characteristic curves apply for output pressure = zero in the entire flow range!
NG10
pE-qV characteristic curves
NG10
pE min-qV characteristic curves
|
➀ |
Main port 1 (P) |
|
➁ |
Main port 2 (T) |
|
➂ |
Main port 3 (Y) |
NG6
Dimensions in mm
|
1 |
Adjustment type "1" |
|
2 |
Adjustment type "2" |
|
3 |
Adjustment type "3" |
|
4 |
Adjustment type "7" |
|
5 |
Space required to remove the key |
|
6 |
Lock nut SW24 |
|
7 |
Hexagon SW10 |
|
8 |
Wrench size SW24, tightening torque for screw-in MA = 50 Nm |
|
➀ |
Main port 1 (P) |
|
➁ |
Main port 2 (T) |
|
➂ |
Main port 3 (Y) |
|
LS |
Location shoulder |
|
➀ |
Main port 1 (P) |
|
➁ |
Main port 2 (T), can optionally be arranged at the circumference |
|
➂ |
Main port 3 (Y) |
|
LS |
Location shoulder |
NG6; 3 main ports; thread M20 x 1
Dimensions in mm
|
1 |
Adjustment type "1" |
|
2 |
Adjustment type "2" |
|
3 |
Adjustment type "3" |
|
4 |
Adjustment type "7" |
|
5 |
Space required to remove the key |
|
6 |
Lock nut SW24 |
|
7 |
Hexagon SW10 |
|
8 |
Wrench size SW24, tightening torque for screw-in MA = 50 Nm |
|
➀ |
Main port 1 (P) |
|
➁ |
Main port 2 (T) |
|
➂ |
Main port 3 (Y) |
|
LS |
Location shoulder |
|
➀ |
Main port 1 (P) |
|
➁ |
Main port 2 (T), can optionally be arranged at the circumference |
|
➂ |
Main port 3 (Y) |
|
LS |
Location shoulder |
NG10
Dimensions in mm
|
1 |
Adjustment type "1" |
|
2 |
Adjustment type "2" |
|
3 |
Adjustment type "3" |
|
4 |
Adjustment type "7" |
|
5 |
Space required to remove the key |
|
6 |
Lock nut SW24 |
|
7 |
Hexagon SW10 |
|
8 |
Hexagon SW30, tightening torque for screw-in MA = 50 Nm |
|
➀ |
Main port 1 (P) |
|
➁ |
Main port 2 (T) |
|
➂ |
Main port 3 (Y) |
|
LS |
Location shoulder |
Mounting cavity – NG10; 3 main ports; thread M20 x 1
Dimensions in mm
|
➀ |
Main port 1 (P) |
|
➁ |
Main port 2 (T), can optionally be arranged at the circumference |
|
➂ |
Main port 3 (Y) |
|
LS |
Location shoulder |