BOSCH REXROTH
R900618980
- BOSCH REXROTH
- Material:R900618980
- Model:VT-DFPC-A-2X/G24K0/0A0V/V
Quantity in stock: 0
The Bosch Rexroth VT-DFPC-A-2X/G24K0/0A0V/V (R900618980) is a highly sophisticated pilot valve designed for precise pressure and flow control within hydraulic systems. This component is specifically engineered to operate through a proportional solenoid that benefits from electrical feedback, ensuring responsive and accurate control. The model is equipped with integrated, digital control electronics known as VTDFPC, which are tailored for the SYHDFEC system and feature a CANBus interface for seamless communication and configuration. The valve's robust design allows it to handle a maximum operating pressure bar, highlighting its capability to function reliably in demanding applications. This model exemplifies Bosch Rexroth's commitment to innovation in hydraulic system components, providing users with advanced functionality that enhances system performance and efficiency. The VT-DFPC-A-2X/G24K0/0A0V/V is an essential part of a comprehensive solution for controlling fluid power in various applications requiring precise modulation of pressure and flow. Its integration into hydraulic circuits will enable users to achieve optimal control with high levels of accuracy and repeatability, which are critical in modern industrial processes.
|
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
10 |
11 |
||||||
|
VT-DFPC |
- |
- |
2X |
/ |
G24 |
K0 |
/ |
A |
0 |
/ |
- |
* |
|
Series |
|||||||
|
01 |
Pilot valve with integrated digital electronics |
VT-DFPC |
|||||
|
Spool design |
|||||||
|
02 |
Standard (not for HFC fluids) |
A |
|||||
|
2-groove spool (only for replacement requirement) |
B |
||||||
|
4-groove spool (e.g. for HFC fluids) |
C |
||||||
|
03 |
Component series |
2X |
|||||
|
04 |
Direct voltage 24 V |
G24 |
|||||
|
05 |
Connector (without mating connector) 1) |
K0 |
|||||
|
Installation orientation connector (VT-DFP) and/or integrated electronics (see also comment on feature 6) |
|||||||
|
06 |
radially to the pump axis |
0 |
|||||
|
folded 90° in the direction of the subplate with counterclockwise direction of rotation |
1 |
||||||
|
folded 90° in the direction of the subplate with clockwise direction of rotation |
2 |
||||||
|
Additional functions: Closed-loop control |
A |
B |
C |
D |
R |
||
|
07 |
Standard |
● |
A |
||||
|
Electronics assembly, option |
|||||||
|
08 |
Standard |
● |
0 |
||||
|
Actual pressure value input |
Plug-in connector |
||||||
|
09 |
Current input 4...20 mA |
X1 |
C |
||||
|
Voltage input 0...10 V (standard) |
X1 |
V |
|||||
|
Voltage input 1...10 V |
X1 |
E |
|||||
|
Voltage input 0.5..5 V (Standard) 2) |
X2 |
F |
|||||
|
10 |
FKM seals suitable for mineral oils (HL, HLP) according to DIN 51524 and HFC fluids 3) |
V |
|||||
|
11 |
Further details in the plain text e. g. SO variant |
* |
|||||
|
1 |
Material number |
|
2 |
Serial number |
|
3 |
Date of production |
|
4 |
Production order number |
|
5 |
Type designation |
|
● |
available |
|
- |
not available |
Note on feature 6: Installation orientation of the valve electronics
|
Clockwise direction of rotation, installation orientation 0 |
Clockwise direction of rotation, installation orientation 2 |
Counterclockwise direction of rotation, installation orientation 0 |
Counterclockwise direction of rotation, installation orientation 1 |
|
|
|
|
| 1) | Connector dependent on the valve type (see "Technical data" and "Electrical connection”). |
| 2) | With the SY(H)DFEn control system with analog interfaces, the plug-in connector X2 can not be used as actual pressure value input. Thus, a separate pressure transducer has to be used and connected to plug-in connector X1 in this case. |
| 3) | Only in connection with SYHDFE and spool design C (feature 2). |
|
1 |
Material number |
|
2 |
Serial number |
|
3 |
Date of production |
|
4 |
Production order number |
|
5 |
Type designation |
|
● |
available |
|
- |
not available |
Accessories
Version 10/2011, enquire availability
|
Accessories |
Material number |
Data sheet |
|
Mating connector 12-pole for central connection X1 without cable (assembly kit) |
R900884671 |
08006 |
|
Mating connector 12-pole for central connection X1 with cable set 2 x 5 m |
R900032356 |
|
|
Mating connector 12-pole for central connection X1 with cable set 2 x 20 m |
R900860399 |
|
|
Test device VT-PDFE-1-1X/V0/0 for SY(H)DFEE and SY(H)DFEC |
R900757051 |
29689-B |
|
Compact power supply unit VT-NE32-1X |
R900080049 |
29929 |
|
Converter USB serial for laptops without serial interface VT-ZKO-USB/S-1-1X/V0/0 |
R901066684 |
|
|
Cable for the connection of a Win-PED PC (RS232) at the interface X2, length 3 m |
R901156928 |
|
|
T connector for the simultaneous connection of a WIN-PED PC (RS232) and use of the input at connector X2 |
R901117164 |
|
|
Mating connector for interface X3, M12, straight, can be connected independently, 5-pole, shielded, A coded, cable diameter 6 ... 8 mm |
R901076910 |
mechanic and hydraulic
|
Mass |
Pump without through-drive incl. pilot valve |
m |
kg |
2.25 |
|
Hydraulic fluid |
Mineral oil (HL, HLP) according to DIN 51524; HFC fluids only in connection with SYHDFE control system and C spool design C (feature 2 of ordering code) | |||
|
Hydraulic fluid temperature range |
ϑ |
°C |
-20 … +70 | |
|
Maximum admissible degree of contamination of the hydraulic fluid according to ISO 4406 |
Class 18/16/13 (for particle size ≤ 4/6/14 μm) | |||
mechanic and hydraulic
|
Weight without filling quantity |
m |
kg |
2.25 |
|
Hydraulic fluid |
Mineral oil (HL, HLP) according to DIN 51524; HFC fluids only in connection with SYHDFE control system and C spool design C (feature 2 of ordering code) | ||
|
Hydraulic fluid temperature range |
ϑ |
°C |
-20 … +70 |
|
Maximum admissible degree of contamination of the hydraulic fluid according to ISO 4406 |
Class 18/16/13 (for particle size ≤ 4/6/14 μm) | ||
electrical
|
Operating voltage |
UB |
24 VDC +40 % –5 % | ||
|
Operating range (short-time operation) |
Upper limit value |
UB(t)max |
V |
35 |
|
Lower limit value |
UB(t)min |
V |
21 | |
|
Current consumption (in static control operation) |
Rated current |
Inom |
A |
0.6 |
|
Maximum current |
Imax |
A |
1.25 | |
|
Inputs |
Actual pressure value input X1; |
U or I |
parameterizable: 0 ... 20 mA; 4 ... 20 mA; 0 ... 10 V; 0 … 5 V; 0.5 … 5 V; 0.1 ... 10 V; 1 ... 10 V | |
|
Analog current inputs, load |
RB |
100 Ω | ||
|
Analog voltage inputs |
RE |
≥ 100 kΩ | ||
|
Digital inputs |
Logic 0 |
≤ 8 V | ||
|
Logic 1 |
≥ 14 V | |||
|
Outputs |
pactual / UOUT1 |
UO 1) |
± 10 V | |
|
Imax 1) |
2 mA | |||
|
αactual / UOUT2 |
UO 1) |
± 10 V | ||
|
Imax 1) |
2 mA | |||
|
Digital outputs |
Logic 0 |
Ua < 1 V | ||
|
Logic 1 |
Ua ≥ UB – 5 V; 10 mA (short-circuit-proof) | |||
|
Ambient temperature range at the pump |
ϑ |
°C |
0 … +50 | |
|
Storage temperature range (pump + electronics) |
ϑ |
°C |
0 … +70 | |
|
Type of protection according to EN 60529 |
Pump incl. pilot valve |
IP65 with mounted and locked plug-in connectors | ||
| 1) | The outputs are parameterizable, for the condition as supplied, see electrical connection |
mechanisch und hydraulisch
|
Weight without filling quantity |
m |
kg |
2.25 |
|
Hydraulic fluid |
Mineral oil (HL, HLP) according to DIN 51524; HFC fluids only in connection with SYHDFE control system and C spool design C (feature 2 of ordering code) | ||
|
Hydraulic fluid temperature range |
ϑ |
°C |
-20 … +70 |
|
Maximum admissible degree of contamination of the hydraulic fluid according to ISO 4406 |
Class 18/16/13 (for particle size ≤ 4/6/14 μm) | ||
elektrisch
|
Operating voltage |
UB |
24 VDC +40 % –5 % | ||
|
Operating range (short-time operation) |
Upper limit value |
UB(t)max |
V |
35 |
|
Lower limit value |
UB(t)min |
V |
21 | |
|
Current consumption (in static control operation) |
Rated current |
Inom |
A |
0.6 |
|
Maximum current |
Imax |
A |
1.25 | |
|
Inputs |
Actual pressure value input X1; |
U or I |
parameterizable: 0 ... 20 mA; 4 ... 20 mA; 0 ... 10 V; 0 … 5 V; 0.5 … 5 V; 0.1 ... 10 V; 1 ... 10 V | |
|
Analog current inputs, load |
RB |
100 Ω | ||
|
Analog voltage inputs |
RE |
≥ 100 kΩ | ||
|
Digital inputs |
Logic 0 |
≤ 8 V | ||
|
Logic 1 |
≥ 14 V | |||
|
Outputs |
nactual / UOUT1 |
UO 1) |
± 10 V | |
|
Imax 1) |
2 mA | |||
|
αactual / UOUT2 |
UO 1) |
± 10 V | ||
|
Imax 1) |
2 mA | |||
|
Digital outputs |
Logic 0 |
Ua < 1 V | ||
|
Logic 1 |
Ua ≥ UB – 5 V; 10 mA (short-circuit-proof) | |||
|
Ambient temperature range at the pump |
ϑ |
°C |
0 … +50 | |
|
Storage temperature range (pump + electronics) |
ϑ |
°C |
0 … +70 | |
|
Type of protection according to EN 60529 |
Pump incl. pilot valve |
IP65 with mounted and locked plug-in connectors | ||
| 1) | The outputs are parameterizable, for the condition as supplied, see electrical connection |
elektrisch
|
Operating voltage |
UB |
24 VDC +40 % –5 % | ||
|
Operating range (short-time operation) |
Upper limit value |
UB(t)max |
V |
35 |
|
Lower limit value |
UB(t)min |
V |
21 | |
|
Current consumption (in static control operation) |
Rated current |
Inom |
A |
0.6 |
|
Maximum current |
Imax |
A |
1.25 | |
|
Inputs |
Actual pressure value input X1; |
U or I |
parameterizable: 0 ... 20 mA; 4 ... 20 mA; 0 ... 10 V; 0 … 5 V; 0.5 … 5 V; 0.1 ... 10 V; 1 ... 10 V | |
|
Analog current inputs, load |
RB |
100 Ω | ||
|
Analog voltage inputs |
RE |
≥ 100 kΩ | ||
|
Digital inputs |
Logic 0 |
≤ 8 V | ||
|
Logic 1 |
≥ 14 V | |||
|
Outputs |
pactual / UOUT1 |
UO |
± 10 V | |
|
Imax |
2 mA | |||
|
αactual / UOUT2 |
UO |
± 10 V | ||
|
Imax |
2 mA | |||
|
Digital outputs |
Logic 0 |
Ua < 1 V | ||
|
Logic 1 |
Ua ≥ UB – 5 V; 10 mA (short-circuit-proof) | |||
|
Ambient temperature range at the pump |
ϑ |
°C |
0 … +50 | |
|
Storage temperature range (pump + electronics) |
ϑ |
°C |
0 … +70 | |
|
Type of protection according to EN 60529 |
Pump incl. pilot valve |
IP65 with mounted and locked plug-in connectors | ||
| 1) | The outputs are parameterizable, for the condition as supplied, see electrical connection |
mechanisch und hydraulisch
|
Mass |
Pump without through-drive incl. pilot valve |
m |
kg |
2.25 |
|
Hydraulic fluid |
Mineral oil (HL, HLP) according to DIN 51524; HFC fluids only in connection with SYHDFE control system and C spool design C (feature 2 of ordering code) | |||
|
Hydraulic fluid temperature range |
ϑ |
°C |
-20 … +70 | |
|
Maximum admissible degree of contamination of the hydraulic fluid according to ISO 4406 |
Class 18/16/13 (for particle size ≤ 4/6/14 μm) | |||
elektrisch
|
Operating voltage |
UB |
24 VDC +40 % –5 % | ||
|
Operating range (short-time operation) |
Upper limit value |
UB(t)max |
V |
35 |
|
Lower limit value |
UB(t)min |
V |
21 | |
|
Current consumption (in static control operation) |
Rated current |
Inom |
A |
0.6 |
|
Maximum current |
Imax |
A |
1.25 | |
|
Inputs |
Actual pressure value input X1; |
U or I |
parameterizable: 0 ... 20 mA; 4 ... 20 mA; 0 ... 10 V; 0 … 5 V; 0.5 … 5 V; 0.1 ... 10 V; 1 ... 10 V | |
|
Analog current inputs, load |
RB |
100 Ω | ||
|
Analog voltage inputs |
RE |
≥ 100 kΩ | ||
|
Digital inputs |
Logic 0 |
≤ 8 V | ||
|
Logic 1 |
≥ 14 V | |||
|
Outputs |
pactual / UOUT1 |
UO |
± 10 V | |
|
Imax |
2 mA | |||
|
αactual / UOUT2 |
UO |
± 10 V | ||
|
Imax |
2 mA | |||
|
Digital outputs |
Logic 0 |
Ua < 1 V | ||
|
Logic 1 |
Ua ≥ UB – 5 V; 10 mA (short-circuit-proof) | |||
|
Ambient temperature range at the pump |
ϑ |
°C |
0 … +50 | |
|
Storage temperature range (pump + electronics) |
ϑ |
°C |
0 … +70 | |
|
Type of protection according to EN 60529 |
Pump incl. pilot valve |
IP65 with mounted and locked plug-in connectors | ||
| 1) | The outputs are parameterizable, for the condition as supplied, see electrical connection |
Notice:
For information on the environment simulation testing for the areas of EMC (electro-magnetic compatibility), climate and mechanical load, see data sheet 30030-U.
For applications outside these parameters, please consult us!
With integrated digital electronics
Allocation of connector or mating connector and cable set
X2: Connection of pressure transducer HM 16 and serial interface RS232 (mating connector M12)
|
Pin |
Signal HM 16 |
Pin |
Signal RS232 |
|
1 |
OUT, +UB |
2 |
RxD |
|
3 |
Reference L0 |
||
|
4 |
IN, analog, 0.5 to 5 V DC |
5 |
TxD |
X3: Connection CAN bus and digital input 2 (DI2) (connector M12)
|
Pin |
Signal input |
Pin |
Signal CAN |
|
1 |
n.c. |
3 |
CAN GND |
|
2 |
IN, digital IN2 (DI2) |
4 |
CAN-HIGH |
|
5 |
CAN-LOW |
Dimensions in mm
|
1 |
Valve housing |
|
2 |
Proportional solenoid with position transducer |
|
3b |
Mating connector for connector X1 (separate order see Accessories) |
|
5 |
Identical seal rings for ports P, A, and T |
|
6 |
Solenoid rotated by 90° (installation orientation "2") |
|
7 |
Connection swivel angle position sensor (rotary angle sensor VT-SWA-1-1X) |
|
8 |
Name plate |
|
9 |
Integrated electronics |
|
10 |
Mating connector X2 for connection of a pressure transducer HM 16 |
|
11 |
Mating connector X3 for connection of the CAN bus |
|
12 |
Space required for plug-in connection (HM 16) |
|
13 |
Dimension for version VT-DFPC (connection for HM 16 or CAN bus) |
|
14 |
machined valve contact surface |
|
15 |
Space required for CAN connection (plug-in connection on the customer side) |
Valve mounting screws for all types:
4 hexagon socket head cap screws
ISO4762-M6X40-10.9-flZn-240h-L,
friction coefficient μtotal = 0.09 to 0.14 according to VDA 235-101,
Tightening torque MA = 7 Nm,