***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Bosch Rexroth directly.***
The Bosch Rexroth LC50DR80E7X/V (R900700176) is a high-performance way cartridge valve designed for pressure functions, particularly in the area of pressure reduction. This pilot-operated valve is available in both seat and spool designs, ensuring versatility and compatibility with a variety of hydraulic systems. Engineered to fit standardized receiving holes according to DIN ISO specifications, the LC50DR80E7X/V is easily integrated into existing setups and secured with a control cover. The model features an integrated pilot control valve which can be manually or electrically adjusted for proportional pressure changes. This control valve is either built into the control cover or mounted on it, adhering to mounting dimensions set out by DIN standards. The flexibility of this system allows for the implementation of different pressure functions by combining various cartridge valves with their respective control covers. Specifically tailored for pressure reducing functions, this model operates with a rest position that remains open. The spool valve design is notable for not having an area difference at port B, meaning there are no effective areas that could affect performance at this port. It utilizes cover types from the LFA series for its pilot control valve—a feature that ensures consistent and reliable operation. The operation principle involves directing the effective pressure at port A through a pilot oil supply orifice to the spring side of the spool. Under normal conditions and within set pressures, the spool remains open due to spring force, allowing free flow from port B to port A. Once the system reaches the predetermined pressure level, the spool closes, thus reducing pressure at port A as per its characteristic curve. This Bosch Rexroth cartridge valve excels in applications requiring precise control over hydraulic pressures and flows up to its maximum specified flow rate per minute. Its robust design ensures longevity and reliability in demanding operational conditions.

General

2-way cartridge valves for pressure functions are pilot-operated valves in seat or spool design. The power section designed as cartridge valve (1) is installed into a receiving hole standardized according to DIN ISO 7368 and closed with a control cover (2).

The pilot control valve (4) for manual or electrically proportional pressure adjustment is integrated into the control cover (2) or is installed on the control cover (2) as pilot valve with mounting dimensions according to DIN 24 340.

By combination of cartridge valves with the control covers, different pressure functions can be realized. .

technical illustration-R900700176-

Pressure reducing function

Rest position open

The cartridge valve for the pressure reducing function is designed as spool valve without area difference (no effective areas at port B).

As pilot control valve, identical cover types as for the pressure relief function are applied (type LFA..DB...).

The effective pressure at port A is directed via the pilot oil supply orifice to the spring side of the spool. Under the performance limit and the pressure set at the pilot control valve, the spool is pressure-compensated and retained in open position by the spring force to enable free flow from port B to port A.

On reaching the set pressure, the spool is closed and the pressure at port A is reduced according to the pressure-flow characteristics.

Type

01

Cartridge valve

LC

Size

02

NG 16

16

NG 25

25

NG 32

32

NG 40

40

NG 50

50

NG 63

63

Version

03

Pressure relief function

DR

Cracking pressure

04

Cracking pressure 0 bar (without spring)

00

Cracking pressure approx. 2 bar

20

Cracking pressure approx. 3 bar

1)

30

Cracking pressure approx. 4 bar

40

Cracking pressure approx. 5 bar (NG16, 25 and 32 only)

50

Cracking pressure approx. 8 bar

2)

80

Damping

05

Piston without precision grooves

E

Component series

06

Component series 70 ... 79 (70 ... 79: unchanged installation and connection dimensions)

7X

Seal material

07

NBR seals

no code

FKM seals

V

01

02

03

04

05

06

07

LC

DR

E

7X

/

Additional preferred types and standard units are specified in the EPS (standard price list).

Hydraulic fluid

Classification

Suitable sealing materials

Standards

Mineral oil

HL, HLP

FKM, NBR

DIN 51524

Bio-degradable

Insoluble in water

HEES (synthetic esters)

FKM

VDMA 24568

HETG (rape seed oil)

FKM, NBR

Soluble in water

HEPG (polyglycols)

FKM

VDMA 24568

Other hydraulic fluids on request

hydraulic

Size

16 25 32 40 50 63

Maximum operating pressure

Port A

bar

315

Port B

bar

315

Maximum flow

LC..DR20.../..

l/min

100 200 300 750 1000 1600

LC..DR40.../..

l/min

150 300 450 1000 1300 2000

Hydraulic fluid

Mineral oil (HL, HLP) according to DIN 51524; fast biodegradable hydraulic fluids according to VDMA 24568 ; HETG (rape seed oil); HEPG (polyglycols); HEES (synthetic esters), other hydraulic fluids on request

Hydraulic fluid temperature range

NBR seals

°C

-30 … +80

FKM seals

°C

-20 … +80

Viscosity range

mm²/s

2.8 … 380

Maximum admissible degree of contamination of the hydraulic fluid 1)

Class 20/18/15 according to ISO 4406 (c)
1) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.

For applications outside these parameters, please consult us!

(measured with HLP46, ϑOil = 40 ±5 °C)

LC 16 DR…

technical illustration-R900700176-

LC 16 DR…

technical illustration-R900700176-

LC 16 DR…

technical illustration-R900700176-

LC 16 DR…

technical illustration-R900700176-

(measured with HLP46, ϑOil = 40 ±5 °C)

LC 25 DR…

technical illustration-R900700176-

LC 25 DR…

technical illustration-R900700176-

LC 25 DR…

technical illustration-R900700176-

LC 25 DR…

technical illustration-R900700176-

(measured with HLP46, ϑOil = 40 ±5 °C)

LC 32 DR…

technical illustration-R900700176-

LC 32 DR…

technical illustration-R900700176-

LC 32 DR…

technical illustration-R900700176-

LC 32 DR…

technical illustration-R900700176-

(measured with HLP46, ϑOil = 40 ±5 °C)

LC 40 DR…

technical illustration-R900700176-

LC 40 DR…

technical illustration-R900700176-

LC 40 DR…

technical illustration-R900700176-

LC 40 DR…

technical illustration-R900700176-

(measured with HLP46, ϑOil = 40 ±5 °C)

LC 50 DR…

technical illustration-R900700176-

LC 50 DR…

technical illustration-R900700176-

LC 50 DR…

technical illustration-R900700176-

LC 50 DR…

technical illustration-R900700176-

(measured with HLP46, ϑOil = 40 ±5 °C)

LC 63 DR…

technical illustration-R900700176-

LC 63 DR…

technical illustration-R900700176-

LC 63 DR…

technical illustration-R900700176-

LC 63 DR…

technical illustration-R900700176-
technical illustration-R900700176-

Version "E"

Version “D”

Area ratio
A1 : A2 = 2 : 1
Version "…A.E…"

Area ratio
A1 : A2 = 14.3 : 1
Version "…B.E…"

Area ratio
A1 : A2 = 2 : 1
Version "…A.D…"

Area ratio
A1 : A2 = 14.3 : 1
Version "…B.D…"

technical illustration-R900700176-

Installation bore and connection dimensions according to ISO 7368

Dimensions in mm

technical illustration-R900700176-

1

Depth of fit

2

Control dimension

3

If a different diameter is used for port B than ØD3 or (ØD3*), the distance from the cover support surface to the bore center must be calculated.

4

Port B may be positioned around the central axis of port A. However, it must be observed that the mounting bores and the control bores are not damaged.

7

At Ø ≤45 mm → Fitting H8 admissible

NG

ØD1

ØD2

ØD3/(ØD3*)

ØD4

ØD5

ØD6 1)

ØD7

H1/(H1*)

H2

H3

H4

H5

H6

H7

H8

H9

L1

L2

L3

L4

L5

W

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

16 32 H7
-
16 16
25
25 H7
-
M8 8 4 H13
-
35
29.5
56 43 20 11 2 20 2 0.5 65
80
46 23 25 10.5 0.05
25 45 H7
-
25 25
32
34 H7
-
M12 6 6 H13
-
44
40.5
72 58 25 12 2.5 30 2.5 1 85
-
58 29 33 16 0.05
32 60 H7
-
32 32
40
45 H7
-
M16 8 6 H13
-
52
48
85 70 35 13 2.5 30 2.5 1.5 102
-
70 35 41 17 0.1
40 75 H7
-
40 40
50
55 H7
-
M20 10 6 H13
-
64
59
105 87 45 15 3 30 3 2.5 125
-
85 42.5 50 23 0.1
50 90 H7
-
50 50
63
68 H7
-
M20 10 8 H13
-
72
65.5
122 100 45 17 3 35 4 2.5 140
-
100 50 58 30 0.1
63 120 H7
-
63 63
80
90 H7
-
M30 12 8 H13
-
95
86.5
155 130 65 20 4 40 4 3 180
-
125 62.5 75 38 0.2
1) Maximum dimension