BOSCH REXROTH
R900784572
- BOSCH REXROTH
- Material:R900784572
- Model:DR10DP2-4X/210YM/12
Quantity in stock: 0
The Bosch Rexroth DR10DP2-4X/210YM/12 (R900784572) is a direct operated pressure reducing valve designed for subplate mounting and conforms to DIN Form D and ISO porting patterns. This model is specifically crafted to manage system pressure by limiting the secondary circuit's pressure. The secondary pressure is adjustable, allowing for precise control based on application needs. In its initial position, the valve permits unobstructed flow from channel B to channel A, with the pressure in channel A regulated by a control line that influences a piston against a compression spring. When the set value of the compression spring is exceeded, the control spool activates to maintain a constant pressure level in channel A. The valve features internal signal and pilot oil supply through the control line from channel A. An increase in pressure due to external forces causes further displacement of the control spool against the spring, connecting channel A to tank via channel TY, ensuring only slight pressure increases. Leakage oil from the spring chamber is discharged externally through channel TY. Additionally, there's an option for installing a check valve for free flow back from channel A to B. Monitoring and controlling secondary pressure is facilitated by a dedicated pressure gauge connection. Available adjustment types for this model include rotary knob, threaded pin with hexagon and protective cap, lockable rotary knob with scale, or rotary knob with scale. The DR10DP2-4X/210YM/12 supports various pressure ratings and includes an optional check valve. It has been engineered to handle maximum operating pressures up to certain bar levels and maximum flow rates expressed in liters per minute (l/min), ensuring it meets diverse hydraulic system requirements while maintaining efficiency and reliability.
The valve type DR 10 DP is a direct operated pressure reducing valve in 3-way version, i. e. with pressure limitation of the secondary circuit.
It is used to limit a system pressure.
The secondary pressure is set via the adjustment type (1).
The valve is open in initial position. Hydraulic fluid can flow from channel B to channel A without restrictions. The pressure in channel A is simultaneously applied via the control line (4) at the piston area opposite the compression spring (3). If the pressure in channel A exceeds the value set at the compression spring (3), the control spool (2) moves to control position and keeps the set pressure in channel A at a constant level.
Signal and pilot oil are supplied internally via the control line (4) from channel A.
If the pressure in channel A increases further due to an external force effect at the actuator, it pushes the control spool (2) even further against the compression spring (3).
In this way, channel A is connected to channel T(Y) via the control edge (5) at the control spool (2). So much hydraulic fluid is discharged into the tank that the pressure can only increase slightly.
The leakage oil discharge from the spring chamber (6) is always effected externally via channel T(Y).
For the free flow back from channel A to channel B, a check valve (7) can optionally be installed.
A pressure gauge connection (8) allows for the control of the secondary pressure.
Type DR 10 DP1-4X/.Y…
|
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
||
|
DR 10 DP |
– |
4X |
/ |
Y |
* |
|
01 |
Pressure reducing valve, direct operated, size 10 |
DR 10 DP |
|
Adjustment type |
||
|
02 |
Rotary knob |
1 |
|
Grub screw with hexagon and protective cap |
2 |
|
|
Lockable rotary knob with scale |
31) |
|
|
Rotary knob with scale |
7 |
|
|
03 |
Component series 40 … 49 (40 … 49: unchanged installation and mounting dimensions) |
4X |
|
04 |
Maximum secondary pressure 25 bar |
25 |
|
Maximum secondary pressure 75 bar |
75 |
|
|
Maximum secondary pressure 150 bar |
150 |
|
|
Maximum secondary pressure 210 bar |
210 |
|
|
05 |
Internal pilot oil supply, external leakage oil discharge |
Y |
|
06 |
With check valve |
no code |
|
Without check valve |
M |
|
|
Seal material |
||
|
07 |
NBR seals |
no code |
|
FKM seals (other seals on request) Attention! Observe compatibility of seals with the hydraulic fluid used! |
V |
|
|
08 |
Further details in the plain text |
* |
1) H-key with material no. R900008158 is included in the scope of delivery.
Preferred types and standard units are contained in the EPS (standard price list).
general
|
Size |
10 | ||
|
Installation position |
any | ||
|
Ambient temperature range |
NBR seals |
°C |
-30 … +50 |
|
FKM seals |
°C |
-20 … +50 | |
|
Weight |
kg |
3 | |
hydraulic
|
Size |
10 | ||
|
Maximum operating pressure |
Port B |
bar |
315 |
|
Maximum secondary pressure |
Port A |
bar |
25 75 150 210 |
|
Maximum counter pressure |
Port T (Y) |
bar |
160 |
|
Maximum flow |
l/min |
80 | |
|
Hydraulic fluid |
see table | ||
|
Hydraulic fluid temperature range |
NBR seals |
°C |
-30 … +80 |
|
FKM seal |
°C |
-20 … +80 | |
|
Viscosity range |
mm²/s |
10 … 800 | |
|
Maximum admissible degree of contamination of the hydraulic fluid 1) |
Class 20/18/15 according to ISO 4406 (c) | ||
| 1) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
|
Hydraulic fluid |
Classification |
Suitable sealing materials |
Standards |
|
|
Mineral oils and related hydrocarbons |
HL, HLP, HLPD |
NBR, FKM |
DIN 51524 |
|
|
Environmentally compatible |
Insoluble in water |
HETG |
NBR, FKM |
ISO 15380 |
|
HEES |
FKM |
|||
|
Soluble in water |
HEPG |
FKM |
ISO 15380 |
|
|
Containing water |
Water-free |
HFDU, HFDR |
FKM |
ISO 12922 |
|
Containing water |
HFC (Fuchs Hydrotherm 46M, Petrofer Ultra Safe 620) |
NBR |
ISO 12922 |
|
|
Important information on hydraulic fluids! For further information and data on the use of other hydraulic fluids, please refer to data sheet 90220 or contact us! There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.)!Flame-resistant – containing water: Maximum operating pressure 210 bar Maximum hydraulic fluid temperature 60 °C Expected life cycle as compared to HLP hydraulic oil 30 % to 100 % |
||||
For applications outside these parameters, please consult us!
(measured with HLP46, ϑOil = 40 ±5 °C)
pA-qV characteristic curves
Δp-qV characteristic curves
Notice!
The curve development is maintained if the pressure is set lower according to the pressure rating.
The characteristic curves apply to the pressure at the valve output p = 0 bar across the entire flow range.
Version "M"
Without check valve
Version "no code"
With check valve
Dimensions in mm
|
1 |
Name plate |
|
2 |
Adjustment type "1" |
|
3 |
Adjustment type "2" |
|
4 |
Adjustment type "3" |
|
5 |
Adjustment type "7" |
|
6 |
Space required to remove the key |
|
7 |
Valve mounting bores |
|
8 |
Lock nut SW24 |
|
9 |
Hexagon SW10 |
|
10 |
Identical seal rings for ports A, B, P, T (Y) |
|
11 |
Pressure gauge connection G1/4; 12 mm deep; internal hexagon SW6 |
|
12 |
Locking pin |
|
13 |
Porting pattern according to DIN 24340 form D and ISO 5781-06-07-0-00 |
Subplates (separate order)
G 460/01 (G3/8)
G 461/01 (G1/2)
Valve mounting screws (separate order)
4 metric hexagon socket head cap screws
ISO 4762 - M10 x 60 - 10.9-flZn-240h-L
with friction coefficient μtotal = 0.09 to 0.14,
tightening torque MA = 60 Nm ± 10%,
material no. R912000116