BOSCH REXROTH
R901064382
- BOSCH REXROTH
- Material:R901064382
- Model:KBPSL8BA/HCG24K40V
Quantity in stock: 0
The Bosch Rexroth KBPSL8BA/HCG24K40V (R901064382) is a high-performance proportional pressure relief valve designed for precise pressure control in hydraulic systems. This direct-operated, screw-in cartridge valve features a decreasing characteristic curve and is equipped with an electroproportional actuation mechanism. It functions to limit system pressure by utilizing a poppet-type spool within its robust design. The valve's maximum operating pressure reaches up to 315 bar (4568 psi), with the ability to handle a maximum flow of 40 liters per minute (10.6 gpm). The KBPSL8BA/HCG24K40V is engineered for seamless integration into SUN TA cavities and utilizes FKM sealing material for reliable performance under various conditions. Its electroproportional control allows for stepless adjustments of system pressure, ensuring precise regulation and responsive behavior. The unit comes with an integrated coil and a Deutsch DTP electrical connector, ensuring easy installation and maintenance. This model is particularly suitable for mobile and industrial applications where accurate pressure limitation is critical. It features external fine balancing capabilities for the command value-pressure characteristic curve via the control electronics, allowing users to achieve optimal performance tailored to their specific requirements. In case of power failure or when command value reaches zero, the valve automatically sets to the configured maximum pressure as a safety measure. With its direct-acting pilot control and normally closed normal position, the Bosch Rexroth KBPSL8BA/HCG24K40V offers reliable operation in a compact form factor. Hydraulic fluids compatible with this valve include HL, HLP, HEES, and HEPG types, providing versatility across various hydraulic systems. The product's size and component series A designation ensure it meets industry standards for ease of replacement or system upgrades.
Proportional pressure relief valve, direct operated, decreasing characteristic curve
Unpacked Weight: 0.44 kg
Valves of type KBPS.8B are direct operated proportional pressure relief valves (pilot control valves) in seat design and are used to limit a system pressure. At command value 0 or in the event of a power failure, the maximum pressure is set. Operation by means of a proportional solenoid with central thread and detachable coil. The solenoid's interior is connected to the main port and filled with hydraulic fluid. Dependent on the electric command value, these valves can be used to steplessly set the system pressure to be limited.
| Screw-in cartridge valve |
| Maximum operating pressure 420 bar (6000 psi) |
| Maximum flow 2 l/min (0,5 gpm) |
| Cavity SUN T-8A |
| Max. pressure | 420 |
| Coil | GP37 |
| Product family classification | Proportional pressure relief valve, direct operated, decreasing characteristic curve |
| Productgroup ID | 9,10,11,12,13,14 |
| Product family type | KBPS |
| Ports number | 2 |
| Type of actuation | Electro-proportional |
| Sealing material | FKM |
| Cavity | Sun T-8A |
| Product type | KBPS |
| Electrical connector | Deutsch DT04-2P |
| Max. flow | 2 |
| Type of connection | Screw-in cartridge valve |
| Normal position | Normally closed |
| Nominal flow | 2 |
| Direct - Pilot | Direct acting |
| Product family | Relief |
| Supply voltage | 24 V DC |
| Coil integrated | Integrated coil |
| Spool Poppet | Poppet type |
| Weight | 0.44 |
| Hydraulic fluid | HL,HLP,HEES,HEPG |
|
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
10 |
11 |
12 |
|
|
KBPS |
8 |
B |
A |
/ |
H |
C |
V |
* |
|
01 |
Proportional pressure relief valve, direct operated (pilot control valve) |
KBPS |
|
Pressure rating |
||
|
02 |
Up to 30 bar |
B |
|
Up to 50 bar |
C |
|
|
Up to 100 bar |
F |
|
|
Up to 150 bar |
H |
|
|
Up to 210 bar |
L |
|
|
Up to 250 bar |
N |
|
|
Up to 315 bar |
P |
|
|
Up to 350 bar |
R |
|
|
Up to 420 bar |
T |
|
|
03 |
Component size |
8 |
|
04 |
Maximum pressure at command value = 0 |
B |
|
05 |
Component series |
A |
|
06 |
High Performance and mounting cavity R/T-8A (see mounting cavity) |
H |
|
07 |
Proportional solenoid, wet-pin |
C |
|
Power supply |
||
|
08 |
Control electronics 12 V DC |
G12 |
|
Control electronics 24 V DC |
G24 |
|
|
Electrical connection |
||
|
09 |
Without mating connector, with connector according to DIN EN 175301-803, separate order |
K4 |
|
Without mating connector, with connector DT 04 - 2PA (Deutsch plug) |
K40 |
|
|
Without mating connector, with connector AMP Junior-Timer |
C4 |
|
|
Seal material |
||
|
10 |
FKM seals |
V |
|
11 |
Standard version |
no code |
|
800 mA coil |
-8 |
|
|
12 |
Further details in the plain text |
* |
For applications outside these parameters, please consult us!
general
|
Type |
KBPS.8B | |
|
Size |
8 | |
|
Component series |
A | |
|
Weight |
kg |
0.45 |
|
Installation position |
any - if it is ensured that no air can collect upstream of the valve. Otherwise, we recommend suspended installation of the valve. | |
|
Ambient temperature range |
°C |
-20 … +120 |
electrical
|
Type |
KBPS.8B | |
|
Duty cycle |
% |
100 |
hydraulic
|
Type |
KBPS.8B | ||
|
Maximum flow |
l/min |
2 | |
|
Hydraulic fluid temperature range |
°C |
-20 … +80 | |
|
Viscosity range |
mm²/s |
15 … 380 | |
|
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 1) |
Class 20/18/15 according to ISO 4406 (c) | ||
|
Hysteresis 2) |
% |
< 4 | |
|
Range of inversion 2) |
% |
< 0.5 | |
|
Response sensitivity 2) |
% |
< 0.5 | |
|
Manufacturing tolerance of the command value pressure characteristic curve, related to 0.8 l/min; pressure increasing |
at command value 100 % 2) |
% |
< 2 |
|
Step response |
0% → 100% 3) |
ms |
70 |
|
100% → 0% 3) |
ms |
70 | |
| 1) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
| 2) | Of the maximum set pressure |
| 3) | depending on the system |