You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

BOSCH REXROTH
R901112187

  • BOSCH REXROTH
  • Material:R901112187
  • Model:4WMRZ6Y6X/YBW/ZVSO129

Due to extremely high demand, please call 877-366-7226 for availability

***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Bosch Rexroth directly.***
The Bosch Rexroth 4WMRZ6Y6X/YBW/ZVSO129 (R901112187) is a meticulously engineered directional spool valve designed for precise control over the start, stop, and direction of fluid flow within a hydraulic system. This particular model falls under the Type WM series of valves, which are recognized for their robust construction and manual actuation via a roller plunger. The valve's housing encompasses the control spool and is equipped with one or two return springs to ensure the spool remains in its central or initial position when not actuated. An important feature of this model is its detent mechanism, which allows for fixed spool positions, ensuring consistent and reliable operation during use. This makes it particularly suitable for applications where stable flow control is critical. Additionally, the 4WMRZ6Y6X/YBW/ZVSO129 valve can accommodate throttle inserts in channel P to manage any flows that might exceed the valve's performance limit during switching processes. The valve's design adheres to industry standards with porting patterns that comply with DIN form A without locating holes and ISO with locating holes, ensuring compatibility with a wide range of systems. The type of actuation provided by this model is via a roller plunger, while also supporting inductive position switches and proximity sensors for contactless detection. With a size component series X, this directional valve can withstand a maximum operating pressure of up to bar and facilitate a maximum flow rate of l/min. The 4WMRZ6Y6X/YBW/ZVSO129 is designed as a , , or way version, providing flexibility in application depending on specific system requirements. Its precise engineering and versatile design make it an essential component for hydraulic systems requiring manual control over fluid dynamics.

Type WM.. valves are mechanical, manually actuated directional spool valves. They control the start, stop and direction of a flow. Directional valves basically consist of housing (1), one type of actuation (2) (roller plunger), control spool (3) and one or two return springs (4). In de-energized state, the return springs (4) maintain the control spool (3) in central or starting position - if the rotary knob is actuated with a detent. The control spool (3) is moved to the desired spool position by means of the type of actuation (2).

Detent

Directional valves with rotary knob are generally designed with detent. Directional valves with hand lever are optionally available as 2 or 3 position valves with detent. Directional valves with roller plunger are generally designed without detent. If types of actuation with detent are used, each spool position can be fixed, depending on the valve type.

Throttle insert

The use of a throttle insert is required when due to prevailing operating conditions, flows can occur during the switching processes, which exceed the performance limit of the valve. It is inserted in channel P of the directional valve.

Type 4WM. 6 ..5X/..B..

Type 4WMRZ 6 D6X/…

technical illustration-R901112187-4/3-, 4/2- or 3/2-way version Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Type of actuation: Roller plunger Inductive position switch and proximity sensors (contactless)
technical illustration-R901112187-4/3-, 4/2- or 3/2-way version Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Type of actuation: Roller plunger Inductive position switch and proximity sensors (contactless)

01

02

03

04

05

06

07

08

09

10

11

12

13

WMRZ

6

6X

/

no code

/

Z

*

01

3 main ports

3

4 main ports

4

Type of actuation

02

Roller plunger (see Dimensions)

WMRZ

03

Size 6

6

04

Symbols e. g. C, E, EA, EB, etc.; for the possible version, see Symbols and Types of actuation

05

Component series 60 … 69 (60 … 69: unchanged installation and connection dimensions)

6X

06

With spring return

ohne Bez.

Corrosion protection

07

Standard corrosion protection

ohne Bez.

Improved corrosion protection

1)

J

Spool position monitoring

2)

08

Without position switch

ohne Bez.

Inductive position switch type QM

Monitored spool position "a"

QMAG24

Monitored spool position "b"

QMBG24

Monitored rest position

QM0G24

09

Without throttle insert

ohne Bez.

Throttle Ø 0.8 mm

B083)

Throttle Ø 1.0 mm

B103)

Throttle Ø 1.2 mm

B123)

Clamping length

10

22 mm

Z

Seal material

11

NBR seals

ohne Bez.

FKM seals

V

Observe compatibility of seals with hydraulic fluid used. (Other seals upon request)

12

Without locating hole

ohne Bez.

With locating hole

/604)

With locating hole and locking pin ISO 8752-3x8-St

/62

13

Further details in the plain text

*

1) The external parts made of metal are galvanized, treated with an anti-corrosion agent or made of stainless steel. This design is also suitable for on-wall applications.
2) Only for valves with 2 spool positions; not for version “J”
3) Use if flow > performance limit of the valve, effective in channel P.
4) Locking pin ISO 8752-3x8-St, material no. R900005694, separate order

Preferred types and standard units are specified in the EPS (standard price list).

hydraulic

Size

6

Maximum operating pressure

Port P

bar

315

Port A

bar

315

Port B

bar

315

Port T 1)

bar

60

Maximum flow

l/min

60

Flow cross-section (spool position 0)

Symbol Q

approx. 6 % of nominal cross-section

Symbol W

approx. 3 % of nominal cross-section

Hydraulic fluid

see table

Hydraulic fluid temperature range

NBR seals

°C

-30 … +80

FKM seals

°C

-20 … +80

Viscosity range

mm²/s

2.8 … 500

Maximum admissible degree of contamination of the hydraulic fluid 2)

Class 20/18/15 according to ISO 4406 (c)
1) With symbols A or B, port T must be used as leakage oil connection if the operating pressure exceeds the admissible tank pressure.
2) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.

Hydraulic fluid

Classification

Suitable sealing materials

Standards

Mineral oils

HL, HLP, HLPD, HVLP, HVLPD

NBR, FKM

DIN 51524

Bio-degradable

Insoluble in water

HETG

NBR, FKM

VDMA 24568

HEES

FKM

Soluble in water

HEPG

FKM

VDMA 24568

Containing water

Water-free

HFDU, HFDR

FKM

ISO 12922

Containing water

HFC (Fuchs Hydrotherm 46M, Petrofer Ultra Safe 620)

NBR, HNBR

ISO 12922

Important information on hydraulic fluids!

For further information and data on the use of other hydraulic fluids, please refer to data sheet 90220 or contact us! There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.)! The flash point of the hydraulic fluid used must be 40 K higher than the maximum solenoid surface temperature.

Flame-resistant – containing water:

Maximum pressure differential per control edge 50 bar. Pressure pre-loading at the tank port >20% of the pressure differential; otherwise, increased cavitation Life cycle compared to operation with mineral oil HL, HLP 50 to 100%

Actuating force/torque

Nenngröße

6

Operating pressure

Anschluss A

bar

315

Port B

bar

315

Port P

bar

315

Actuating force at the roller plunger

without tank pressure

N

30

with tank pressure

N

160

Calculation formula for the actuating force at the roller plunger (FR) at a tank pressure:

FR = Fwithout tank pressure + pT x 1.4 N/bar

Inductive position switch type QM: electrical connection

The electric connection is realized via a 4-pole mating connector (separate order) with connection thread M12 x 1.

electrical

Connection voltage (DC voltage)

V

24

Voltage tolerance (connection voltage)

+30 %/-15 %

Admissible residual ripple

%

≤ 10

Max. load capacity

mA

400

Switching outputs

technical illustration-R901112187-4/3-, 4/2- or 3/2-way version Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Type of actuation: Roller plunger Inductive position switch and proximity sensors (contactless)
PNP transistor outputs, load between switching outputs and GND

Pinout

technical illustration-R901112187-4/3-, 4/2- or 3/2-way version Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Type of actuation: Roller plunger Inductive position switch and proximity sensors (contactless)

1

V

24

2, 4

Switching output

mA

400

3

Earthing (GND)

V

0

general

Size

6

Weight (approx.)

kg

1.4

Installation position

any

Ambient temperature range

NBR seals

°C

-20 … +80

FKM seals

°C

-20 … +80

For applications outside these parameters, please consult us!

(measured with HLP46, ϑOil = 40 ±5 °C)

Δp-qV characteristic curves

technical illustration-R901112187-4/3-, 4/2- or 3/2-way version Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Type of actuation: Roller plunger Inductive position switch and proximity sensors (contactless)

7

Symbol “R” in spool position "b" (A → B)

8

Symbols “G” and “T” in central position (P → T)

Symbols

Direction of flow

P-A

P-B

A-T

B-T

A

3

3

B

3

3

C

1

1

3

1

D

5

5

3

3

E

3

3

1

1

F

1

3

1

1

G

6

6

9

9

H

2

4

2

2

J

1

1

2

1

L

3

3

4

9

M

2

4

3

3

P

3

1

1

1

Q

1

1

2

1

R

5

5

4

T

10

10

9

9

U

3

3

9

4

V

1

2

1

1

W

1

1

2

2

Y

5

5

3

3

Performance limits

(measured with HLP46, ϑOil = 40 ±5 °C)

 

Notice!

The specified switching power limits are valid for use with two directions of flow (e. g. from P to A and simultaneous return flow from B to T).

Due to the flow forces acting within the valves, the admissible switching power limits may be considerably lower with only one direction of flow (e. g. from P to A while port B is blocked)!

In such use cases, please consult us!

technical illustration-R901112187-4/3-, 4/2- or 3/2-way version Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Type of actuation: Roller plunger Inductive position switch and proximity sensors (contactless)
technical illustration-R901112187-4/3-, 4/2- or 3/2-way version Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Type of actuation: Roller plunger Inductive position switch and proximity sensors (contactless)

Characteristic curve

Symbol

1

A,B

2

C,D,Y,E,E1–,H,M,Q,

U,W

3

F,P

4

G

5

J,L

6

R

8

V

7

T

technical illustration-R901112187-4/3-, 4/2- or 3/2-way version Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Type of actuation: Roller plunger Inductive position switch and proximity sensors (contactless)
technical illustration-R901112187-4/3-, 4/2- or 3/2-way version Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Type of actuation: Roller plunger Inductive position switch and proximity sensors (contactless)
1) Example: Symbol E with spool position "a" → ordering code ..EA.. Symbol E with spool position “b" → ordering code ..EB..
3) Symbol E1-: P → A/B pre-opening Caution in conjunction with differential cylinders due to pressure intensification!

Notices!

Representation according to DIN ISO 1219-1.

Hydraulic interim positions are shown by dashes.

Type of actuation

Roller plunger “WMRZ”

1)

technical illustration-R901112187-4/3-, 4/2- or 3/2-way version Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Type of actuation: Roller plunger Inductive position switch and proximity sensors (contactless)
technical illustration-R901112187-4/3-, 4/2- or 3/2-way version Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Type of actuation: Roller plunger Inductive position switch and proximity sensors (contactless)
technical illustration-R901112187-4/3-, 4/2- or 3/2-way version Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Type of actuation: Roller plunger Inductive position switch and proximity sensors (contactless)
technical illustration-R901112187-4/3-, 4/2- or 3/2-way version Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Type of actuation: Roller plunger Inductive position switch and proximity sensors (contactless)

Dimensions in mm

technical illustration-R901112187-4/3-, 4/2- or 3/2-way version Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Type of actuation: Roller plunger Inductive position switch and proximity sensors (contactless)

Dimensions in mm

technical illustration-R901112187-4/3-, 4/2- or 3/2-way version Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Type of actuation: Roller plunger Inductive position switch and proximity sensors (contactless)

1

Name plate

2

Porting pattern according to DIN 24340 form A (without locating hole), ISO 4401-03-02-0-05 and NFPA T3.5.1 R2-2002 D03 (with locating hole for locking pin ISO 8752-3x8-St, material no. R900005694, separate order)

3

Identical seal rings for ports A, B, P, and T

4

Alternative clamping length (): 22 mm

15

Spool position "a" or "b"

16

Spool position "0"

17

Actuation on side B (depending on the piston)

Subplates according to data sheet 45052 (separate order)

(without locating hole)

G 341/01 (G1/4)

G 342/01 (G3/8)

G 502/01 (G1/2)

(with locating hole)

G 341/60 (G1/4)

G 342/60 (G3/8)

G 502/60 (G1/2)

G 341/12 (SAE-6)1)

G 342/12 (SAE-8)1)

G 502/12 (SAE-10)1)

 

Clamping length 22 mm:

4 hexagon socket head cap screws, metric

ISO 4762 - M5 x 30 - 10.9-flZn-240h-L

(friction coefficient μtotal= 0.09 to 0.14);

tightening torque MA = 7 Nm ± 10 %,

material no. R913000316

or

4 hexagon socket head cap screws

ISO 4762 - M5 x 30 - 10.9 (self procurement)

(friction coefficient μtotal = 0.12 to 0.17);

tightening torque MA = 8.1 Nm ± 10 %

4 hexagon socket head cap screws UNC

10-24 UNC x 1 1/4 ″

(friction coefficient μtotal = 0.19 to 0.24);

tightening torque MA = 11 Nm ± 15 %,

(friction coefficient μtotal = 0.12 to 0.17);

tightening torque MA = 8 Nm ± 10 %,

material no. R978802879

Spool position monitoring

Inductive position switch type QM, 4WMM

Dimensions in mm

technical illustration-R901112187-4/3-, 4/2- or 3/2-way version Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Type of actuation: Roller plunger Inductive position switch and proximity sensors (contactless)
1) For dimensions, see valve dimensions

3/2 directional seat valve – with detent

Dimensions in mm

technical illustration-R901112187-4/3-, 4/2- or 3/2-way version Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Type of actuation: Roller plunger Inductive position switch and proximity sensors (contactless)

1

Cover not available for type WMRZ

Notice:

The dimensions are nominal dimensions which are subject to tolerances.