You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

BOSCH REXROTH
R901142355

  • BOSCH REXROTH
  • Material:R901142355
  • Model:VT-MSPA1-10-1X/V0

Due to extremely high demand, please call 877-366-7226 for availability

***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Bosch Rexroth directly.***
The Bosch Rexroth VT-MSPA1-10-1X/V0 (R901142355) is an advanced analog amplifier designed for controlling pressure valves without electrical feedback. This device's modular construction facilitates effortless installation on standard top hat rails commonly found in control cabinets, streamlining the setup process. Equipped with a command value input, the amplifier can be manipulated through a standard command value signal ranging from 0 to 10 V. A zero point potentiometer (Zw) is included for precise zero point offset adjustments. The amplifier also features a ramp generator that limits the incline of the control output, allowing users to set rising and falling command value signal times via trimmers t< and t>, respectively. For achieving a linear command value-pressure characteristic curve, this model incorporates a characteristic curve generator where the trimmer Gw sets the solenoid's rated current at 0.1 A. The clock generator within creates an output stage frequency that corresponds to the command value. The power output stage is another critical component of this device; it produces a PWM signal derived from both the characteristic curve generator and clock frequency, which then powers the solenoid. A current controller monitors this process, ensuring any discrepancies between control output and actual current are corrected. Furthermore, VT-MSPA1-10-1X/V0 boasts fault recognition capabilities that monitor solenoid conductors for issues such as cable breaks, short circuits, and overcurrent in the output stage. In case of an error, an LED indicator will alert by switching off its green 'ready for operation' display. Additional features include differential input for voltage adjustment, separately adjustable ramp times for both up and down signals in the ramp generator, adjustable zero point and sensitivity controls, a dither generator to prevent sticking in proportional valves, LED displays indicating various operating states, and reverse polarity protection to safeguard the operating voltage. This comprehensive array of features makes Bosch Rexroth's VT-MSPA1-10-1X/V0 (R901142355) a robust solution for precise pressure valve control applications.

Analog amplifier for controlling pressure valves without electrical feedback. The modular design allows for simple top hat rail mounting as is usual in control cabinets.

 

Command value input [4]

The module amplifier is controlled by means of a standard command value signal 0 to +10 V. By means of the zero point potentiometer (Zw) [6], a zero point offset can be corrected.

 

Ramp generator [5]

In the ramp generator [5], the control output incline is limited. Using the trimmer "t <" [7], the time for the increasing command value signal is set and using trimmer "t >" [8], the time for the decreasing command value voltage is set.

 

Characteristic curve generator [10]

Using the trimmer "Gw" [9], the rated current of 1.6 A for the solenoid is set. In the characteristic curve generator [10], the command value signal is changed so that a linear command value pressure characteristic curve is created.

 

Clock generator [12]

In the clock generator [12], a frequency for the output stage

adjusted to the command value is generated.

 

Power output stage [11]-[14]

Using the control output coming from the characteristic curve generator [10] and the clock frequency, the power output stage generates a PWM signal that is fed into the solenoid. The solenoid current is recorded and, in the current controller [11], compared with the control output and the difference is compensated.

 

Fault recognition [15]

Monitors the solenoid conductors with reference to cable break and short-circuit as well as over-current of the output stage. If there is an error, the green ready for operation display goes out.

01

02

03

04

05

VT-MSPA1

‒

10

‒

1X

/

V0

/

*

01

Valve amplifier for proportional valves without electrical position feedback, Analog, Modular design

VT-MSPA1

02

For valves: (Z)DRE 6...-1X

10

03

Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions)

1X

04

Version: standard

V0

05

Further details in the plain text

*

General

Component series

1X

Type of electronics

Analog

Design

Modul

Voltage supply

Operating voltage

nominal

U

V

24

Lower limit value

UB(t)min

V

21

Upper limit value

UB(t)max

V

35

Power consumption

max.

Smax

VA

50

Current consumption

max.

Imax

A

1.3

Fuse

Electronic overload protection and SMD fuse (soldered in)

Analog inputs

Command value

Voltage (differential input)

U

V

​0 ... ​10

Voltage (differential input)

Input resistance

R

kΩ

≥ 100

Solenoid outputs

Solenoid current

max.

Imax

A

1.9

Coil resistance at 20°C

R(20)

Ω

5.2

Clock frequency

Factory setting

f

Hz

330 ±10 %

Adjustment options

Solenoid current

I

A

0.1 ... 1.9

Zero point calibration

%

± 25

Ramp time up/down

t

s

0.21 … 5

Measuring sockets

Command value

"w"

U

V

0 ... 10

Actual current value

"I"

U

V

0 ... 1.9 (mV ≙ mA)

Displays

LED display

Green

Ready for operation

Supplementary information

Anschlussart

6 screw terminals

Mounting type

Top hat rail TH 35-7.5 according to EN 60715

Type of protection according to EN 60529

IP 20

Ambient temperature range

ϑ

°C

​0 … ​50

Storage temperature range

ϑ

°C

-25 … ​85

Weight

m

kg

0.15

For applications outside these parameters, please consult us!

Notice:

For information on the environment simulation testing for the areas of EMC (electro-magnetic compatibility), climate and mechanical load, see data sheet 30223-U.

technical illustration-R901142355-Differential input for voltage Ramp generator with separately adjustable ramp times "up/down" Adjustable zero point and sensitivity Characteristic curve generator Clocked power output stage Dither generator LED displays for various operating states Reverse polarity protection for the operating voltage
technical illustration-R901142355-Differential input for voltage Ramp generator with separately adjustable ramp times "up/down" Adjustable zero point and sensitivity Characteristic curve generator Clocked power output stage Dither generator LED displays for various operating states Reverse polarity protection for the operating voltage

Measuring sockets

Command value

Actual current value (mV ≙ mA)

Reference potential

Potentiometer

Gw

Amplitude attenuator

Zw

Zero point

t <

Ramp time "Ramp up"

t >

Ramp time "Ramp down"

technical illustration-R901142355-Differential input for voltage Ramp generator with separately adjustable ramp times "up/down" Adjustable zero point and sensitivity Characteristic curve generator Clocked power output stage Dither generator LED displays for various operating states Reverse polarity protection for the operating voltage

Fuse

Suppressor diode

Power supply unit

Voltage input

Ramp generator

Zero point setting

Ramp time "Ramp up"

Ramp time "Ramp down"

Command value attenuator

Characteristic curve generator

Current controller

Clock generator

Schmitt trigger

Clocked output stage

Fault recognition

Measuring sockets

Dimensions in mm

technical illustration-R901142355-Differential input for voltage Ramp generator with separately adjustable ramp times "up/down" Adjustable zero point and sensitivity Characteristic curve generator Clocked power output stage Dither generator LED displays for various operating states Reverse polarity protection for the operating voltage

Dimensions in mm

technical illustration-R901142355-Differential input for voltage Ramp generator with separately adjustable ramp times "up/down" Adjustable zero point and sensitivity Characteristic curve generator Clocked power output stage Dither generator LED displays for various operating states Reverse polarity protection for the operating voltage

The amplifier module may only be wired when de-energized.

The distance to radios must be sufficient (>> 1 m).

Shield command value lines, do not lay them close to power cables, screen solenoid conductors.

Do not use free-wheeling diodes in the solenoid conductors.

With a strongly fluctuating operating voltage, it may in individual cases be necessary to use an external smoothing capacitor with a capacity of at least 2200 µF.

Recommendation: Capacitor module VT 11110 (see data sheet 30750); sufficient for up to 3 amplifier modules.