***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Bosch Rexroth directly.***
The Bosch Rexroth VT-MSPA1-11-1X/V0/0 (R901142360) is an analog amplifier designed to control pressure valves without electrical feedback. This device features a modular construction that enables easy installation on standard top hat rails commonly used in control cabinets. It accepts a standard command value signal of 0 to 10 V, and with the zero point potentiometer (Zw), users can correct any zero point offset that may occur. The amplifier includes a ramp generator that limits the incline of the control output, allowing for adjustable ramp times for both increasing and decreasing command value signals with trimmers t< and t>, respectively. Additionally, it boasts a characteristic curve generator with a trimmer (Gw) to set the rated current of 1.2 A for the solenoid, ensuring a linear command value-pressure characteristic curve. Furthermore, the VT-MSPA1-11-1X/V0/0 contains a clock generator which produces a frequency adjusted to the command value for the output stage. The power output stage then uses this along with the signal from the characteristic curve generator to create a PWM signal that powers the solenoid. The solenoid current is monitored and compared within the current controller to compensate for any discrepancies. For safety and reliability, this unit features fault recognition capabilities that monitor solenoid conductors for cable breaks, short circuits, and overcurrent conditions in the output stage. If an error is detected, an LED indicator will notify by turning off its green ready-for-operation display. Additional features include differential input for voltage adjustment, dither generation for improved valve performance, LED displays indicating various operating states, and reverse polarity protection for operational voltage security.

Analog amplifier for controlling pressure valves without electrical feedback. The modular design allows for simple top hat rail mounting as is usual in control cabinets.

 

Command value input [4]

The module amplifier is controlled by means of a standard command value signal 0 to +10 V. By means of the zero point potentiometer (Zw) [6], a zero point offset can be corrected.

 

Ramp generator [5]

In the ramp generator [5], the control output incline is limited. Using the trimmer "t <" [7], the time for the increasing command value signal is set and using trimmer "t >" [8], the time for the decreasing command value voltage is set.

 

Characteristic curve generator [10]

Using the trimmer "Gw" [9], the rated current of 1.6 A for the solenoid is set. In the characteristic curve generator [10], the command value signal is changed so that a linear command value pressure characteristic curve is created.

 

Clock generator [12]

In the clock generator [12], a frequency for the output stage

adjusted to the command value is generated.

 

Power output stage [11]-[14]

Using the control output coming from the characteristic curve generator [10] and the clock frequency, the power output stage generates a PWM signal that is fed into the solenoid. The solenoid current is recorded and, in the current controller [11], compared with the control output and the difference is compensated.

 

Fault recognition [15]

Monitors the solenoid conductors with reference to cable break and short-circuit as well as over-current of the output stage. If there is an error, the green ready for operation display goes out.

01

Valve amplifier for proportional valves without electrical position feedback, Analog, Modular design

VT-MSPA1

02

For valves:
3DRE(M) 10...-7X
3DRE(M) 16...-7X
ZDRE 10…-2X
(Z)DBE6...-2X
DRE(M) 10(25,32)-6X

11

03

Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions)

1X

04

Version: standard

V0

05

Further details in the plain text

*

01

02

03

04

05

VT-MSPA1

‒

11

‒

1X

/

V0

/

*

General

Component series

1X

Type of electronics

Analog

Design

Modul

Voltage supply

Operating voltage

nominal

U

V

24

Lower limit value

UB(t)min

V

21

Upper limit value

UB(t)max

V

35

Power consumption

max.

Smax

VA

50

Current consumption

max.

Imax

A

1.3

Fuse

Electronic overload protection and SMD fuse (soldered in)

Analog inputs

Command value

Voltage (differential input)

U

V

​0 ... ​10

Voltage (differential input)

Input resistance

R

kΩ

≥ 100

Solenoid outputs

Solenoid current

max.

Imax

A

1.9

Coil resistance at 20°C

R(20)

Ω

5.5

Clock frequency

command value-dependent

f

Hz

180 ... 450

Adjustment options

Solenoid current

I

A

0.1 ... 1.9

Zero point calibration

%

± 25

Ramp time up/down

t

s

0.16 … 5

Measuring sockets

Command value

"w"

U

V

0 ... 10

Actual current value

"I"

U

V

0 ... 1.9 (mV ≙ mA)

Displays

LED display

Green

Ready for operation

Supplementary information

Anschlussart

6 screw terminals

Mounting type

Top hat rail TH 35-7.5 according to EN 60715

Type of protection according to EN 60529

IP 20

Ambient temperature range

ϑ

°C

​0 … ​50

Storage temperature range

ϑ

°C

-25 … ​85

Weight

m

kg

0.15

For applications outside these parameters, please consult us!

Notice:

For information on the environment simulation testing for the areas of EMC (electro-magnetic compatibility), climate and mechanical load, see data sheet 30223-U.

Output characteristic curve

technical illustration-R901142360-Differential input for voltage Ramp generator with separately adjustable ramp times "up/down" Adjustable zero point and sensitivity Characteristic curve generator Clocked power output stage Dither generator LED displays for various operating states Reverse polarity protection for the operating voltage
technical illustration-R901142360-Differential input for voltage Ramp generator with separately adjustable ramp times "up/down" Adjustable zero point and sensitivity Characteristic curve generator Clocked power output stage Dither generator LED displays for various operating states Reverse polarity protection for the operating voltage

Measuring sockets

Command value

Actual current value (mV ≙ mA)

Reference potential

Potentiometer

Gw

Amplitude attenuator

Zw

Zero point

t <

Ramp time "Ramp up"

t >

Ramp time "Ramp down"

technical illustration-R901142360-Differential input for voltage Ramp generator with separately adjustable ramp times "up/down" Adjustable zero point and sensitivity Characteristic curve generator Clocked power output stage Dither generator LED displays for various operating states Reverse polarity protection for the operating voltage

Fuse

Suppressor diode

Power supply unit

Voltage input

Ramp generator

Zero point setting

Ramp time "Ramp up"

Ramp time "Ramp down"

Command value attenuator

Characteristic curve generator

Current controller

Clock generator

Schmitt trigger

Clocked output stage

Fault recognition

Measuring sockets

Dimensions in mm

technical illustration-R901142360-Differential input for voltage Ramp generator with separately adjustable ramp times "up/down" Adjustable zero point and sensitivity Characteristic curve generator Clocked power output stage Dither generator LED displays for various operating states Reverse polarity protection for the operating voltage

Dimensions in mm

technical illustration-R901142360-Differential input for voltage Ramp generator with separately adjustable ramp times "up/down" Adjustable zero point and sensitivity Characteristic curve generator Clocked power output stage Dither generator LED displays for various operating states Reverse polarity protection for the operating voltage

The amplifier module may only be wired when de-energized.

The distance to radios must be sufficient (>> 1 m).

Shield command value lines, do not lay them close to power cables, screen solenoid conductors.

Do not use free-wheeling diodes in the solenoid conductors.

With a strongly fluctuating operating voltage, it may in individual cases be necessary to use an external smoothing capacitor with a capacity of at least 2200 µF.

Recommendation: Capacitor module VT 11110 (see data sheet 30750); sufficient for up to 3 amplifier modules.