You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

BOSCH REXROTH
R901163576


$2,587.01 USD
  • BOSCH REXROTH
  • Material:R901163576
  • Model:4WPZ6E6X//ZV/12

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Bosch Rexroth directly.***
The Bosch Rexroth 4WPZ6E6X//ZV/12 (R901163576) is a high-quality, direct operated directional spool valve designed for precise control of fluid flow in hydraulic systems. This valve belongs to the WPZ series and is characterized by its ability to start, stop, and direct the flow of hydraulic fluid with great efficiency. The 4WPZ6E6X//ZV/12 model features a robust housing that incorporates one or two pneumatic actuation cylinders, a control spool, and return springs. The axial positioning of the ports for control provides ease of installation and maintenance. In its default state, when de-energized, the control spool is maintained in a central or initial position by the return springs unless an impulse spool is used. Upon activation, the pneumatic actuation elements move the control spool to achieve the desired flow direction. An important aspect of this model is the use of a throttle insert when needed to manage flows that exceed the valve's performance limit during switching processes. This insert is placed in channel P to ensure optimal operation under varying conditions. For applications requiring maintained spool positions without spring return, this valve can be equipped with detent as indicated by version ..OF.. Alternatively, version ..O.. offers configurations without return springs or detent for scenarios where a defined spool position in de-energized state is not necessary. The 4WPZ6E6X//ZV/12 operates pneumatically and conforms to DIN form A porting pattern without locating hole and ISO with locating hole standards for versatility across different systems. Subplates required for mounting are available separately. Additionally, it supports inductive position switches and proximity sensors for contactless detection of spool position. With component series X indicating its modern design iteration, this valve can withstand maximum operating pressures up to bar levels and handle maximum flow rates measured in liters per minute (l/min), ensuring reliable performance across various hydraulic applications.

General information

Valves of type WPZ are fluidically actuated directional spool valves. They control the start, stop and direction of a flow.

The directional valves basically consist of housing (1), one or two actuation elements (2) (pneumatic actuation cylinder), control spool (3) and one or two return springs (4). The ports for the control are positioned axially (6).

When de-energized, the control spool (3) is held in the central position or in the initial position by the return springs (4) (except impulse spool).

The control spool (3) is moved to the desired spool position by means of the actuation elements.

Throttle insert

The use of a throttle insert is required when due to prevailing operating conditions, flows can occur during the switching processes, which exceed the performance limit of the valve.

It is inserted in channel P of the directional valve.

Type 4WP 6 E6X/...

technical illustration-R901163576-Direct operated directional spool valve Operating methods: pneumatic Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Subplates see data sheet 45052 (separate order) Inductive position switch and proximity sensors (contactless)

Without spring return, with detent,

version ..OF/..

Directional valves with pneumatic actuation are also available as a 2-spool position valve with detent (7). If actuation elements with detent are used, each spool position can be locked.

Without spring return,

version ..O/..

If actuation elements without return springs and without detent are used, there is no defined spool position in the de-energized state.

Type 4WP 6 C6X/OF/N...

technical illustration-R901163576-Direct operated directional spool valve Operating methods: pneumatic Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Subplates see data sheet 45052 (separate order) Inductive position switch and proximity sensors (contactless)
technical illustration-R901163576-Direct operated directional spool valve Operating methods: pneumatic Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Subplates see data sheet 45052 (separate order) Inductive position switch and proximity sensors (contactless)

01

02

03

04

05

06

07

08

9

10

11

12

13

14

15

16

W

P

Z

6

6X

/

J

/

*

01

3 main ports

3

4 main ports

4

02

Directional valve

W

Type of actuation

03

pneumatic

P

04

Ports, axial

Z 1)

05

Size 6

6

06

Spool symbol, e. g. C, E, EA, EB etc.

2)

07

Component series 60 … 69 (60 … 69: unchanged installation and connection dimensions)

6X

08

With spring return

no code

Without spring return

O

Without spring return with detent

OF

09

Improved corrosion protection

3)

J

10

Without manual override

no code

With manual override

N3)

Spool position monitoring

7)

11

Without position switch

no code

Monitored spool position "a"

QMAG24

Monitored spool position "b"

QMBG24

Monitored rest position

QM0G24

12

Without throttle insert

no code

Throttle Ø 0.8 mm

B086)

Throttle Ø 1.0 mm

B106)

Throttle Ø 1.2 mm

B126)

Seal material

13

NBR seals

no code

FKM seals

V

Observe compatibility of seals with hydraulic fluid used. (Other seals upon request)

Clamping length

14

42 mm (standard)

no code

22 mm

Z

15

Without locating hole

no code

With locating hole

/605)

With locating hole and locking pin ISO 8752-3x8-St

/62

16

Further details in the plain text

*

Preferred types and standard units are specified in the EPS (standard price list).

Switching positions

2

3

Type WPZ

no code

O

OF

● = available

1) Not with version “N”
2) For symbols and example, see Symbols and Types of actuation
3) The external parts made of metal are galvanized, treated with an anti-corrosion agent or made of stainless steel. This design is also suitable for on-wall applications.
5) Locking pin ISO 8752-3 x 8-St, material no. R900005694, separate order
6) Use if volume flow > performance limits of the valve, effective in channel P.
7) Not for version “J”

general

Size

6

Weight (approx.)

Valve with one actuation cylinder

kg

1.8

Valve with two actuation cylinders

kg

2

Installation position 1)

any

Ambient temperature range

NBR seals

°C

-30 … +80

FKM seals

°C

-20 … +80
1) With version ../O.. (A, C and D) : horizontal

hydraulic

Size

6

Maximum operating pressure

Port P

bar

315

Port A

bar

315

Port B

bar

315

Port T 1)

bar

160

Maximum flow

l/min

60

Flow cross-section (spool position 0)

Symbol Q

mm2

approx. 6 % of nominal cross-section

Symbol W

mm2

approx. 3 % of nominal cross-section

Minimum pilot pressure 2)

bar

4

Maximum pilot pressure

bar

10

Pilot volume

cm³

4.24

Hydraulic fluid

see table

Hydraulic fluid temperature range

NBR seals

°C

-30 … +80

FKM seals

°C

-20 … +80

Viscosity range

mm²/s

2.8 … 500

Maximum admissible degree of contamination of the hydraulic fluid 3)

Class 20/18/15 according to ISO 4406 (c)

Maximum switching frequency

Hz

2
1) With symbols A and B, port T must be used as leakage oil connection if the operating pressure exceeds the admissible tank pressure.
2) See characteristic curves
3) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.

Hydraulic fluid

Classification

Suitable sealing materials

Standards

Mineral oil

HL, HLP

FKM, NBR

DIN 51524

Bio-degradable

Insoluble in water

HEES (synthetic esters)

FKM

VDMA 24568

HETG (rape seed oil)

FKM, NBR

Soluble in water

HEPG (polyglycols)

FKM

VDMA 24568

Other hydraulic fluids on request

Inductive position switch type QM: electrical connection

The electric connection is realized via a 4-pole mating connector (separate order) with connection thread M12 x 1.

electrical

Connection voltage (DC voltage)

V

24

Voltage tolerance (connection voltage)

+30 %/-15 %

Admissible residual ripple

%

≤ 10

Max. load capacity

mA

400

Switching outputs

technical illustration-R901163576-Direct operated directional spool valve Operating methods: pneumatic Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Subplates see data sheet 45052 (separate order) Inductive position switch and proximity sensors (contactless)
PNP transistor outputs, load between switching outputs and GND

Pinout

technical illustration-R901163576-Direct operated directional spool valve Operating methods: pneumatic Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Subplates see data sheet 45052 (separate order) Inductive position switch and proximity sensors (contactless)

1

V

24

2, 4

Switching output

mA

400

3

Earthing (GND)

V

0

For applications outside these parameters, please consult us!

(measured with HLP46, ϑOil = 40 ±5 °C)

Δp-qV characteristic curves

technical illustration-R901163576-Direct operated directional spool valve Operating methods: pneumatic Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Subplates see data sheet 45052 (separate order) Inductive position switch and proximity sensors (contactless)

Symbol

Direction of flow

P-A

P-B

A-T

B-T

A

3

3

B

3

3

C

1

1

3

1

D

5

5

3

3

E

3

3

1

1

F

1

3

1

1

G

6

6

9

9

H

2

4

2

2

J

1

1

2

1

L

3

3

4

9

M

2

4

3

3

P

3

1

1

1

Q

1

1

2

1

R

5

5

4

T

10

10

9

9

U

3

3

9

4

V

1

2

1

1

W

1

1

2

2

Y

5

5

3

3

Further characteristic curves:

7

Symbol “R” in switching position “b” (B → A)

8

Symbol “G” and “T” in central position (P → T)

9

Symbol “H” in central position (P → T)

Minimum pilot pressure dependent on the tank pressure

technical illustration-R901163576-Direct operated directional spool valve Operating methods: pneumatic Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Subplates see data sheet 45052 (separate order) Inductive position switch and proximity sensors (contactless)

At a higher tank pressure, the minimum pilot pressure has to be increased according to this diagram.

technical illustration-R901163576-Direct operated directional spool valve Operating methods: pneumatic Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Subplates see data sheet 45052 (separate order) Inductive position switch and proximity sensors (contactless)

Characteristic curve

Symbol

1

A, B

2

A/O, C, C/O, D, D/O, E, E1-, G, H, J, L, M, Q, U, W, und Y

3

F, P

4

R

5

T

6

V

technical illustration-R901163576-Direct operated directional spool valve Operating methods: pneumatic Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Subplates see data sheet 45052 (separate order) Inductive position switch and proximity sensors (contactless)
technical illustration-R901163576-Direct operated directional spool valve Operating methods: pneumatic Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Subplates see data sheet 45052 (separate order) Inductive position switch and proximity sensors (contactless)

Attention!

Caution in conjunction with differential cylinders due to pressure intensification!

technical illustration-R901163576-Direct operated directional spool valve Operating methods: pneumatic Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Subplates see data sheet 45052 (separate order) Inductive position switch and proximity sensors (contactless)
1) Example:
– Symbol E with spool position "a" → ordering code ..EA..
– Symbol E with spool position “b” → ordering code ..EB..
2) Symbol E1-: P → A/B pre-opening

Ordering code

Type of actuation

Symbol

Actuation side

Spool return

A, C, D

technical illustration-R901163576-Direct operated directional spool valve Operating methods: pneumatic Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Subplates see data sheet 45052 (separate order) Inductive position switch and proximity sensors (contactless)

../O..

technical illustration-R901163576-Direct operated directional spool valve Operating methods: pneumatic Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Subplates see data sheet 45052 (separate order) Inductive position switch and proximity sensors (contactless)

../OF..

technical illustration-R901163576-Direct operated directional spool valve Operating methods: pneumatic Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Subplates see data sheet 45052 (separate order) Inductive position switch and proximity sensors (contactless)

B, Y

technical illustration-R901163576-Direct operated directional spool valve Operating methods: pneumatic Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Subplates see data sheet 45052 (separate order) Inductive position switch and proximity sensors (contactless)

E, F

G, H

J, L

M, P

Q, R

T, U

V, W

a = A

technical illustration-R901163576-Direct operated directional spool valve Operating methods: pneumatic Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Subplates see data sheet 45052 (separate order) Inductive position switch and proximity sensors (contactless)

b = B

technical illustration-R901163576-Direct operated directional spool valve Operating methods: pneumatic Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Subplates see data sheet 45052 (separate order) Inductive position switch and proximity sensors (contactless)
technical illustration-R901163576-Direct operated directional spool valve Operating methods: pneumatic Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Subplates see data sheet 45052 (separate order) Inductive position switch and proximity sensors (contactless)

Dimensions in mm

technical illustration-R901163576-Direct operated directional spool valve Operating methods: pneumatic Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Subplates see data sheet 45052 (separate order) Inductive position switch and proximity sensors (contactless)
technical illustration-R901163576-Direct operated directional spool valve Operating methods: pneumatic Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Subplates see data sheet 45052 (separate order) Inductive position switch and proximity sensors (contactless)

Required surface quality of the valve contact surface

1

Valve with 2 spool positions and 2 actuation cylinders

Valve with 3 spool positions and 2 actuation cylinders

2

Actuation cylinder “a”

3

Actuation cylinder “b”

4

Plug screw for valve with 1 actuation cylinder (2 spool positions)

6

Same seal rings for ports A, B, P, T

7

Name plate

8

Porting pattern according toISO 4401-03-02-0-05 (with locating hole for locking pin ISO 8752-3x8-St, material no. R900005694, separate order)

9

Connection with version “WP”

10

Port with version “WPZ”

11

Alternative clamping length (): 22 mm

Subplates according to data sheet 45052 (separate order)

(without locating hole)

G 341/01 (G1/4)

G 342/01 (G3/8)

G 502/01 (G1/2)

(with locating hole)

G 341/60 (G1/4)

G 342/60 (G3/8)

G 502/60 (G1/2)

G 341/12 (SAE-6)1)

G 342/12 (SAE-8)1)

G 502/12 (SAE-10)1)

 

1) On request

 

 

Valve mounting screws (separate order)

Clamping length 42 mm:

4 hexagon socket head cap screws, metric

ISO 4762-M5 x 50-10.9-flZn-240h-L

(friction coefficient μtotal = 0.09 to 0.14);

tightening torque MA = 7 Nm ± 10 %,

material no. R913000064

or

4 hexagon socket head cap screws

ISO 4762-M5 x 50-10.9 (self procurement)

(friction coefficient μtotal = 0.12 to 0.17);

tightening torque MA = 8.1 Nm ± 10 %

4 hexagon socket head cap screws UNC

10-24 UNC x 2″ ASTM-A574

(friction coefficient μtotal = 0.19 to 0.24);

tightening torque MA = 11 Nm± 15 %,

(friction coefficient μtotal = 0.12 to 0.17);

tightening torque MA = 8 Nm ± 10 %,

material no. R978800693

Clamping length 22 mm:

4 hexagon socket head cap screws, metric

ISO 4762-M5 x 30-10.9-flZn-240h-L

(friction coefficient μtotal= 0.09 to 0.14);

tightening torque MA = 7 Nm ± 10 %,

material no. R913000316

or

4 hexagon socket head cap screws

ISO 4762-M5 x 30-10.9 (self procurement)

(friction coefficient μtotal = 0.12 to 0.17);

tightening torque MA = 8.1 Nm± 10 %

4 hexagon socket head cap screws UNC

10-24 UNC x 1 1/4 ″

(friction coefficient μtotal = 0.19 to 0.24);

tightening torque MA = 11 Nm± 15 %,

(friction coefficient μtotal = 0.12 to 0.17);

tightening torque MA = 8 Nm± 10 %,

material no. R978802879

Spool position monitoring

Inductive position switch type QM

Dimensions in mm

technical illustration-R901163576-Direct operated directional spool valve Operating methods: pneumatic Porting pattern according to DIN 24340 form A (without locating hole) Porting pattern according to ISO 4401-03-02-0-05 (with locating hole) Subplates see data sheet 45052 (separate order) Inductive position switch and proximity sensors (contactless)
1) For dimensions, see valve dimensions

Notice:

The dimensions are nominal dimensions which are subject to tolerances.