You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

BOSCH REXROTH
R901220877


$719.03 USD
  • BOSCH REXROTH
  • Material:R901220877

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.


Unpacked Weight: 0.451601 kg

General information

Pressure valves type KAV are pilot-operated pressure cut-off valves with steplessly adjustable switching pressure differentials.

They basically consist of pilot control stage (1) and main stage (2).

Function

The pump flow (main port ➀) is introduced into the accumulator of the system via main port ➂. If the pressure at the actuator in main port ➂ exceeds the set top switching pressure, the connection to Y (main port ➃) and T (main port ➁) is opened and the pump flow is switched to depressurized circulation (➀ to ➁). If the pressure at the actuator in main port ➂ falls below the set bottom switching pressure, the connection to Y (main port ➃) and T (main port ➁) is closed and the pump flow is directed back into the accumulator of the system.

If used as accumulator charging valve, an additional check valve (7) is required to block the connection from main port ➂ to main port ➀ to prevent return flow of the accumulator volume.

If used for depressurized pump start-up, an additional bore Z is required in the mounting cavity (see mounting cavity) for use of port Z at the valve. Between Z and Y (main port ➃), a directional valve (8) is to be switched to enable remote-controlled shut-off (from main port ➀ to main port ➁) under the set switching pressure.

Setting the switching pressure differential:

Notice! At the factory, the valves are set at nominal pressure to a switching pressure differential of approx. 10 % to 12 %. A setting of 8 % to 50 % of the nominal pressure is possible.

On delivery, the adjustment spindle (3) is set to the minimum adjustable top switching pressure, i.e., the adjustment spindle is screwed out up to the limit stop. By screwing in the adjustment spindle (3), the top switching pressure may be increased. By screwing in the adjustment spindle (4), the bottom switching pressure is increased and the switching pressure differential reduced. Screwing out the adjustment spindle (4) reduced the bottom switching pressure and the switching pressure differential is increased. The pressure adjustment is secured by means of the clamping screw (6) and the lock nut (5).

Possible setting range, refer to characteristic curve "switching pressure differential".

technical illustration-R901220877-Mounting cavity R/KAV.2 High switching capacity Available in 4 pressure ratings (50, 100, 200, 350 bar) Infinitely variable switching pressure differential Hexagon with protective cap Pilot unit with main spool

➀

Main port 1 (P)

➁

Main port 2 (T)

➂

Main port 3 (X, A)

➃

Main port 4 (Y)

1) Port Z can be applied in case of use for depressurized pump start-up in connection with a directional valve (see mounting cavity).

Screw-in cartridge valve
Maximum operating pressure 350 bar (5000 psi)
Maximum flow 140 l/min (37 gpm)
Cavity R/KAV.2 (thread 1“-14 UNS-2B)
Max. pressure350
Adjustment optionsHexagon with protective cap
Product family classificationPressure cut-off valve, pilot operated, with mechanical actuation
Productgroup ID9,10,11,12,13,14
Product family typeKAV
Ports number4
Sealing materialNBR
CavityR/KAV.2 (thread 1“-14 UNS-2B)
Product typeKAV
Max. flow140
Type of connectionScrew-in cartridge valve
Normal positionNormally closed
Nominal flow140
Pressure pre-settingWithout pressure pre-setting
Direct - PilotPilot operated
Product familyCut-off
Spool PoppetPoppet type
Weight0.451601
Hydraulic fluidHL,HLP

01

02

03

04

05

06

07

08

09

10

11

KAV

2

2

A

A

/

A

–

V

01

Pressure cut-off valve, pilot-operated

KAV

Adjustment type

02

Hexagon with protective cap

2

Pressure rating

03

50 bar

C

100 bar

F

200 bar

K

350 bar

R

04

Component size

2

05

4 main ports

Symbol

technical illustration-R901220877-Mounting cavity R/KAV.2 High switching capacity Available in 4 pressure ratings (50, 100, 200, 350 bar) Infinitely variable switching pressure differential Hexagon with protective cap Pilot unit with main spool

A

06

Component series

A

07

High Performance and mounting cavity R/KAV.2 (see circuit diagrams)

A

08

without pressure pre-adjustment

no code

with pressure pre-adjustment

–

with pressure pre-adjustment, sealed

P

 

09

top switching pressure in bar

1)

...

10

bottom switching pressure in bar →

1)

...

Seal material

11

FKM seals

V

1) Please enter values, refer to characteristic curve "switching pressure differential"; only required for version with pressure pre-adjustment ("–" or "P"):
Pressure adjustment is realized at
a pump flow of approx. 10 l/min
actuator flow approx. 2 l/min

general

Size

2

Weight

kg

0.42

Installation position

any

hydraulic

Size

2

Maximum operating pressure

bar

350

Maximum set pressure

Version "C"

bar

50

Version "F"

bar

100

Version "K"

bar

200

Version "R"

bar

350

Maximum admissible return flow pressure

Main port ➁ (T)

bar

200

Main port ➃ (Y) 1)

bar

100

Maximum flow

l/min

140

Hydraulic fluid

see table

Hydraulic fluid temperature range

°C

-20 … +80

Viscosity range

mm²/s

10 … 800

Maximum admissible degree of contamination of the hydraulic fluid 2)

Class 20/18/15 according to ISO 4406 (c)

Load cycles

million

10
1) Attention! The applied pressure adds to the set pressure! The switching pressure differential remains unchanged within the setting range!
2) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.

Hydraulic fluid

Classification

Suitable sealing materials

Standards

Mineral oil

HL, HLP

FKM, NBR

DIN 51524

Bio-degradable

Insoluble in water

HEES (synthetic esters)

FKM

VDMA 24568

HETG (rape seed oil)

FKM, NBR

Soluble in water

HEPG (polyglycols)

FKM

VDMA 24568

Other hydraulic fluids on request

For applications outside these parameters, please consult us!

(measured at HLP46, ϑoil=50±5 °C)

Circulation pressure dependent on the pump flow qV P

technical illustration-R901220877-Mounting cavity R/KAV.2 High switching capacity Available in 4 pressure ratings (50, 100, 200, 350 bar) Infinitely variable switching pressure differential Hexagon with protective cap Pilot unit with main spool

Switching pressure differential (P → X)

technical illustration-R901220877-Mounting cavity R/KAV.2 High switching capacity Available in 4 pressure ratings (50, 100, 200, 350 bar) Infinitely variable switching pressure differential Hexagon with protective cap Pilot unit with main spool
technical illustration-R901220877-Mounting cavity R/KAV.2 High switching capacity Available in 4 pressure ratings (50, 100, 200, 350 bar) Infinitely variable switching pressure differential Hexagon with protective cap Pilot unit with main spool

➀

Main port 1 (P)

➁

Main port 2 (T)

➂

Main port 3 (X, A)

➃

Main port 4 (Y)

1

Always keep open! Only close for maintenance!

2

Always keep closed! Only open for maintenance!

Circuit examples

Hydraulic system with pressure accumulator

technical illustration-R901220877-Mounting cavity R/KAV.2 High switching capacity Available in 4 pressure ratings (50, 100, 200, 350 bar) Infinitely variable switching pressure differential Hexagon with protective cap Pilot unit with main spool

Circuit examples

Hydraulic system with high- and low-pressure pump

technical illustration-R901220877-Mounting cavity R/KAV.2 High switching capacity Available in 4 pressure ratings (50, 100, 200, 350 bar) Infinitely variable switching pressure differential Hexagon with protective cap Pilot unit with main spool

Circuit examples

Hydraulic system with pressure accumulator with directional valve (not included in the scope of delivery!)

technical illustration-R901220877-Mounting cavity R/KAV.2 High switching capacity Available in 4 pressure ratings (50, 100, 200, 350 bar) Infinitely variable switching pressure differential Hexagon with protective cap Pilot unit with main spool

➀

Main port 1 (P)

➁

Main port 2 (T)

➂

Main port 3 (X, A)

➃

Main port 4 (Y)

1

Always keep open! Only close for maintenance!

2

Always keep closed! Only open for maintenance!

Circuit examples

Hydraulic system with high- and low-pressure pump with directional valve (not included in the scope of delivery!)

technical illustration-R901220877-Mounting cavity R/KAV.2 High switching capacity Available in 4 pressure ratings (50, 100, 200, 350 bar) Infinitely variable switching pressure differential Hexagon with protective cap Pilot unit with main spool

Application note!

Reduce the tubing between pressure cut-off valve and hydraulic accumulator to a minimum!

Dimensions in mm

technical illustration-R901220877-Mounting cavity R/KAV.2 High switching capacity Available in 4 pressure ratings (50, 100, 200, 350 bar) Infinitely variable switching pressure differential Hexagon with protective cap Pilot unit with main spool

➀

Main port 1 (P)

➁

Main port 2 (T)

➂

Main port 3 (X, A)

➃

Main port 4 (Y)

1

Hexagon SW32, tightening torque MA = 60 Nm

2

Adjustment type "2", hexagon with protective cap SW19

3

Hexagon SW10

4

Internal hexagon SW3

5

Locating screw SW2

➀

Main port 1 (P)

➁

Main port 2 (T)

➂

Main port 3 (X, A)

➃

Main port 4 (Y)

1) Port Z can be applied in case of use for depressurized pump start-up in connection with a directional valve (see mounting cavity).
1) With counterbore
2) Depth of fit
3) All O-ring insertion faces are rounded and free of burrs
4 Bore Z required in case of use for depressurized pump start-up in connection with a directional valve

Mounting cavity R/KAV.2: 4 main ports; thread 1"-14 UNS-2B

Dimensions in mm

technical illustration-R901220877-Mounting cavity R/KAV.2 High switching capacity Available in 4 pressure ratings (50, 100, 200, 350 bar) Infinitely variable switching pressure differential Hexagon with protective cap Pilot unit with main spool

➀

Main port 1 (P)

➁

Main port 2 (T)

➂

Main port 3 (X, A)

➃

Main port 4 (Y)

1

Hexagon SW32, tightening torque MA = 60 Nm

2

Adjustment type "2", hexagon with protective cap SW19

3

Hexagon SW10

4

Internal hexagon SW3

5

Locating screw SW2

➀

Main port 1 (P)

➁

Main port 2 (T)

➂

Main port 3 (X, A)

➃

Main port 4 (Y)

1) With counterbore
2) Depth of fit
3) All O-ring insertion faces are rounded and free of burrs
4 Bore Z required in case of use for depressurized pump start-up in connection with a directional valve

Tolerance for all angles ± 0.5 °