BOSCH REXROTH
R901254693

  • BOSCH REXROTH
  • Material:R901254693
  • Model:VT-HNC100-4-3X/P-I-E0/000

Due to extremely high demand, please call 877-366-7226 for availability

***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Bosch Rexroth directly.***
The Bosch Rexroth VT-HNC100-4-3X/P-I-E0/000 (R901254693) is a highly versatile hydraulic drive control unit that offers exceptional flexibility and integration capabilities for various applications. It features a scalable design in both hardware and software, making it suitable for a range of requirements, from simple to complex hydraulic drive systems. This model is robust and designed for remote applications, ensuring reliable performance in diverse operating conditions. The VT-HNC100-4-3X/P-I-E0/000 excels in its ease of use, offering consistent application through its user-friendly interface. It is equipped with free programmability and supports a variety of interfaces, allowing seamless integration into different control architectures. The unit is compatible with open loop and closed loop control technology, as well as drive technology. Bosch Rexroth's commitment to open standards is evident in the VT-HNC100-4-3X/P-I-E0/000's support for commonly used fieldbus and Ethernet protocols, which ensures compatibility with multiple automation environments. The unit boasts best-in-class control strategies that have been optimized based on Rexroth's extensive knowledge of hydraulics and motion control interaction. This controller can manage up to 4 axes and offers a range of control options including position, force, pressure, velocity controls, as well as alternating position-pressure or position-force controls. It also features path-dependent deceleration and synchronization capabilities using master-slave or mean principle methods. For connectivity purposes, it includes bus connections like Sercos, PROFINET RT, EtherNet/IP. Actual value detection can be done through incremental positional transducers or absolute SSI positional transducers. Analog inputs range from 0 to 10 V and 4 to 20 mA with actuating variable output available in voltage or current form. For service interfaces, it comes equipped with RS232 with an optional TCP/IP interface available. Additionally, the VT-HNC100-4-3X/P-I-E0/000 complies with CE conformity according to the EMC directive EC and supports the WinPed operating software for efficient engineering implementation. However, it should be noted that it is not released for Windows CE platforms.

Scalablein hardware and software (scalable, remote, robust)

The HNC100 is Rexroth's "all-rounder" in hydraulic drive control. Thanks to its distinct interface variety and free programmability, it fulfills various requirements and can be easily and flexibly integrated into any control architecture.

 

Consistent easy application.

Rexroth is the specialist for hydraulic systems – from open loop and closed loop control technology to drive technology. We provide you easily and quickly with our expertise. WinPed7 is the solution. The software tool ensures powerful engineering for an easy and quick implementation of your application.

 

Open to any solution

Regarding control solutions for hydraulic drives, Rexroth also consistently focus on open interfaces and programming standards. The Motion Controls support any commonly used field bus and Ethernet protocol and fit in seamlessly with various automation environments.

 

Best-in-class hydraulic controllers:

Rexroth has gathered unique knowledge of the interaction of hydraulics and Motion Control technology. Based on this knowledge, the control strategies for hydraulic and hybrid drives have been optimized and are represented in immediately usable software.

01

02

03

04

05

06

07

VT-HNC100

–

–

3X

/

–

–

/

01

VT-HNC100

Serial unit

02

Version Compact for 1 axis

C

Version for 1 hydraulic axis

1

Versions for 2 hydraulic axes

2

Versions for 3 hydraulic axes

3

Versions for 4 hydraulic axes

4

03

Component series 30 ... 39 (30 ... 39: unchanged technical data and pin assignment)

3X

Bus connection

2)

04

PROFIBUS DP

P

CANopen

C

PROFINET RT (not in connection with Compact version)

N

EtherNet/IP (not in connection with Compact version)

E

Position transducer

05

Incremental/SSI (not in connection with Compact version)

I

SSI (only in connection with Compact version)

S

06

no fitting

00

TCP/IP

1)

E0

Option

07

without synchronism

G00

Synchronism 2-axis version

G02

Synchronism 3-axis version

G03

Synchronism 4-axis version

G04

1) Only specify "E0" if the Ethernet service interface is desired for "PROFIBUS DP"
2) Versions without bus connections are not available.

General

Type / version

VT-HNC100-C-3X VT-HNC100-1-3X VT-HNC100-2-3X VT-HNC100-3-3X VT-HNC100-4-3X

Component series

3X

Voltage supply

Type / version

VT-HNC100-C-3X VT-HNC100-1-3X VT-HNC100-2-3X VT-HNC100-3-3X VT-HNC100-4-3X

Operating voltage 1)

UB

18 to 30 VDC, residual ripple < 1.5 V

Current consumption at 24 VDC

I

approx. 500 mA 1 to 4 A (depending on the HNC variant and the also supplied components)
1) If a 24 V encoder supply is implemented directly via the VT-HNC100...3X (supply voltage is looped in), the encoder specification has to be observed.

Analog inputs (AI)

Type / version

VT-HNC100-C-3X

Voltage input (reference to AGND - Analog ground)

Channel number

1

Input voltage

UE

max. +12 V to –12 V (+10 V to –10 V measurable)

Input resistance

RE

200 kΩ ± 5 %

Resolution

5 mV

Non-linearity

%

< 0.2

Calibration tolerance, max. 1)

40 mV (with factory settings)

Current inputs

Channel number

2

Input current

IE

4 mA to 20 mA

Input resistance

RE

225 Ω at 20 °C (100 Ω measuring resistance)

Leakage current

IV

0.1 to 0.4 % (with 100 Ω between pin 2 or pin 3 (Cin1+ or Cin2+) and "AGND"

Resolution

5 μA

Voltage supply for analog sensors via VT-HNC100-C-3X

UB at X2A, pin 7 (+24 Vsens)
1) If the factory settings are insufficient, the measurement technology can be calibrated on site via software in a system-specific way.

Analog inputs (AI) per axis electronics

Type / version

VT-HNC100-1-3X VT-HNC100-2-3X VT-HNC100-3-3X VT-HNC100-4-3X

Voltage inputs (differential inputs)

Channel number

2

Input voltage

UE

max. +12 V to –12 V (+10 V to –10 V measurable)

Input resistance

RE

200 kΩ ± 5 %

Resolution

5 mV

Non-linearity

%

< 0.2

Calibration tolerance, max. 1)

40 mV (with factory settings)

Current inputs

Channel number

2

Input current

IE

4 mA to 20 mA

Input resistance

RE

350 Ω at 20 °C (100 Ω measuring resistance)

Leakage current

IV

0.1 to 0.4 %

Resolution

5 μA

Voltage supply for analog sensors via VT-HNC100…3X

U

UB at X2A1 to X2A4, pin 14 (+24 Vsens)
1) If the factory settings are insufficient, the measurement technology can be calibrated on site via software in a system-specific way.

Digital inputs (DI)

Type / version

VT-HNC100-C-3X VT-HNC100-1-3X VT-HNC100-2-3X VT-HNC100-3-3X VT-HNC100-4-3X

Switching inputs (DI)

Number

4 11

Logic level

log 0 (low) ≤ 5 V; log 1 (high) ≥ 10 V to UB, Ie = 20 mA at UB = 24 V

Connection

flexible conductor up to 1.5 mm2

Reference potential for all signals

DGND

Analog outputs (AO)

Type / version

VT-HNC100-C-3X

Voltage outputs

Channel number

2

Output voltage, normalized

Unorm

–10 V to +10 V (max. –10.7 V to +10.7 V)

Output current, max.

Imax

± 10 mA

Load, min.

Rmin

kΩ

1

Resolution

1.25 mV

Non-linearity

in the range –9.5 V to +9.5 V

%

< 0.1

in the range –10 V to –9.5 V and +9.5 V to +10 V

%

< 0.2

Analog outputs (AO) per axis electronics

Type / version

VT-HNC100-1-3X VT-HNC100-2-3X VT-HNC100-3-3X VT-HNC100-4-3X

Analog outputs (AO: 1) per axis electronics 1)

2

Non-linearity

in the range –9.5 V to +9.5 V

%

< 0.1

in the range –10 V to –9.5 V and +9.5 V to +10 V

%

< 0.2

Voltage output

Output voltage, normalized

Unorm

–10 V to +10 V (max. –10.7 V to +10.7 V)

Output current, max.

Imax

± 10 mA

Load, min.

Rmin

kΩ

1

Residual ripple

±60 mV (without noise)

Resolution

1.25 mV

Current output

Output current, normalized

Inorm

4 mA to 20 mA

Load, max.

Rmax

Ω

500

Resolution

0.625 μA
1) Configurable as current or voltage output. Axis electronics slot 1 and axis electronics slot 2 feature two voltage outputs Vout1 and Vout2. Axis electronics slot 3 and axis electronics slot 4 feature one voltage output Vout1.

Digital outputs (DO)

Type / version

VT-HNC100-C-3X VT-HNC100-1-3X VT-HNC100-2-3X VT-HNC100-3-3X VT-HNC100-4-3X

Switching outputs (DO)

Number

2 11

Logic level

log 0 (low) ≤ 2 V; log 1 (high) ≤ UB; Imax = 20 mA, maximum load capacity C = 0.047 μF

Connection

flexible conductor up to 1.5 mm2

Reference potential for all signals

DGND

Digital position transducers (encoders):

Type / version

VT-HNC100-C-3X

SSI transducer 1)

Coding

Gray code

Data width

adjustable up to max. 28 bit

Line receiver/driver

RS485

Voltage supply via VT-HNC100-C-3X

U

UB

Reference potential for all signals

EGND
1) Due to the higher control quality, an SSI transducer with clock synchronization should be used

Digital position transducers (encoders) per axis electronics

Type / version

VT-HNC100-1-3X VT-HNC100-2-3X VT-HNC100-3-3X VT-HNC100-4-3X

Incremental transducer with TTL output

Input voltage

log 0

0 to 1 V

log 1

2.8 to 5.5 V

Input current

log 0

-0.8 mA (with 0 V)

log 1

0.8 mA (with 5 V)

Frequency, max. related to Ua1

fmax

kHz

250

Voltage supply for incremental transducers via VT-HNC100…3X

U

5.25 V ±1 %, max. 400 mA total current over all axes at X8M1 to X8M4, Pin 12 (+5 Venc)

SSI transducer 1)

Coding

Gray code

Data width

adjustable up to max. 28 bit

Line receiver/driver

RS485

Voltage supply for SSI transducers via VT-HNC100…3X

U

UB at X8M1 to X8M4, pin 14 (+24 Venc)

Reference potential for all signals

EGND
1) Due to the higher control quality, an SSI transducer with clock synchronization should be used

Other information

Type / version

VT-HNC100-C-3X VT-HNC100-1-3X VT-HNC100-2-3X VT-HNC100-3-3X VT-HNC100-4-3X

Processor

32 bit power PC

Interface for WIN-PED 6, WIN-PED7

RS232

Bus interface

PROFIBUS DP (max. 12 MBaud acc. to IEC 61158), CANopen RS232, optional TCP/IP
PROFIBUS DP (max. 12 MBaud acc. to IEC 61158), CANopen, PROFINET RT, EtherNet/IP

Installation

Top hat rail TH 35-7.5 or TH 35-15 according to EN 60715

Admissible operating temperature range

ϑ

°C

​0 … +50

Storage temperature range

ϑ

°C

-20 … +70

Protection class according to EN 60529:1991

IP 20

Weight

m

g

440 585 690 850 960

m

223 g 1)

CE conformity

See features
1) with Ethernet, in addition

PROFINET RT, EtherNet/IP

Type / version

VT-HNC100-1-3X VT-HNC100-2-3X VT-HNC100-3-3X VT-HNC100-4-3X

Minimum cycle time

ms

2

Size of the cyclic I/O data, max.

992 byte (max. 496 byte per direction)

Transmission rate

100 Mbits/s, full-duplex

For applications outside these parameters, please consult us!

System overview (example)

technical illustration-R901254693-For controlling 1 to 4 axes NC programming WinPed 7 operating software<br>
Not released for Windows 10! CE conformity according to EMC directive 2004/108/EC Freely configurable controller variants<br>
- Position control<br>
- Force control<br>
- Pressure control<br>
- Alternating position/pressure or position/force controls<br>
- Velocity control<br>
- Path-dependent decelerating<br>
- Synchronism (master/slave or mean principle) Bus connection (Sercos, PROFINET RT, EtherNet/IP) Actual value detection<br>
- Positional transducer: Incremental<br>
- Positional transducer: Absolute (SSI)<br>
‑ Analog 0 to ±10 V and 0 (4) to 20 mA Actuating variable output: voltage or current Service interface: RS232, optional TCP/IP

System overview, interfaces (example)

technical illustration-R901254693-For controlling 1 to 4 axes NC programming WinPed 7 operating software<br>
Not released for Windows 10! CE conformity according to EMC directive 2004/108/EC Freely configurable controller variants<br>
- Position control<br>
- Force control<br>
- Pressure control<br>
- Alternating position/pressure or position/force controls<br>
- Velocity control<br>
- Path-dependent decelerating<br>
- Synchronism (master/slave or mean principle) Bus connection (Sercos, PROFINET RT, EtherNet/IP) Actual value detection<br>
- Positional transducer: Incremental<br>
- Positional transducer: Absolute (SSI)<br>
‑ Analog 0 to ±10 V and 0 (4) to 20 mA Actuating variable output: voltage or current Service interface: RS232, optional TCP/IP

1

Differential cylinder

2

integrated position measurement system

3

Proportional servo valve with integrated control electronics

4

VT-HNC100-1-3X/N...

5

Connection cable

6

Pressure transducer

7

Sandwich plate shut-off valve (with connector switching amplifier)

technical illustration-R901254693-For controlling 1 to 4 axes NC programming WinPed 7 operating software<br>
Not released for Windows 10! CE conformity according to EMC directive 2004/108/EC Freely configurable controller variants<br>
- Position control<br>
- Force control<br>
- Pressure control<br>
- Alternating position/pressure or position/force controls<br>
- Velocity control<br>
- Path-dependent decelerating<br>
- Synchronism (master/slave or mean principle) Bus connection (Sercos, PROFINET RT, EtherNet/IP) Actual value detection<br>
- Positional transducer: Incremental<br>
- Positional transducer: Absolute (SSI)<br>
‑ Analog 0 to ±10 V and 0 (4) to 20 mA Actuating variable output: voltage or current Service interface: RS232, optional TCP/IP
technical illustration-R901254693-For controlling 1 to 4 axes NC programming WinPed 7 operating software<br>
Not released for Windows 10! CE conformity according to EMC directive 2004/108/EC Freely configurable controller variants<br>
- Position control<br>
- Force control<br>
- Pressure control<br>
- Alternating position/pressure or position/force controls<br>
- Velocity control<br>
- Path-dependent decelerating<br>
- Synchronism (master/slave or mean principle) Bus connection (Sercos, PROFINET RT, EtherNet/IP) Actual value detection<br>
- Positional transducer: Incremental<br>
- Positional transducer: Absolute (SSI)<br>
‑ Analog 0 to ±10 V and 0 (4) to 20 mA Actuating variable output: voltage or current Service interface: RS232, optional TCP/IP
technical illustration-R901254693-For controlling 1 to 4 axes NC programming WinPed 7 operating software<br>
Not released for Windows 10! CE conformity according to EMC directive 2004/108/EC Freely configurable controller variants<br>
- Position control<br>
- Force control<br>
- Pressure control<br>
- Alternating position/pressure or position/force controls<br>
- Velocity control<br>
- Path-dependent decelerating<br>
- Synchronism (master/slave or mean principle) Bus connection (Sercos, PROFINET RT, EtherNet/IP) Actual value detection<br>
- Positional transducer: Incremental<br>
- Positional transducer: Absolute (SSI)<br>
‑ Analog 0 to ±10 V and 0 (4) to 20 mA Actuating variable output: voltage or current Service interface: RS232, optional TCP/IP
technical illustration-R901254693-For controlling 1 to 4 axes NC programming WinPed 7 operating software<br>
Not released for Windows 10! CE conformity according to EMC directive 2004/108/EC Freely configurable controller variants<br>
- Position control<br>
- Force control<br>
- Pressure control<br>
- Alternating position/pressure or position/force controls<br>
- Velocity control<br>
- Path-dependent decelerating<br>
- Synchronism (master/slave or mean principle) Bus connection (Sercos, PROFINET RT, EtherNet/IP) Actual value detection<br>
- Positional transducer: Incremental<br>
- Positional transducer: Absolute (SSI)<br>
‑ Analog 0 to ±10 V and 0 (4) to 20 mA Actuating variable output: voltage or current Service interface: RS232, optional TCP/IP
technical illustration-R901254693-For controlling 1 to 4 axes NC programming WinPed 7 operating software<br>
Not released for Windows 10! CE conformity according to EMC directive 2004/108/EC Freely configurable controller variants<br>
- Position control<br>
- Force control<br>
- Pressure control<br>
- Alternating position/pressure or position/force controls<br>
- Velocity control<br>
- Path-dependent decelerating<br>
- Synchronism (master/slave or mean principle) Bus connection (Sercos, PROFINET RT, EtherNet/IP) Actual value detection<br>
- Positional transducer: Incremental<br>
- Positional transducer: Absolute (SSI)<br>
‑ Analog 0 to ±10 V and 0 (4) to 20 mA Actuating variable output: voltage or current Service interface: RS232, optional TCP/IP

Dimensions in mm

technical illustration-R901254693-For controlling 1 to 4 axes NC programming WinPed 7 operating software<br>
Not released for Windows 10! CE conformity according to EMC directive 2004/108/EC Freely configurable controller variants<br>
- Position control<br>
- Force control<br>
- Pressure control<br>
- Alternating position/pressure or position/force controls<br>
- Velocity control<br>
- Path-dependent decelerating<br>
- Synchronism (master/slave or mean principle) Bus connection (Sercos, PROFINET RT, EtherNet/IP) Actual value detection<br>
- Positional transducer: Incremental<br>
- Positional transducer: Absolute (SSI)<br>
‑ Analog 0 to ±10 V and 0 (4) to 20 mA Actuating variable output: voltage or current Service interface: RS232, optional TCP/IP

1

Installation on top hat rail TH 35-7.5 or TH 35-15 according to EN 60715

Dimensions in mm

technical illustration-R901254693-For controlling 1 to 4 axes NC programming WinPed 7 operating software<br>
Not released for Windows 10! CE conformity according to EMC directive 2004/108/EC Freely configurable controller variants<br>
- Position control<br>
- Force control<br>
- Pressure control<br>
- Alternating position/pressure or position/force controls<br>
- Velocity control<br>
- Path-dependent decelerating<br>
- Synchronism (master/slave or mean principle) Bus connection (Sercos, PROFINET RT, EtherNet/IP) Actual value detection<br>
- Positional transducer: Incremental<br>
- Positional transducer: Absolute (SSI)<br>
‑ Analog 0 to ±10 V and 0 (4) to 20 mA Actuating variable output: voltage or current Service interface: RS232, optional TCP/IP

1

Installation on top hat rail TH 35-7.5 or TH 35-15 according to EN 60715