BOSCH REXROTH
R901259666
- BOSCH REXROTH
- Material:R901259666
- Model:4WRVE25V370L-2X/G24K0/B5M
Quantity in stock: 0
The Bosch Rexroth 4WRVE25V370L-2X/G24K0/B5M (R901259666) is a high-response directional control valve designed for precise operation in hydraulic systems. This model features integrated electronics OBE with a position controller for both the pilot and main stage, ensuring accurate and responsive control. The valve is calibrated at the plant, which guarantees optimal performance right from the start. As a servo quality valve, the 4WRVE25V370L-2X/G24K0/B5M offers superior reliability and smooth operation, making it suitable for applications where precision is critical. It includes a control spool and sleeve that are engineered to deliver high responsiveness under varying conditions. The main stage of the valve also comes with position feedback, which contributes to its precise control capabilities. The flow characteristics of this Bosch Rexroth valve can be tailored to specific application needs; it offers M (Progressive and fine control edge), P (Inflected characteristic curve), and L (Linear) options to suit various system requirements. This flexibility allows for customization according to the unique demands of each application. With a maximum operating pressure of 'bar' and a nominal flow rate of 'l/min', the 4WRVE25V370L-2X/G24K0/B5M is built to handle demanding tasks while maintaining efficiency and performance. Its size and component series X further denote its suitability for integration into a wide range of hydraulic circuits where high-response control is essential.
Valves of type 4WRVE are pilot-operated high-response valves in servo quality.
|
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
10 |
11 |
12 |
13 |
14 |
|||
|
4 |
WRV |
E |
‒ |
2X |
/ |
G24 |
K0 |
/ |
B5 |
M |
* |
|
01 |
4 main ports |
4 |
|
02 |
High-response directional valve, pilot operated |
WRV |
|
03 |
With integrated electronics (OBE) |
E |
|
04 |
Size 10 |
10 |
|
Size 16 |
16 |
|
|
Size 25 |
25 |
|
|
Size 27 |
27 1) |
|
|
05 |
Symbols; for the possible version, see "Symbols/Circuit diagrams" |
V, V1 |
|
Rated flow (Δp = 5 bar) |
||
|
06 |
Size 10 |
|
|
40 l/min |
40 2) |
|
|
55 l/min |
55 3) |
|
|
70 l/min |
70 2) |
|
|
85 l/min |
85 3) |
|
|
Size 16 |
||
|
90 l/min |
90 2) |
|
|
120 l/min |
120 3) |
|
|
150 l/min |
150 2) |
|
|
200 l/min |
200 3) |
|
|
Size 25 |
||
|
300 l/min |
300 2) |
|
|
370 l/min |
370 3) |
|
|
Size 27 |
||
|
430 l/min |
430 1) 3) |
|
|
Flow characteristic |
||
|
07 |
Progressive with linear fine control range |
M |
|
Inflected characteristic curve, linear (inflection at 40 %) |
P |
|
|
Linear |
L |
|
|
08 |
Component series 20 ... 29 (20 ... 29: unchanged installation and connection dimensions) - Size 6 |
2X |
|
Supply voltage of the control electronics |
||
|
09 |
Direct voltage 24 V |
G24 |
|
Pilot oil supply and return |
||
|
10 |
External pilot oil supply, external pilot oil return |
no code |
|
Internal pilot oil supply, external pilot oil return |
E |
|
|
Pilot oil supply internal, pilot oil return internal |
ET |
|
|
External pilot oil supply, internal pilot oil return |
T |
|
|
Electrical connection |
||
|
11 |
Without mating connector; connector DIN 43563-AM6 |
K0 |
|
Electrical interface |
||
|
12 |
Command value ±10 V |
B5 |
|
Seal material |
||
|
13 |
NBR seals |
M |
|
14 |
Further details in the plain text |
* |
|
1) |
NG27 is a high-flow version of NG25, the connection bores P, A, B, T in the main stage are designed with Ø32 mm. Deviating from the standard ISO 4401-08-08-0-05, ports P, A, B, T can be bored in the manifold with a maximum of Ø30 mm. So these valves offer higher flow values QA : QB |
|
|
2) |
QN: flow characteristic P |
|
|
3) |
QN: flow characteristic M or L |
|
For applications outside these parameters, please consult us!
general
|
Type |
4WRVE | ||||
|
Size |
10 | 16 | 25 | 27 | |
|
Component series |
2X | ||||
|
Design |
Directional spool valve, pilot-operated | ||||
|
Type of actuation |
High-response directional valve NG6 with position control for pilot control and main valve | ||||
|
Anschlussart |
For subplate mounting: Porting pattern according to ISO 4401 | ||||
|
Installation position |
Any | ||||
|
Earth |
kg |
8 | 10.4 | 18.2 | |
|
Ambient temperature range |
°C |
-20 … +50 | |||
hydraulic
|
Type |
4WRVE | ||||||
|
Size |
10 | 16 | 25 | 27 | |||
|
Maximum operating pressure |
bar |
350 | |||||
|
Maximum operating pressure |
Port T |
bar |
250 | ||||
|
Port Y |
bar |
250 | |||||
|
Port X |
bar |
250 | |||||
|
Maximum operating pressure |
Port P |
External pilot oil supply |
bar |
350 | |||
|
Port A |
bar |
350 | |||||
|
Port B |
bar |
350 | |||||
|
Maximum operating pressure |
Port P |
Internal pilot oil supply |
bar |
250 | |||
|
Port A |
bar |
250 | |||||
|
Port B |
bar |
250 | |||||
|
Nominal flow 1) |
l/min |
40 55 70 85 |
90 120 150 200 |
300 370 |
430 | ||
|
Nominal flow |
Pilot control valve |
l/min |
8 | 24 | 40 | ||
|
Maximum flow |
l/min |
170 | 450 | 900 | 1000 | ||
|
Hydraulic fluid temperature range |
°C |
-20 … +65 | |||||
|
Viscosity range |
mm²/s |
10 … 800 | |||||
|
preferably |
mm²/s |
20 … 100 | |||||
|
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 2) |
Class 18/16/13 according to ISO 4406 (c) | ||||||
|
Hysteresis |
% |
< 0.1 | |||||
|
Manufacturing tolerance |
% |
≤ 10 | |||||
|
Temperature drift |
% |
< 1 | |||||
|
Actuating time |
0 ... 100 % |
ms |
12 | 15 | 23 | ||
|
0 ... 10 % |
ms |
6 | 7 | 10 | |||
|
Actuating time |
0 ... 100 % |
Symbol E, E1-, W6-, W8- |
ms |
40 | 50 | 90 | |
| 1) | Δp = 5 bar per edge |
| 2) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
electrical
|
Type |
4WRVE | ||
|
Power supply |
Nominal voltage |
V |
24 |
|
Lower limit value |
V |
21 | |
|
Upper limit value |
V |
40 | |
|
Duty cycle |
% |
100 | |
|
Maximum power consumption |
VA |
30 | |
|
Required fuse protection |
AT |
2.5 AF | |
|
Protection class according to DIN EN 60529 |
IP65 (with mating connector mounted and locked) | ||
|
EMC (electro-magnetic compatibility) |
CE conformity according to EMC directive 2004/108/EC tested according to EN 61000-6-2 and EN 61000-6-3 | ||
|
Zero point calibration 1) |
% |
± 1 | |
| 1) | ex works |