BOSCH REXROTH
R901390313
- BOSCH REXROTH
- Material:R901390313
- Model:4WRVE16V200L-2X/G24ETK0/B5WG02M
Due to extremely high demand, please call 877-366-7226 for availability
The Bosch Rexroth 4WRVE16V200L-2X/G24ETK0/B5WG02M (R901390313) is a pilot-operated high-response directional valve characterized by its servo quality performance and integrated electronics. This particular model boasts a state-of-the-art design that includes a control spool and sleeve, ensuring precise operation and responsiveness. The valve comes with an On-Board Electronics (OBE) system featuring a position controller for both the pilot and main stage, which are calibrated at the plant to ensure optimal performance. With its main stage designed in servo quality, the 4WRVE16V200L-2X/G24ETK0/B5WG02M valve provides accurate position feedback, which is crucial for applications requiring precise control. The flow characteristics of this model are versatile, offering different options such as progressive and fine control edge (M), an inflected characteristic curve (P), and linear (L) to cater to various operational needs. This Bosch Rexroth valve is recognized for its size Component series X, which allows it to handle a maximum operating pressure of up to bar units and supports a maximum flow rate expressed in liters per minute. It also has a nominal flow rate specified in liters per minute, signifying its capacity to manage substantial flow rates while maintaining precision. The robust construction and advanced technology make this valve an ideal choice for applications demanding high levels of accuracy and reliability in controlling fluid dynamics within hydraulic systems.
Valves of type 4WRVE are pilot-operated high-response valves in servo quality.
|
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
10 |
11 |
12 |
13 |
14 |
|||
|
4 |
WRV |
E |
‒ |
2X |
/ |
G24 |
K0 |
/ |
B5 |
M |
* |
|
01 |
4 main ports |
4 |
|
02 |
High-response directional valve, pilot operated |
WRV |
|
03 |
With integrated electronics (OBE) |
E |
|
04 |
Size 10 |
10 |
|
Size 16 |
16 |
|
|
Size 25 |
25 |
|
|
Size 27 |
27 1) |
|
|
05 |
Symbols; for the possible version, see "Symbols/Circuit diagrams" |
V, V1 |
|
Rated flow (Δp = 5 bar) |
||
|
06 |
Size 10 |
|
|
40 l/min |
40 2) |
|
|
55 l/min |
55 3) |
|
|
70 l/min |
70 2) |
|
|
85 l/min |
85 3) |
|
|
Size 16 |
||
|
90 l/min |
90 2) |
|
|
120 l/min |
120 3) |
|
|
150 l/min |
150 2) |
|
|
200 l/min |
200 3) |
|
|
Size 25 |
||
|
300 l/min |
300 2) |
|
|
370 l/min |
370 3) |
|
|
Size 27 |
||
|
430 l/min |
430 1) 3) |
|
|
Flow characteristic |
||
|
07 |
Progressive with linear fine control range |
M |
|
Inflected characteristic curve, linear (inflection at 40 %) |
P |
|
|
Linear |
L |
|
|
08 |
Component series 20 ... 29 (20 ... 29: unchanged installation and connection dimensions) - Size 6 |
2X |
|
Supply voltage of the control electronics |
||
|
09 |
Direct voltage 24 V |
G24 |
|
Pilot oil supply and return |
||
|
10 |
External pilot oil supply, external pilot oil return |
no code |
|
Internal pilot oil supply, external pilot oil return |
E |
|
|
Pilot oil supply internal, pilot oil return internal |
ET |
|
|
External pilot oil supply, internal pilot oil return |
T |
|
|
Electrical connection |
||
|
11 |
Without mating connector; connector DIN 43563-AM6 |
K0 |
|
Electrical interface |
||
|
12 |
Command value ±10 V |
B5 |
|
Seal material |
||
|
13 |
NBR seals |
M |
|
14 |
Further details in the plain text |
* |
|
1) |
NG27 is a high-flow version of NG25, the connection bores P, A, B, T in the main stage are designed with Ø32 mm. Deviating from the standard ISO 4401-08-08-0-05, ports P, A, B, T can be bored in the manifold with a maximum of Ø30 mm. So these valves offer higher flow values QA : QB |
|
|
2) |
QN: flow characteristic P |
|
|
3) |
QN: flow characteristic M or L |
|
For applications outside these parameters, please consult us!
general
|
Type |
4WRVE | ||||
|
Size |
10 | 16 | 25 | 27 | |
|
Component series |
2X | ||||
|
Design |
Directional spool valve, pilot-operated | ||||
|
Type of actuation |
High-response directional valve NG6 with position control for pilot control and main valve | ||||
|
Anschlussart |
For subplate mounting: Porting pattern according to ISO 4401 | ||||
|
Installation position |
Any | ||||
|
Earth |
kg |
8 | 10.4 | 18.2 | |
|
Ambient temperature range |
°C |
-20 … +50 | |||
hydraulic
|
Type |
4WRVE | ||||||
|
Size |
10 | 16 | 25 | 27 | |||
|
Maximum operating pressure |
bar |
350 | |||||
|
Maximum operating pressure |
Port T |
bar |
250 | ||||
|
Port Y |
bar |
250 | |||||
|
Port X |
bar |
250 | |||||
|
Maximum operating pressure |
Port P |
External pilot oil supply |
bar |
350 | |||
|
Port A |
bar |
350 | |||||
|
Port B |
bar |
350 | |||||
|
Maximum operating pressure |
Port P |
Internal pilot oil supply |
bar |
250 | |||
|
Port A |
bar |
250 | |||||
|
Port B |
bar |
250 | |||||
|
Nominal flow 1) |
l/min |
40 55 70 85 |
90 120 150 200 |
300 370 |
430 | ||
|
Nominal flow |
Pilot control valve |
l/min |
8 | 24 | 40 | ||
|
Maximum flow |
l/min |
170 | 450 | 900 | 1000 | ||
|
Hydraulic fluid temperature range |
°C |
-20 … +65 | |||||
|
Viscosity range |
mm²/s |
10 … 800 | |||||
|
preferably |
mm²/s |
20 … 100 | |||||
|
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 2) |
Class 18/16/13 according to ISO 4406 (c) | ||||||
|
Hysteresis |
% |
< 0.1 | |||||
|
Manufacturing tolerance |
% |
≤ 10 | |||||
|
Temperature drift |
% |
< 1 | |||||
|
Actuating time |
0 ... 100 % |
ms |
12 | 15 | 23 | ||
|
0 ... 10 % |
ms |
6 | 7 | 10 | |||
|
Actuating time |
0 ... 100 % |
Symbol E, E1-, W6-, W8- |
ms |
40 | 50 | 90 | |
| 1) | Δp = 5 bar per edge |
| 2) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
electrical
|
Type |
4WRVE | ||
|
Power supply |
Nominal voltage |
V |
24 |
|
Lower limit value |
V |
21 | |
|
Upper limit value |
V |
40 | |
|
Duty cycle |
% |
100 | |
|
Maximum power consumption |
VA |
30 | |
|
Required fuse protection |
AT |
2.5 AF | |
|
Protection class according to DIN EN 60529 |
IP65 (with mating connector mounted and locked) | ||
|
EMC (electro-magnetic compatibility) |
CE conformity according to EMC directive 2004/108/EC tested according to EN 61000-6-2 and EN 61000-6-3 | ||
|
Zero point calibration 1) |
% |
± 1 | |
| 1) | ex works |