The Bosch Rexroth AA11VLO130LRDS/10R-NSD62N00 (R902003585) is a state-of-the-art axial piston variable pump designed with a swashplate system, tailored for high-performance hydraulic applications. This model facilitates particularly high speeds, especially when configured as an impeller pump version AVLO, showcasing its adaptability to demanding operational conditions. The pump features a through-drive capability, which allows for the mounting of additional pumps up to the same nominal size directly onto it, thus enabling complex hydraulic systems to be built without requiring additional space. It is optionally equipped with a charge pump for the nominal sizes, enhancing its utility in various hydraulic circuits by maintaining pressure within the system and providing additional operational stability. The large variety of controls available with this model ensures versatility and precision in control for different application requirements. The AA11VLO130LRDS/10R-NSD62N00 is engineered for efficiency and reliability in heavy-duty applications, where consistent hydraulic power is critical. Its robust design and advanced features make it suitable for use in mobile equipment as well as various industrial machinery systems requiring precise fluid power control. The integration of this Bosch Rexroth axial piston variable pump into hydraulic systems promises to deliver not only performance but also the adaptability needed to meet the challenges of modern hydraulic tasks.
Table of values
|
Size |
40 | 60 | 75 | 95 | 130 | 145 | 190 | 260 | 130 | 145 | 190 | 260 | |||
|
Version |
Standard | With charge pump | |||||||||||||
|
Displacement |
Vg max |
cm³ |
42 | 58.5 | 74 | 93.5 | 130 | 145 | 193 | 260 | 130 | 145 | 193 | 260 | |
|
Nominal pressure |
pnom |
bar |
350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | |
|
Maximum pressure |
pmax |
bar |
400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | |
|
Maximum speed |
at Vg max |
nnom |
rpm |
3000 1) | 2700 1) | 2550 1) | 2350 1) | 2100 1) | 2200 1) | 2100 1) | 1800 1) | 2500 2) | 2500 2) | 2500 2) | 2300 2) |
|
Flow |
at Vg max and nnom |
qV nom |
l/min |
126 | 158 | 189 | 220 | 273 | 319 | 405 | 468 | 325 | 363 | 483 | 598 |
|
Power |
at qV nom and pnom |
P |
kW |
74 | 92 | 110 | 128 | 159 | 186 | 236 | 273 | 190 | 211 | 281 | 349 |
|
Torque |
at Vg max and pnom |
M |
Nm |
234 | 326 | 412 | 521 | 724 | 808 | 1075 | 1448 | 724 | 808 | 1075 | 1448 |
|
Weight (approx.) |
m |
kg |
32 | 40 | 45 | 53 | 66 | 76 | 95 | 125 | 72 | 73 | 104 | 138 | |
| 1) | These values are valid at an absolute pressure of 1 bar in suction port S and for the optimum viscosity range νopt |
| 2) | These values are valid at an absolute pressure of 0,8 bar in suction port S and for the optimum viscosity range νopt |