The Bosch Rexroth A A10V O 45 DFR /31R-PUC61N00 (R910909913) is a high-quality all-purpose medium pressure pump designed for open circuit applications. This model features a swashplate design that contributes to its exceptional suction characteristics, ensuring efficient operation and fluid power control in various hydraulic systems. The pump's through drive capability allows for the mounting of additional pumps up to the same nominal size, making it versatile for systems requiring multiple pump solutions. With a size specification that reflects its robust performance, the A A10V O 45 DFR /31R-PUC61N00 operates with a nominal pressure of up to bar and can withstand maximum pressure peaks up to bar. Its low operating noise level enhances the working environment while its long service life and short control response times ensure reliability and responsiveness in demanding operational conditions. This Bosch Rexroth pump is equipped with drain ports that facilitate maintenance and enhance the overall serviceability of the hydraulic system. The combination of advanced engineering and high-grade materials used in its construction results in a durable pump solution that meets rigorous industrial standards. Whether it's utilized in mobile or industrial applications, this model delivers consistent performance and adaptability to meet the needs of complex hydraulic systems.
Table of values
|
Size |
18 | 28 | 45 | 71 | 88 | 100 | 140 | 45 | 71 | 100 | 140 | |||
|
Version |
Standard | High speed | ||||||||||||
|
Displacement |
Vg max |
cm³ |
18 | 28 | 45 | 71 | 88 | 100 | 140 | 45 | 71 | 100 | 140 | |
|
Nominal pressure |
pnom |
bar |
280 | 280 | 280 | 280 | 280 | 280 | 280 | 280 | 280 | 280 | 280 | |
|
Maximum pressure |
pmax |
bar |
350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | |
|
Maximum speed 1) |
at Vg max |
nnom |
rpm |
3300 | 3000 | 2600 | 2200 | 2100 | 2000 | 1800 | 3000 | 2550 | 2300 | 2050 |
|
Flow |
at Vg max and nnom |
qV nom |
l/min |
59 | 84 | 117 | 156 | 185 | 200 | 252 | 135 | 178 | 230 | 287 |
|
at Vg max and n = 1500 rpm |
qV 1500 |
l/min |
27 | 42 | 68 | 107 | 132 | 150 | 210 | 68 | 107 | 150 | 210 | |
|
Power |
at qV nom and pnom |
P |
kW |
30 | 39 | 55 | 73 | 86 | 93 | 118 | 63 | 83 | 107 | 134 |
|
at qV 1500 and pnom |
P 1500 |
kW |
12.6 | 20 | 32 | 50 | 62 | 70 | 98 | 32 | 50 | 70 | 98 | |
|
Torque |
at Vg max and pnom |
M |
Nm |
80 | 125 | 200 | 316 | 392 | 445 | 623 | 200 | 316 | 445 | 623 |
|
Weight (approx.) |
m |
kg |
12.9 | 18 | 23.5 | 35.2 | 35.2 | 49.5 | 65.4 | 23.5 | 35.2 | 49.5 | 65.4 | |
| 1) | These values are valid at an absolute pressure of 1 bar in suction port S and for the optimum viscosity range νopt |