SUN HYDRAULICS
CBAACHV
$78.53 USD
- SUN HYDRAULICS
- Material:CBAACHV
- Model:CBAA-CHV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CBAACHV (CBAACHV) is a meticulously engineered counterbalance valve designed to manage overrunning loads effectively in hydraulic systems. This valve features a check valve that permits free flow from the directional valve port to the load port, while a direct-acting, pilot-assisted relief valve modulates flow from port to port. The pilot assist at designated ports reduces the effective setting of the relief valve based on the pilot ratio, enhancing control precision under varying load conditions. The CBAACHV is set to be at least 1.3 times the maximum load-induced pressure ensuring robust performance and reliability. It offers adjustable settings, which can be decreased by turning clockwise to release the load, with a full clockwise setting being less than 350 psi (24 bar). Notably, backpressure at specific ports augments the effective relief setting in proportion to the pilot ratio and backpressure magnitude. For installation flexibility, Sun counterbalance cartridges can be directly integrated into machined cavities within an actuator housing, which bolsters protection and circuit stiffness. The model provides two check valve cracking pressures to accommodate different operational demands and prevent actuator cavitation. Moreover, it boasts positive seals between all ports ensuring leak-proof operation. This model also incorporates Sun’s floating style construction minimizing internal parts binding due to excessive installation torque or cavity/cartridge machining variations. With its comprehensive configuration options and robust design tailored for corrosive environments (model code suffixes AP and LH indicate external stainless steel or zinc-nickel plated components respectively), the CBAACHV is an optimal solution for sophisticated hydraulic applications requiring precise motion control and load handling capabilities.
The Sun Hydraulics CBAACHV (CBAACHV) is a meticulously engineered counterbalance valve designed to manage overrunning loads effectively in hydraulic systems. This valve features a check valve that permits free flow from the directional valve port to the load port, while a direct-acting, pilot-assisted relief valve modulates flow from port to port. The pilot assist at designated ports reduces the effective setting of the relief valve based on the pilot ratio, enhancing control precision under varying load conditions. The CBAACHV is set to be at least 1.3 times the maximum load-induced pressure ensuring robust performance and reliability. It offers adjustable settings, which can be decreased by turning clockwise to release the load, with a full clockwise setting being less than 350 psi (24 bar). Notably, backpressure at specific ports augments the effective relief setting in proportion to the pilot ratio and backpressure magnitude. For installation flexibility, Sun counterbalance cartridges can be directly integrated into machined cavities within an actuator housing, which bolsters protection and circuit stiffness. The model provides two check valve cracking pressures to accommodate different operational demands and prevent actuator cavitation. Moreover, it boasts positive seals between all ports ensuring leak-proof operation. This model also incorporates Sun’s floating style construction minimizing internal parts binding due to excessive installation torque or cavity/cartridge machining variations. With its comprehensive configuration options and robust design tailored for corrosive environments (model code suffixes AP and LH indicate external stainless steel or zinc-nickel plated components respectively), the CBAACHV is an optimal solution for sophisticated hydraulic applications requiring precise motion control and load handling capabilities.
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
- Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
- Restrictive valves have no relief capacity other than as a thermal relief.
- Turn adjustment clockwise to decrease setting and release load.
- Full clockwise setting is less than 200 psi (14 bar).
- Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
- Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
- Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
- Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
- This valve has positive seals between all ports.
- All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
- Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 2.5 gpm10 L/min. |
| Pilot Ratio | 3:13:1 |
| Maximum Recommended Load Pressure at Maximum Setting | 3075 psi215 bar |
| Maximum Setting | 4000 psi280 bar |
| Pilot Configuration | SealedSealed |
| Factory Pressure Settings Established at | 2 in³/min.30 cc/min. |
| Maximum Valve Leakage at Reseat | 5 drops/min.0,3 cc/min. |
| Adjustment - Number of Counterclockwise Turns to Increase Setting | 3.753.75 |
| Operating Characteristic | Ultra-restrictiveUltra-restrictive |
| Reseat | >85% of setting>85% of setting |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .40 lb0,20 kg |
| Seal kit - Cartridge | Viton: 990-011-006 |
Show FAQ