***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CBAACIV (CBAACIV) is a counterbalance valve designed to manage the control of overrunning loads in hydraulic systems. This valve features a check valve that permits free flow from the directional valve port to the load port, while a direct-acting, pilot-assisted relief valve regulates flow from port to port. The pilot assist at the designated port effectively reduces the relief valve's setting based on the pilot ratio. This model incorporates Sun Hydraulics' floating style construction, which minimizes potential internal part binding due to excessive installation torque or variations in cavity/cartridge machining. The CBAACIV is engineered for robust performance with a maximum recommended load pressure at its highest setting of 5000 psi (344.7 bar) and a flow capacity of 3.8 gpm (14.4 L/min). It offers dual check valve cracking pressures for versatility in application, ensuring optimal functionality even in scenarios where actuator cavitation might be a concern. The configuration options for this model include corrosion-resistant versions with external stainless steel components or external zinc-nickel plated components, enhancing its suitability for use in corrosive environments. Additionally, all port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable within the same frame size, providing flexibility and ease of use across different system setups. Designed with precision and reliability at its core, the CBAACIV ensures efficient operation with minimal leakage at reseat and adjustable settings that can be fine-tuned to meet specific application requirements. This makes it an essential component for various hydraulic applications where controlled motion and load handling are critical.
The Sun Hydraulics CBAACIV (CBAACIV) is a counterbalance valve designed to manage the control of overrunning loads in hydraulic systems. This valve features a check valve that permits free flow from the directional valve port to the load port, while a direct-acting, pilot-assisted relief valve regulates flow from port to port. The pilot assist at the designated port effectively reduces the relief valve's setting based on the pilot ratio. This model incorporates Sun Hydraulics' floating style construction, which minimizes potential internal part binding due to excessive installation torque or variations in cavity/cartridge machining. The CBAACIV is engineered for robust performance with a maximum recommended load pressure at its highest setting of 5000 psi (344.7 bar) and a flow capacity of 3.8 gpm (14.4 L/min). It offers dual check valve cracking pressures for versatility in application, ensuring optimal functionality even in scenarios where actuator cavitation might be a concern. The configuration options for this model include corrosion-resistant versions with external stainless steel components or external zinc-nickel plated components, enhancing its suitability for use in corrosive environments. Additionally, all port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable within the same frame size, providing flexibility and ease of use across different system setups. Designed with precision and reliability at its core, the CBAACIV ensures efficient operation with minimal leakage at reseat and adjustable settings that can be fine-tuned to meet specific application requirements. This makes it an essential component for various hydraulic applications where controlled motion and load handling are critical.
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
- Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
- Restrictive valves have no relief capacity other than as a thermal relief.
- Turn adjustment clockwise to decrease setting and release load.
- Full clockwise setting is less than 200 psi (14 bar).
- Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
- Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
- Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
- Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
- This valve has positive seals between all ports.
- All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
- Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 2.5 gpm10 L/min. |
| Pilot Ratio | 3:13:1 |
| Maximum Recommended Load Pressure at Maximum Setting | 3075 psi215 bar |
| Maximum Setting | 4000 psi280 bar |
| Pilot Configuration | SealedSealed |
| Factory Pressure Settings Established at | 2 in³/min.30 cc/min. |
| Maximum Valve Leakage at Reseat | 5 drops/min.0,3 cc/min. |
| Adjustment - Number of Counterclockwise Turns to Increase Setting | 3.753.75 |
| Operating Characteristic | Ultra-restrictiveUltra-restrictive |
| Reseat | >85% of setting>85% of setting |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .40 lb0,20 kg |
| Seal kit - Cartridge | Viton: 990-011-006 |