You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
CBBARIV


$78.53 USD
  • SUN HYDRAULICS
  • Material:CBBARIV
  • Model:CBBA-RIV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CBBARIV (CBBARIV) is a meticulously engineered counterbalance valve designed to manage the control of overrunning loads in hydraulic systems. This valve incorporates a check valve that permits free flow from the directional valve port to the load port, while its direct-acting, pilot-assisted relief valve regulates flow from port to port. The pilot assist feature at port significantly lowers the relief valve's effective setting based on the pilot ratio, enhancing operational efficiency and safety. The CBBARIV is equipped with robust features including an adjustment mechanism that allows for clockwise turning to decrease setting and release load, with a full clockwise setting of less than 5 psi or 0.3 bar. It also effectively handles backpressure at port by adding to the relief setting at a rate determined by the pilot ratio plus backpressure. Importantly, this model ensures high reseat integrity, exceeding 90% of set pressure when standard set, although lower settings may reduce reseat percentages. Designed for versatility and interchangeability within a given frame size, Sun Hydraulics' counterbalance cartridges can be directly installed into cavities machined into an actuator housing. This enhances protection and circuit stiffness. The CBBARIV model offers two check valve cracking pressures to cater to different application needs regarding actuator cavitation concerns. Moreover, this model is built using Sun's floating style construction which minimizes internal parts binding due to excessive installation torque or cavity/cartridge machining variations. With positive seals between all ports and options for corrosion resistance through external stainless steel or zinc-nickel plated components (model code suffixes AP and LH respectively), this valve promises durability and reliability in corrosive environments. With its comprehensive design and advanced functionality, the Sun Hydraulics CBBARIV counterbalance valve is an essential component for sophisticated hydraulic circuits requiring precise load control and enhanced stability.

Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.

Other names for this valve include motion control valve and over center valve.

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Restrictive valves have no relief capacity other than as a thermal relief.
  • Turn adjustment clockwise to decrease setting and release load.
  • Full clockwise setting is less than 200 psi (14 bar).
  • Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
  • This valve has positive seals between all ports.
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-11A
Series 1
Capacity 5 gpm20 L/min.
Pilot Ratio 3:13:1
Maximum Recommended Load Pressure at Maximum Setting 3075 psi215 bar
Maximum Setting 4000 psi280 bar
Factory Pressure Settings Established at 2 in³/min.30 cc/min.
Maximum Valve Leakage at Reseat 5 drops/min.0,3 cc/min.
Adjustment - Number of Counterclockwise Turns to Increase Setting 3.753.75
Operating Characteristic RestrictiveRestrictive
Reseat >85% of setting>85% of setting
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size 5/32 in.4 mm
Locknut Hex Size 9/16 in.15 mm
Locknut Torque 80 - 90 lbf in.9 - 10 Nm
Model Weight .40 lb0,20 kg
Seal kit - Cartridge Viton: 990-011-006

Show FAQ