SUN HYDRAULICS
CBBDLCN
$67.90 USD
- SUN HYDRAULICS
- Material:CBBDLCN
- Model:CBBD-LCN
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CBBDLCN (CBBDLCN) is a sophisticated counterbalance valve designed to manage overrunning loads in hydraulic systems. This valve features a check valve that allows free flow from the directional valve port to the load port, while its direct-acting, pilot-assisted relief valve controls flow from port to port. The pilot assist at port reduces the effective setting of the relief valve according to a predetermined pilot ratio, enhancing the control and stability of load movement. The CBBDLCN can be directly installed into a cavity machined into an actuator housing, which enhances protection and circuit stiffness. It is designed with two check valve cracking pressures to cater to different operational needs — using a 3 psi (0.21 bar) check unless actuator cavitation is a concern. The design incorporates positive seals between all ports ensuring robust performance and minimal leakage. This model also benefits from Sun's floating style construction which minimizes internal parts binding due to excessive installation torque or cavity/cartridge machining variations. With capabilities such as an adjustment feature allowing clockwise turns to decrease setting and release load, and backpressure at port adding effectively to the relief setting, this valve is highly adaptable for various hydraulic applications. Its maximum recommended load pressure at maximum setting stands at 5000 psi (345 bar), with factory pressure settings established at 10 in^3/min (164 cc/min). Moreover, this counterbalance valve model exhibits exceptional reseat characteristics, exceeding 90% of set pressure when standard set, although lower settings may result in reduced reseat percentages. This makes it highly reliable in maintaining control under varying pressures and flows within hydraulic systems.
The Sun Hydraulics CBBDLCN (CBBDLCN) is a sophisticated counterbalance valve designed to manage overrunning loads in hydraulic systems. This valve features a check valve that allows free flow from the directional valve port to the load port, while its direct-acting, pilot-assisted relief valve controls flow from port to port. The pilot assist at port reduces the effective setting of the relief valve according to a predetermined pilot ratio, enhancing the control and stability of load movement. The CBBDLCN can be directly installed into a cavity machined into an actuator housing, which enhances protection and circuit stiffness. It is designed with two check valve cracking pressures to cater to different operational needs — using a 3 psi (0.21 bar) check unless actuator cavitation is a concern. The design incorporates positive seals between all ports ensuring robust performance and minimal leakage. This model also benefits from Sun's floating style construction which minimizes internal parts binding due to excessive installation torque or cavity/cartridge machining variations. With capabilities such as an adjustment feature allowing clockwise turns to decrease setting and release load, and backpressure at port adding effectively to the relief setting, this valve is highly adaptable for various hydraulic applications. Its maximum recommended load pressure at maximum setting stands at 5000 psi (345 bar), with factory pressure settings established at 10 in^3/min (164 cc/min). Moreover, this counterbalance valve model exhibits exceptional reseat characteristics, exceeding 90% of set pressure when standard set, although lower settings may result in reduced reseat percentages. This makes it highly reliable in maintaining control under varying pressures and flows within hydraulic systems.
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
- Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
- Turn adjustment clockwise to decrease setting and release load.
- Full clockwise setting is less than 200 psi (14 bar).
- Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
- Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
- Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
- Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
- This valve has positive seals between all ports.
- All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
- Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 10 gpm40 L/min. |
| Pilot Ratio | 4.5:14.5:1 |
| Maximum Recommended Load Pressure at Maximum Setting | 3850 psi270 bar |
| Maximum Setting | 5000 psi350 bar |
| Factory Pressure Settings Established at | 2 in³/min.30 cc/min. |
| Maximum Valve Leakage at Reseat | 5 drops/min.0,3 cc/min. |
| Adjustment - Number of Counterclockwise Turns to Increase Setting | 3.753.75 |
| Operating Characteristic | Semi-restrictiveSemi-restrictive |
| Reseat | >85% of setting>85% of setting |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .40 lb0,20 kg |