***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CBBHCKV (CBBHCKV) is a meticulously engineered counterbalance valve designed to manage overrunning loads effectively in various hydraulic applications. This valve features a check valve that permits free flow from the directional valve port to the load port, while a direct-acting, pilot-assisted relief valve regulates flow from port to port. The pilot assist at the designated port significantly lowers the effective setting of the relief valve according to a predetermined pilot ratio, enhancing overall operational efficiency and stability. Among its capabilities, the CBBHCKV ensures that backpressure at one port contributes to the effective relief setting in conjunction with the pilot ratio, optimizing performance under varying pressures. The design includes an adjustment mechanism where turning clockwise decreases the setting and releases load, with a full clockwise setting maintaining pressure below specific thresholds. Notably, this model does not possess positive seals on its pilot section and may exhibit minimal leakage under certain conditions, which should be considered during system integration especially in masterslave circuits or when conducting leak tests of valve-cylinder assemblies. The CBBHCKV also stands out due to its construction that incorporates Sun's floating style design aimed at minimizing internal parts binding caused by excessive installation torque or cavity-cartridge machining variations. This feature ensures reliable operation and longevity even under demanding conditions. Furthermore, Sun Hydraulics offers this model with two different check valve cracking pressures to accommodate varying actuator demands and prevent potential cavitation issues. This counterbalance valve is ideal for installations directly into actuator housings due to its compact cartridge design which enhances protection and circuit stiffness. Its interchangeable nature across all port counterbalance, load control, and pilot-to-open check cartridges for a given frame size adds versatility and ease of use in system design adjustments or replacements.

Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.

Other names for this valve include motion control valve and over center valve.

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Restrictive valves have no relief capacity other than as a thermal relief.
  • Turn adjustment clockwise to decrease setting and release load.
  • Full clockwise setting is less than 200 psi (14 bar).
  • Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • This valve does not have positive seals on the pilot section and will pass between 2 and 20 in³/min./1000 psi (0,03 and 0,3 L/min./70 bar) between port 2 and port 3, depending on load pressure. This is a consideration in master-slave circuits and in the leak testing of valve-cylinder assemblies.
  • Lower pilot ratios (pilot gain) promote machine stability.
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-11A
Series 1
Capacity 5 gpm20 L/min.
Pilot Ratio 10:110:1
Maximum Recommended Load Pressure at Maximum Setting 3850 psi270 bar
Maximum Setting 5000 psi350 bar
Pilot Configuration StandardStandard
Factory Pressure Settings Established at 2 in³/min.30 cc/min.
Maximum Valve Leakage at Reseat 5 drops/min.0,3 cc/min.
Adjustment - Number of Counterclockwise Turns to Increase Setting 3.753.75
Operating Characteristic StandardStandard
Reseat >85% of setting>85% of setting
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size 5/32 in.4 mm
Locknut Hex Size 9/16 in.15 mm
Locknut Torque 80 - 90 lbf in.9 - 10 Nm
Model Weight .40 lb0,20 kg
Seal kit - Cartridge Viton: 990-011-006