You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
CBBHLDN


$74.26 USD
  • SUN HYDRAULICS
  • Material:CBBHLDN
  • Model:CBBH-LDN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CBBHLDN (CBBHLDN) is a sophisticated counterbalance valve designed to manage the control of overrunning loads in hydraulic systems. It features a check valve that permits free flow from the directional valve port to the load port, alongside a direct-acting, pilot-assisted relief valve that regulates flow from port to port. The pilot assist at the designated port effectively reduces the relief valve setting based on the pilot ratio, enhancing operational efficiency and stability. This model is engineered to ensure that settings are at least 1.3 times the maximum load-induced pressure to maintain reliable operation under varying pressures. The adjustment mechanism is user-friendly, allowing settings to be decreased by turning clockwise, which helps in releasing the load smoothly. Notably, backpressure at specific ports incrementally adds to the effective relief setting, factoring in both pilot ratio and backpressure magnitude. The CBBHLDN does not use positive seals on its pilot section and may exhibit a leakage of 5-10 in³/min at 1000 psi between critical ports, which should be considered when designing master-slave circuits or during leak testing of valve-cylinder assemblies. Furthermore, Sun Hydraulics has designed this counterbalance cartridge for direct installation into actuator housings, which enhances protection and circuit stiffness. The device supports various configurations with a standard factory pressure setting established at specific flows and pressures. Its robust design incorporates Sun's floating style construction which minimizes internal parts binding due to installation torque or cavity/cartridge machining variances. This makes it an adaptable solution for diverse hydraulic applications requiring precise motion control and load handling capabilities.

Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.

Other names for this valve include motion control valve and over center valve.

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Restrictive valves have no relief capacity other than as a thermal relief.
  • Turn adjustment clockwise to decrease setting and release load.
  • Full clockwise setting is less than 200 psi (14 bar).
  • Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • This valve does not have positive seals on the pilot section and will pass between 2 and 20 in³/min./1000 psi (0,03 and 0,3 L/min./70 bar) between port 2 and port 3, depending on load pressure. This is a consideration in master-slave circuits and in the leak testing of valve-cylinder assemblies.
  • Lower pilot ratios (pilot gain) promote machine stability.
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-11A
Series 1
Capacity 5 gpm20 L/min.
Pilot Ratio 10:110:1
Maximum Recommended Load Pressure at Maximum Setting 3850 psi270 bar
Maximum Setting 5000 psi350 bar
Pilot Configuration StandardStandard
Factory Pressure Settings Established at 2 in³/min.30 cc/min.
Maximum Valve Leakage at Reseat 5 drops/min.0,3 cc/min.
Adjustment - Number of Counterclockwise Turns to Increase Setting 3.753.75
Operating Characteristic StandardStandard
Reseat >85% of setting>85% of setting
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size 5/32 in.4 mm
Locknut Hex Size 9/16 in.15 mm
Locknut Torque 80 - 90 lbf in.9 - 10 Nm
Model Weight .40 lb0,20 kg
Seal kit - Cartridge Viton: 990-011-006

Show FAQ