***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CBCAXPN (CBCAXPN) is a fixed-setting, 3-port counterbalance valve with a pilot assist function designed to control overrunning loads effectively. These valves are preset to a nominal value and operate by allowing free flow from the directional valve port 2 to the load port 1, while a direct-acting, pilot-assisted relief valve manages flow from port 1 to port 2. The pilot assist at port 3 helps lower the effective setting of the relief valve at a rate determined by the pilot ratio. This model is particularly useful in applications where matched valve settings are not critical, such as protecting cylinder seals in outrigger circuits against damage due to thermal expansion. The CBCAXPN features a T11A cavity and operates with a maximum capacity of 15 gpm (60 L/min). Its factory pressure settings are established at an efficient leakage rate of only 2 in³/min (30 cc/min), with maximum valve leakage at reseat maintained at less than 5 drops/min (0.3 cc/min). The check cracking pressure stands at an accessible 25 psi (1.7 bar), ensuring reliability and performance consistency. This model is equipped with Viton seals suitable for systems using phosphate ester fluids; however, exposure to petroleum-based fluids can damage these seals. The construction incorporates Sun's floating style to minimize internal parts binding due to installation torque or cavity/cartridge machining variations. Additionally, backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure, enhancing its operational flexibility. Overall, the Sun Hydraulics CBCAXPN offers robust performance for specific hydraulic circuit applications where fixed settings suffice and high precision is not mandatory.

Fixed-setting, 3-port counterbalance valves with pilot assist function similarly to the adjustable versions except the fixed setting is pre-set to a nominal value. These fixed-setting valves are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.

Other names for this valve include motion control valve and over center valve.

  • The maximum recommended load pressure for the N range is 2200 psi (150 bar). The highest cracking pressure for the N range will be less than 3500 psi (245 bar).
  • The maximum recommended load pressure for the P range is 1700 psi (120 bar). The highest cracking pressure for the P range will be less than 2680 psi (185 bar).
  • Note: The pressures listed under RANGE are approximate, mean values and should not be used for inspection purposes.
  • Note: The percentage difference between the cracking and reseat values for the fixed and adjustable versions of this valve are identical. However, the cracking point for the adjustable control can be set via the adjustment mechanism to within +/- 50 psi (3,5 bar) of the specified value. In the case of the fixed-setting version, the setting tolerance can only be maintained within a several hundred psi span, depending on the range. The maximum recommended load pressure for any given range is the minimum possible setting divided by 1.3.
  • Fixed-setting counterbalance valves offer a shorter cartridge extension than the adjustable version.
  • Fixed-setting counterbalance valves can be used to protect cylinder seals in outrigger circuits from damage due to thermal expansion, however, they probably should not be applied in circuits in which a matched valve setting may be required such as dual cylinder applications.
  • This valve does not have positive seals on the pilot section and will pass up to 3 in³/min.@1000 psi (45 ml/min.@70 bar ) between port 2 and port 3. This is a consideration in master-slave circuits and in the leak testing of valve-cylinder assemblies.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-11A
Series 1
Capacity 15 gpm60 L/min.
Pilot Ratio 3:13:1
Factory Pressure Settings Established at 2 in³/min.30 cc/min.
Maximum Valve Leakage at Reseat 5 drops/min.0,3 cc/min.
Check Cracking Pressure 25 psi1,7 bar
Operating Characteristic StandardStandard
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Model Weight .35 lb0,15 kg
Seal kit - Cartridge Viton: 990-011-006