SUN HYDRAULICS
CBCYXNV
$70.19 USD
- SUN HYDRAULICS
- Material:CBCYXNV
- Model:CBCY-XNV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CBCYXNV (CBCYXNV) is a fixed-setting, 3-port counterbalance valve designed with a pilot assist feature. This valve model is engineered to control overrunning loads effectively, ensuring operational stability and safety. The CBCYXNV allows free flow from the directional valve port 2 to the load port 1 while controlling the flow from port 1 to port 2 through a direct-acting, pilot-assisted relief valve. The addition of pilot assist at port 3 modifies the effective setting of the relief valve based on the pilot ratio, enhancing its functionality in various hydraulic applications. This model is particularly noted for its robust performance specifications including a maximum recommended load pressure for different ranges—2200 psi for the N range and 1700 psi for the P range. It features a cracking pressure less than 3500 psi for N range and less than 2680 psi for P range, providing flexibility across different operational settings. The CBCYXNV incorporates Sun Hydraulics' floating style construction which minimizes internal parts binding due to installation torque or cavity/cartridge machining variations, ensuring reliable performance. The CBCYXNV's compact design offers advantages such as shorter cartridge extension compared to adjustable versions and is suitable for applications where matched valve settings are not critical, such as protecting cylinder seals in outrigger circuits from thermal expansion damage. It also accommodates up to 40 in³/min at 1000 psi between ports 2 and 3, making it viable in master-slave circuits or leak testing of valve/cylinder assemblies. This model’s interchangeability with other Sun cartridge valves of the same frame size simplifies integration into existing systems. With its preset factory settings established at specific pressures and flows, this counterbalance valve ensures consistent operation without requiring field adjustments.
The Sun Hydraulics CBCYXNV (CBCYXNV) is a fixed-setting, 3-port counterbalance valve designed with a pilot assist feature. This valve model is engineered to control overrunning loads effectively, ensuring operational stability and safety. The CBCYXNV allows free flow from the directional valve port 2 to the load port 1 while controlling the flow from port 1 to port 2 through a direct-acting, pilot-assisted relief valve. The addition of pilot assist at port 3 modifies the effective setting of the relief valve based on the pilot ratio, enhancing its functionality in various hydraulic applications. This model is particularly noted for its robust performance specifications including a maximum recommended load pressure for different ranges—2200 psi for the N range and 1700 psi for the P range. It features a cracking pressure less than 3500 psi for N range and less than 2680 psi for P range, providing flexibility across different operational settings. The CBCYXNV incorporates Sun Hydraulics' floating style construction which minimizes internal parts binding due to installation torque or cavity/cartridge machining variations, ensuring reliable performance. The CBCYXNV's compact design offers advantages such as shorter cartridge extension compared to adjustable versions and is suitable for applications where matched valve settings are not critical, such as protecting cylinder seals in outrigger circuits from thermal expansion damage. It also accommodates up to 40 in³/min at 1000 psi between ports 2 and 3, making it viable in master-slave circuits or leak testing of valve/cylinder assemblies. This model’s interchangeability with other Sun cartridge valves of the same frame size simplifies integration into existing systems. With its preset factory settings established at specific pressures and flows, this counterbalance valve ensures consistent operation without requiring field adjustments.
Fixed-setting, 3-port counterbalance valves with pilot assist function similarly to the adjustable versions except the fixed setting is pre-set to a nominal value. These fixed-setting valves are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
- The maximum recommended load pressure for the N range is 2200 psi (150 bar). The highest cracking pressure for the N range will be less than 3500 psi (245 bar).
- The maximum recommended load pressure for the P range is 1700 psi (120 bar). The highest cracking pressure for the P range will be less than 2680 psi (185 bar).
- Note: The pressures listed under RANGE are approximate, mean values and should not be used for inspection purposes.
- Note: The percentage difference between the cracking and reseat values for the fixed and adjustable versions of this valve are identical. However, the cracking point for the adjustable control can be set via the adjustment mechanism to within +/- 50 psi (3,5 bar) of the specified value. In the case of the fixed-setting version, the setting tolerance can only be maintained within a several hundred psi span, depending on the range. The maximum recommended load pressure for any given range is the minimum possible setting divided by 1.3.
- Fixed-setting counterbalance valves offer a shorter cartridge extension than the adjustable version.
- Fixed-setting counterbalance valves can be used to protect cylinder seals in outrigger circuits from damage due to thermal expansion, however, they probably should not be applied in circuits in which a matched valve setting may be required such as dual cylinder applications.
- This valve uses orifices to lower the pilot ratio and therefore will pass up to 40 in³/min./1000 psi (0,7 L/min./70 bar) between port 2 and port 3. This is a consideration in master-slave circuits and in the leak testing of valve-cylinder assemblies.
- Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
- All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 15 gpm60 L/min. |
| Pilot Ratio | 2:12:1 |
| Factory Pressure Settings Established at | 2 in³/min.30 cc/min. |
| Maximum Valve Leakage at Reseat | 5 drops/min.0,3 cc/min. |
| Check Cracking Pressure | 25 psi1,7 bar |
| Operating Characteristic | StandardStandard |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Model Weight | .35 lb0,15 kg |
| Seal kit - Cartridge | Viton: 990-011-006 |
Show FAQ