You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
CBDARHV


$116.26 USD
  • SUN HYDRAULICS
  • Material:CBDARHV
  • Model:CBDA-RHV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CBDARHV (CBDARHV) is a counterbalance valve with pilot assist designed to control an overrunning load effectively. This valve features a check valve that permits free flow from the directional valve port 2 to the load port 1, while a direct-acting, pilot-assisted relief valve manages flow from port 1 to port 2. The pilot assist at port 3 reduces the effective setting of the relief valve based on the pilot ratio. This product is ideal for applications requiring precise motion control, such as in hydraulic systems where load stabilization is critical. The CBDARHV model ensures reliability and performance with a maximum setting of 4000 psi (280 bar) and a capacity of up to 7.5 gpm (30 L/min). The valve's design incorporates Sun’s floating style construction which minimizes potential internal parts binding due to installation torque or cavity/cartridge machining variations, ensuring consistent operation and longevity. Additionally, it offers two check valve cracking pressures to accommodate different application needs, enhancing its versatility. For maintenance and adjustments, this model includes features that allow easy setting changes directly at the installation site. The adjustment screw facilitates manual setting changes with precision, while its robust build ensures consistent performance under varying operational conditions. Importantly, the CBDARHV maintains tight seals between all ports to prevent leakage and ensure efficient operation. Overall, the Sun Hydraulics CBDARHV counterbalance valve is an essential component for hydraulic systems requiring robust load control and efficient operation, offering ease of integration and maintenance in various industrial applications.

Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.

Other names for this valve include motion control valve and over center valve.

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Restrictive valves have no relief capacity other than as a thermal relief.
  • Turn adjustment clockwise to decrease setting and release load.
  • Full clockwise setting is less than 200 psi (14 bar).
  • Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
  • This valve has positive seals between all ports.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-2A
Series 2
Capacity 7.5 gpm30 L/min.
Pilot Ratio 3:13:1
Maximum Recommended Load Pressure at Maximum Setting 3075 psi215 bar
Maximum Setting 4000 psi280 bar
Factory Pressure Settings Established at 2 in³/min.30 cc/min.
Maximum Valve Leakage at Reseat 5 drops/min.0,3 cc/min.
Adjustment - Number of Counterclockwise Turns to Increase Setting 3.753.75
Operating Characteristic RestrictiveRestrictive
Reseat >85% of setting>85% of setting
Valve Hex Size 1 1/8 in.28,6 mm
Valve Installation Torque 45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size 5/32 in.4 mm
Locknut Hex Size 9/16 in.15 mm
Locknut Torque 80 - 90 lbf in.9 - 10 Nm
Model Weight .60 lb0,30 kg
Seal kit - Cartridge Viton: 990-202-006

Show FAQ