***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CBDCLHV (CBDCLHV) is a meticulously engineered counterbalance valve designed for controlling overrunning loads in hydraulic systems. This valve features a check valve that permits free flow from the directional valve port 2 to load port 1, while a direct-acting, pilot-assisted relief valve manages flow from port 1 to port 2. The pilot assist at port 3 effectively reduces the relief valve setting according to a predetermined pilot ratio, enhancing the operational efficiency and response of the system. The CBDCLHV is equipped with a series of features aimed at robust performance and reliability. It is designed to be set at least 1.3 times the maximum load-induced pressure, with an adjustment mechanism that allows operators to decrease settings and release loads by turning clockwise. The full clockwise setting ensures minimal pressure loss, less than 200 psi (14 bar). Additionally, backpressure at port 2 increases the effective relief setting in proportion to the pilot ratio and backpressure amount. For installation flexibility and circuit protection, Sun counterbalance cartridges can be directly installed into machined cavities within actuator housings. This model also supports two check valve cracking pressures to accommodate different application needs regarding actuator cavitation. Positive seals between all ports prevent leakage and cross-contamination between channels. Moreover, this model incorporates Sun's floating style construction which minimizes internal parts binding due to excessive installation torque or variations in cavity/cartridge machining—ensuring consistent performance even under varying installation conditions. The CBDCLHV is capable of handling up to 20 gpm (80 L/min) with a maximum setting of 4000 psi (280 bar), making it suitable for a wide range of demanding applications where precise load control is critical.

Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.

Other names for this valve include motion control valve and over center valve.

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Turn adjustment clockwise to decrease setting and release load.
  • Full clockwise setting is less than 200 psi (14 bar).
  • Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
  • This valve has positive seals between all ports.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-2A
Series 2
Capacity 20 gpm80 L/min.
Pilot Ratio 3:13:1
Maximum Recommended Load Pressure at Maximum Setting 3075 psi215 bar
Maximum Setting 4000 psi280 bar
Factory Pressure Settings Established at 2 in³/min.30 cc/min.
Maximum Valve Leakage at Reseat 5 drops/min.0,3 cc/min.
Adjustment - Number of Counterclockwise Turns to Increase Setting 3.753.75
Operating Characteristic Semi-restrictiveSemi-restrictive
Reseat >85% of setting>85% of setting
Valve Hex Size 1 1/8 in.28,6 mm
Valve Installation Torque 45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size 5/32 in.4 mm
Locknut Hex Size 9/16 in.15 mm
Locknut Torque 80 - 90 lbf in.9 - 10 Nm
Model Weight .60 lb0,30 kg
Seal kit - Cartridge Viton: 990-202-006

Show FAQ