SUN HYDRAULICS
CBDCRBV
$119.24 USD
- SUN HYDRAULICS
- Material:CBDCRBV
- Model:CBDC-RBV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CBDCRBV (CBDCRBV) is a sophisticated counterbalance valve designed to manage overrunning loads effectively in hydraulic systems. This valve features a check valve that permits free flow from the directional valve port 2 to the load port 1, while a direct-acting, pilot-assisted relief valve regulates flow from port 1 to port 2. The addition of pilot assist at port 3 reduces the effective setting of the relief valve in proportion to the pilot ratio, enhancing control and stability. Key specifications include a maximum capacity of 20 gpm (80 L/min), with a pilot ratio of 3:1 and a maximum setting pressure of 4000 psi (280 bar). The factory pressure settings are established at a flow rate of 2 in³/min (30 cc/min), ensuring precise and reliable operation. The valve also features minimal leakage at reseat, capped at 5 drops/min (0.3 cc/min), maintaining system integrity and reducing fluid loss. Designed for versatility, Sun's counterbalance cartridges can be directly installed into cavities machined in an actuator housing, which helps protect the system and enhances circuit stiffness. This model incorporates Sun’s floating style construction which minimizes internal parts binding due to excessive installation torque or cavity/cartridge machining variations. Additionally, all three-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable for given frame sizes, offering flexibility across different applications. The CBDCRBV is equipped with positive seals between all ports and offers two check valve cracking pressures to cater to different operational needs—25 psi (1.7 bar) is standard unless actuator cavitation is a concern. This robust design ensures that the CBDCRBV operates reliably under various conditions, making it an essential component for enhancing hydraulic system performance.
The Sun Hydraulics CBDCRBV (CBDCRBV) is a sophisticated counterbalance valve designed to manage overrunning loads effectively in hydraulic systems. This valve features a check valve that permits free flow from the directional valve port 2 to the load port 1, while a direct-acting, pilot-assisted relief valve regulates flow from port 1 to port 2. The addition of pilot assist at port 3 reduces the effective setting of the relief valve in proportion to the pilot ratio, enhancing control and stability. Key specifications include a maximum capacity of 20 gpm (80 L/min), with a pilot ratio of 3:1 and a maximum setting pressure of 4000 psi (280 bar). The factory pressure settings are established at a flow rate of 2 in³/min (30 cc/min), ensuring precise and reliable operation. The valve also features minimal leakage at reseat, capped at 5 drops/min (0.3 cc/min), maintaining system integrity and reducing fluid loss. Designed for versatility, Sun's counterbalance cartridges can be directly installed into cavities machined in an actuator housing, which helps protect the system and enhances circuit stiffness. This model incorporates Sun’s floating style construction which minimizes internal parts binding due to excessive installation torque or cavity/cartridge machining variations. Additionally, all three-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable for given frame sizes, offering flexibility across different applications. The CBDCRBV is equipped with positive seals between all ports and offers two check valve cracking pressures to cater to different operational needs—25 psi (1.7 bar) is standard unless actuator cavitation is a concern. This robust design ensures that the CBDCRBV operates reliably under various conditions, making it an essential component for enhancing hydraulic system performance.
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
- Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
- Turn adjustment clockwise to decrease setting and release load.
- Full clockwise setting is less than 200 psi (14 bar).
- Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
- Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
- Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
- Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
- This valve has positive seals between all ports.
- All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-2A |
| Series | 2 |
| Capacity | 20 gpm80 L/min. |
| Pilot Ratio | 3:13:1 |
| Maximum Recommended Load Pressure at Maximum Setting | 3075 psi215 bar |
| Maximum Setting | 4000 psi280 bar |
| Factory Pressure Settings Established at | 2 in³/min.30 cc/min. |
| Maximum Valve Leakage at Reseat | 5 drops/min.0,3 cc/min. |
| Adjustment - Number of Counterclockwise Turns to Increase Setting | 3.753.75 |
| Operating Characteristic | Semi-restrictiveSemi-restrictive |
| Reseat | >85% of setting>85% of setting |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .60 lb0,30 kg |
| Seal kit - Cartridge | Viton: 990-202-006 |
Show FAQ