SUN HYDRAULICS
CBDLRCN


$114.87 USD
  • SUN HYDRAULICS
  • Material:CBDLRCN
  • Model:CBDL-RCN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CBDLRCN (CBDLRCN) is a counterbalance valve with pilot assist, designed to control overrunning loads effectively in hydraulic systems. This model features a check valve that permits free flow from the directional valve port 2 to the load port 1, while a direct-acting, pilot-assisted relief valve manages the flow from port 1 to port 2. The pilot assist at port 3 reduces the relief valve's effective setting at a rate determined by the pilot ratio, enhancing control and stability in various applications. With a capacity of handling up to 20 gpm (80 L/min) and a maximum setting of 5000 psi (350 bar), the CBDLRCN is robust enough for demanding applications. The valve's design includes positive seals between all ports and incorporates Sun's floating style construction, which minimizes internal parts binding due to installation torque or machining variations. This model offers two check valve cracking pressures, providing flexibility based on specific application needs. The CBDLRCN is designed for easy integration directly into machined cavities within actuator housings, offering added protection and circuit stiffness. It also features interchangeable cartridges for different frame sizes within its series, ensuring versatility across various system configurations. This model’s comprehensive design and robust construction make it suitable for use in advanced hydraulic systems requiring precise load control and operational reliability.

Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.

Other names for this valve include motion control valve and over center valve.

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Turn adjustment clockwise to decrease setting and release load.
  • Full clockwise setting is less than 200 psi (14 bar).
  • Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
  • This valve has positive seals between all ports.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-2A
Series 2
Capacity 20 gpm80 L/min.
Pilot Ratio 2.3:12.3:1
Maximum Recommended Load Pressure at Maximum Setting 3850 psi270 bar
Maximum Setting 5000 psi350 bar
Factory Pressure Settings Established at 2 in³/min.30 cc/min.
Maximum Valve Leakage at Reseat 5 drops/min.0,3 cc/min.
Adjustment - Number of Counterclockwise Turns to Increase Setting 3.753.75
Operating Characteristic Semi-restrictiveSemi-restrictive
Reseat >85% of setting>85% of setting
Valve Hex Size 1 1/8 in.28,6 mm
Valve Installation Torque 45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size 5/32 in.4 mm
Locknut Hex Size 9/16 in.15 mm
Locknut Torque 80 - 90 lbf in.9 - 10 Nm
Model Weight .60 lb0,30 kg
Seal kit - Cartridge Viton: 990-202-006