***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CBEHRDV (CBEHRDV) is a sophisticated counterbalance valve designed for controlling overrunning loads in hydraulic systems. It features a check valve that allows free flow from the directional valve port 2 to the load port 1, while a direct-acting, pilot-assisted relief valve manages flow from port 1 to port 2. The pilot assist at port 3 reduces the effective setting of the relief valve according to the pilot ratio, enhancing control and stability in various applications. This model is engineered to be set at least 1.3 times the maximum load-induced pressure to ensure reliable operation under varying conditions. The adjustment mechanism is straightforward; turning it clockwise decreases the setting and releases the load, with a full clockwise setting being less than 200 psi (14 bar). Additionally, backpressure at port 2 increases the effective relief setting, factoring in both the pilot ratio and backpressure. The CBEHRDV can be directly installed into an actuator housing cavity, which not only protects it but also improves stiffness within the circuit. It offers two check valve cracking pressures to accommodate different operational needs, with options for either a standard or lower pressure setting based on specific system requirements. This counterbalance valve does not have positive seals on its pilot section and may allow a small pass-through of up to 2 in³/min at 1000 psi (32 cc/min at 70 bar) between port 2 and port 3. This feature needs consideration in master-slave circuits and when conducting leak tests of valve/cylinder assemblies. Constructed with Sun's floating style design, this model minimizes potential internal parts binding caused by excessive installation torque or variations in cavity/cartridge machining. This ensures consistent performance and reliability across various hydraulic applications where precise motion control is critical.
The Sun Hydraulics CBEHRDV (CBEHRDV) is a sophisticated counterbalance valve designed for controlling overrunning loads in hydraulic systems. It features a check valve that allows free flow from the directional valve port 2 to the load port 1, while a direct-acting, pilot-assisted relief valve manages flow from port 1 to port 2. The pilot assist at port 3 reduces the effective setting of the relief valve according to the pilot ratio, enhancing control and stability in various applications. This model is engineered to be set at least 1.3 times the maximum load-induced pressure to ensure reliable operation under varying conditions. The adjustment mechanism is straightforward; turning it clockwise decreases the setting and releases the load, with a full clockwise setting being less than 200 psi (14 bar). Additionally, backpressure at port 2 increases the effective relief setting, factoring in both the pilot ratio and backpressure. The CBEHRDV can be directly installed into an actuator housing cavity, which not only protects it but also improves stiffness within the circuit. It offers two check valve cracking pressures to accommodate different operational needs, with options for either a standard or lower pressure setting based on specific system requirements. This counterbalance valve does not have positive seals on its pilot section and may allow a small pass-through of up to 2 in³/min at 1000 psi (32 cc/min at 70 bar) between port 2 and port 3. This feature needs consideration in master-slave circuits and when conducting leak tests of valve/cylinder assemblies. Constructed with Sun's floating style design, this model minimizes potential internal parts binding caused by excessive installation torque or variations in cavity/cartridge machining. This ensures consistent performance and reliability across various hydraulic applications where precise motion control is critical.
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
- Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
- Turn adjustment clockwise to decrease setting and release load.
- Full clockwise setting is less than 200 psi (14 bar).
- Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
- Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
- Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
- Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
- This valve does not have positive seals on the pilot section and will pass up to 2 in³/min.@1000 psi (32 cc/min.@70 bar ) between port 2 and port 3. This is a consideration in master-slave circuits and in the leak testing of valve-cylinder assemblies.
- All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-2A |
| Series | 2 |
| Capacity | 30 gpm120 L/min. |
| Pilot Ratio | 10:110:1 |
| Maximum Recommended Load Pressure at Maximum Setting | 3850 psi270 bar |
| Maximum Setting | 5000 psi350 bar |
| Factory Pressure Settings Established at | 2 in³/min.30 cc/min. |
| Maximum Valve Leakage at Reseat | 5 drops/min.0,3 cc/min. |
| Adjustment - Number of Counterclockwise Turns to Increase Setting | 3.753.75 |
| Operating Characteristic | StandardStandard |
| Reseat | >85% of setting>85% of setting |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .60 lb0,30 kg |
| Seal kit - Cartridge | Viton: 990-202-006 |