***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CBEIRBV (CBEIRBV) is a sophisticated counterbalance valve designed for controlling overrunning loads efficiently in various hydraulic systems. This model features a check valve that permits free flow from port 2 to port 1, alongside a direct-acting, pilot-assisted relief valve that manages flow from port 1 to port 2. The incorporation of pilot assist at port 3 effectively reduces the relief valve setting based on the pilot ratio, enhancing control precision under varying load conditions. The CBEIRBV is engineered to be set at least 1.3 times the maximum load-induced pressure to ensure reliability and safety. Users can adjust the setting by turning the adjustment clockwise, which decreases the setting and releases the load, with a full clockwise setting being less than 200 psi (14 bar). Notably, backpressure at port 2 influences the effective relief setting in proportion to the pilot ratio and backpressure amount. This model showcases exceptional design considerations such as Sun's floating style construction which minimizes internal parts binding due to installation torque or cavity/cartridge machining variations. It also offers versatility with two available check valve cracking pressures—25 psi (1.7 bar) typically used unless actuator cavitation is a concern. The CBEIRBV has been meticulously tested for leakage and performance consistency, ensuring less than 5 drops/min (0.3 cc/min) leakage at reseat conditions which exceed 85% of set pressure. This makes it an ideal choice for applications requiring precise motion control such as in material handling equipment, mobile hydraulics, and industrial machinery where smooth operation and stability are critical.

Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.

Other names for this valve include motion control valve and over center valve.

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Turn adjustment clockwise to decrease setting and release load.
  • Full clockwise setting is less than 200 psi (14 bar).
  • Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
  • This valve does not have positive seals on the pilot section and will pass up to 2 in³/min.@1000 psi (32 cc/min.@70 bar ) between port 2 and port 3. This is a consideration in master-slave circuits and in the leak testing of valve-cylinder assemblies.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-2A
Series 2
Capacity 30 gpm120 L/min.
Pilot Ratio 6.5:16.5:1
Maximum Recommended Load Pressure at Maximum Setting 3850 psi270 bar
Maximum Setting 5000 psi350 bar
Factory Pressure Settings Established at 2 in³/min.30 cc/min.
Maximum Valve Leakage at Reseat 5 drops/min.0,3 cc/min.
Operating Characteristic StandardStandard
Reseat >85% of setting>85% of setting
Valve Hex Size 1 1/8 in.28,6 mm
Valve Installation Torque 45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size 5/32 in.4 mm
Locknut Hex Size 9/16 in.15 mm
Locknut Torque 80 - 90 lbf in.9 - 10 Nm
Model Weight .60 lb0,30 kg
Seal kit - Cartridge Viton: 990-202-006