You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
CBEJLHV


$110.80 USD
  • SUN HYDRAULICS
  • Material:CBEJLHV
  • Model:CBEJ-LHV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CBEJLHV (CBEJLHV) is a sophisticated counterbalance valve designed to manage overrunning loads effectively in hydraulic systems. This model features a check valve that permits free flow from port 2 to port 1 and a direct-acting, pilot-assisted relief valve that controls flow from port 1 to port 2. The pilot assist at port 3 significantly reduces the effective setting of the relief valve in accordance with the pilot ratio. The CBEJLHV is engineered to be set at least 1.3 times the maximum load-induced pressure, ensuring robust performance under varying pressures up to a maximum setting of 4000 psi (280 bar). It incorporates an adjustment mechanism where turning the adjustment clockwise decreases the setting and releases the load, with full clockwise settings dropping below 200 psi (14 bar). Additionally, backpressure at port 2 influences the effective relief setting based on a formula that includes the pilot ratio. This model also boasts Sun's floating style construction which minimizes internal parts binding – a common issue due to installation torque or cavity/cartridge machining variations. The valve is designed for easy integration directly into an actuator housing, enhancing protection and circuit stiffness. For applications sensitive to actuator cavitation, two check valve cracking pressures are available, with a standard option of 25 psi (1.7 bar). Moreover, this model can handle up to 30 gpm (120 L/min) and features standard factory pressure settings established at significant leak rates for rigorous testing scenarios. In summary, Sun Hydraulics' CBEJLHV offers robust control for hydraulic systems dealing with overrunning loads through advanced design features that accommodate various operational demands while maintaining high reliability and performance stability.

Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Turn adjustment clockwise to decrease setting and release load.
  • Full clockwise setting is less than 200 psi (14 bar).
  • Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
  • This valve does not have positive seals on the pilot section and will pass up to 2 in³/min.@1000 psi (32 cc/min.@70 bar ) between port 2 and port 3. This is a consideration in master-slave circuits and in the leak testing of valve-cylinder assemblies.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-2A
Series 2
Capacity 30 gpm120 L/min.
Pilot Ratio 3:13:1
Maximum Recommended Load Pressure at Maximum Setting 3075 psi215 bar
Maximum Setting 4000 psi280 bar
Pilot Configuration StandardStandard
Factory Pressure Settings Established at 2 in³/min.30 cc/min.
Maximum Valve Leakage at Reseat 5 drops/min.0,3 cc/min.
Adjustment - Number of Counterclockwise Turns to Increase Setting 3.753.75
Operating Characteristic StandardStandard
Reseat >85% of setting>85% of setting
Valve Hex Size 1 1/8 in.28,6 mm
Valve Installation Torque 45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size 5/32 in.4 mm
Locknut Hex Size 9/16 in.15 mm
Locknut Torque 80 - 90 lbf in.9 - 10 Nm
Model Weight .60 lb0,30 kg
Seal kit - Cartridge Viton: 990-202-006

Show FAQ