You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
CBEWCDV


$124.60 USD
  • SUN HYDRAULICS
  • Material:CBEWCDV
  • Model:CBEW-CDV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CBEWCDV (CBEWCDV) is a sophisticated counterbalance valve with pilot assist designed to manage overrunning loads effectively. This product features a check valve that permits free flow from the directional valve port 2 to the load port 1, while a direct-acting, pilot-assisted relief valve controls the flow from port 1 to port 2. The pilot assist at port 3 reduces the effective setting of the relief valve based on the pilot ratio, enhancing operational flexibility and response under various load conditions. The CBEWCDV is engineered for precise control, with an adjustment feature that allows operators to set the pressure at least 1.3 times the maximum load-induced pressure to ensure stability and safety. It also includes two check valve cracking pressures to accommodate different application needs, making it versatile for use in various hydraulic systems. This model incorporates Sun's floating style construction which minimizes internal parts binding due to installation torque or machining variations in cavity-cartridge setups. It is designed for installation directly into machined cavities in actuator housings, which provides added protection and circuit stiffness. With a maximum flow capacity of 30 gpm (120 L/min) and a pilot ratio of 1:1, this valve supports a wide range of industrial applications requiring reliable load control. The factory-established settings ensure consistent performance across multiple units, making it suitable for complex hydraulic systems where precision and reliability are critical. Additionally, its design allows for easy maintenance and adjustment in field conditions, ensuring long-term operational efficiency and reduced downtime.

Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.

Other names for this valve include motion control valve and over center valve.

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Turn adjustment clockwise to decrease setting and release load.
  • Full clockwise setting is less than 200 psi (14 bar).
  • Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
  • This valve uses orifices to lower the pilot ratio and therefore will pass up to 40 in³/min./1000 psi (0,7 L/min./70 bar) between port 2 and port 3. This is a consideration in master-slave circuits and in the leak testing of valve-cylinder assemblies.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-2A
Series 2
Capacity 30 gpm120 L/min.
Pilot Ratio 1:11:1
Maximum Recommended Load Pressure at Maximum Setting 3075 psi215 bar
Maximum Setting 4000 psi280 bar
Factory Pressure Settings Established at 2 in³/min.30 cc/min.
Maximum Valve Leakage at Reseat 5 drops/min.0,3 cc/min.
Adjustment - Number of Counterclockwise Turns to Increase Setting 3.753.75
Operating Characteristic StandardStandard
Reseat >85% of setting>85% of setting
Valve Hex Size 1 1/8 in.28,6 mm
Valve Installation Torque 45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size 5/32 in.4 mm
Locknut Hex Size 9/16 in.15 mm
Locknut Torque 80 - 90 lbf in.9 - 10 Nm
Model Weight .60 lb0,30 kg
Seal kit - Cartridge Viton: 990-202-006

Show FAQ