SUN HYDRAULICS
CBGGLCV
$213.95 USD
- SUN HYDRAULICS
- Material:CBGGLCV
- Model:CBGG-LCV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CBGGLCV (CBGGLCV) is a meticulously engineered counterbalance valve designed to manage the control of overrunning loads in hydraulic systems. This valve features a check valve that permits free flow from the directional valve port 2 to load port 1, while a direct-acting, pilot-assisted relief valve regulates flow from port 1 to port 2. The pilot assist at port 3 effectively reduces the relief valve setting according to the pilot ratio, enhancing operational efficiency and safety. This model is optimized for settings at least 1.3 times the maximum load-induced pressure, with full clockwise settings being less than 200 psi (14 bar). It accommodates backpressure at port 2 by adding to the effective relief setting at a rate determined by one plus the pilot ratio times the backpressure. The CBGGLCV also boasts a reseat capability that exceeds 85% of set pressure under standard conditions. Designed for versatility in installation, Sun counterbalance cartridges can be directly installed into cavities machined in actuator housings, which improves protection and circuit stiffness. The valve ensures positive seals between all ports and offers two check valve cracking pressures to cater to different operational needs. Furthermore, it incorporates Sun’s floating style construction which minimizes internal parts binding due to excessive installation torque or cavity/cartridge machining variations. The CBGGLCV is suitable for use with phosphate ester fluids when configured with EPDM seals; however, exposure to petroleum-based fluids should be avoided as it can damage the seals. With a capacity of up to 60 gpm (240 L/min) and capable of handling maximum load pressures up to 3850 psi (270 bar), this model is an effective solution for sophisticated hydraulic applications requiring precise motion control and load handling capabilities.
The Sun Hydraulics CBGGLCV (CBGGLCV) is a meticulously engineered counterbalance valve designed to manage the control of overrunning loads in hydraulic systems. This valve features a check valve that permits free flow from the directional valve port 2 to load port 1, while a direct-acting, pilot-assisted relief valve regulates flow from port 1 to port 2. The pilot assist at port 3 effectively reduces the relief valve setting according to the pilot ratio, enhancing operational efficiency and safety. This model is optimized for settings at least 1.3 times the maximum load-induced pressure, with full clockwise settings being less than 200 psi (14 bar). It accommodates backpressure at port 2 by adding to the effective relief setting at a rate determined by one plus the pilot ratio times the backpressure. The CBGGLCV also boasts a reseat capability that exceeds 85% of set pressure under standard conditions. Designed for versatility in installation, Sun counterbalance cartridges can be directly installed into cavities machined in actuator housings, which improves protection and circuit stiffness. The valve ensures positive seals between all ports and offers two check valve cracking pressures to cater to different operational needs. Furthermore, it incorporates Sun’s floating style construction which minimizes internal parts binding due to excessive installation torque or cavity/cartridge machining variations. The CBGGLCV is suitable for use with phosphate ester fluids when configured with EPDM seals; however, exposure to petroleum-based fluids should be avoided as it can damage the seals. With a capacity of up to 60 gpm (240 L/min) and capable of handling maximum load pressures up to 3850 psi (270 bar), this model is an effective solution for sophisticated hydraulic applications requiring precise motion control and load handling capabilities.
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
- Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
- Turn adjustment clockwise to decrease setting and release load.
- Full clockwise setting is less than 200 psi (14 bar).
- Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
- Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
- Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
- This valve has positive seals between all ports.
- All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-17A |
| Series | 3 |
| Capacity | 60 gpm240 L/min. |
| Pilot Ratio | 4.5:14.5:1 |
| Maximum Recommended Load Pressure at Maximum Setting | 3850 psi270 bar |
| Maximum Setting | 5000 psi350 bar |
| Factory Pressure Settings Established at | 2 in³/min.30 cc/min. |
| Maximum Valve Leakage at Reseat | 5 drops/min.0,3 cc/min. |
| Adjustment - Number of Counterclockwise Turns to Increase Setting | 3.753.75 |
| Operating Characteristic | StandardStandard |
| Reseat | >85% of setting>85% of setting |
| Valve Hex Size | 1 1/4 in.31,8 mm |
| Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | 1.60 lb0,70 kg |
| Seal kit - Cartridge | Viton: 990-017-006 |
Show FAQ