SUN HYDRAULICS
CBGGLDV
$213.95 USD
- SUN HYDRAULICS
- Material:CBGGLDV
- Model:CBGG-LDV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CBGGLDV (CBGGLDV) is a sophisticated counterbalance valve designed to manage the control of overrunning loads in various hydraulic systems. This model is particularly effective due to its pilot-assisted relief valve capabilities, which facilitate controlled flow from port 1 to port 2, while its check valve allows free flow in the opposite direction. The pilot assist at port 3 significantly reduces the relief valve setting based on the pilot ratio, enhancing operational efficiency and safety. The CBGGLDV model supports a maximum flow capacity of 60 gpm (240 L/min) and can handle a maximum load pressure of up to 3850 psi (270 bar), with a maximum setting reaching up to 5000 psi (350 bar). It features a pilot ratio of 4.5:1, which ensures responsive and stable operation under varying load pressures. The design incorporates Sun’s floating style construction which minimizes potential internal binding caused by installation torque or cavity/cartridge machining discrepancies. This valve is highly adaptable with EPDM seals configured for systems using phosphate ester fluids, although it's important to avoid exposure to petroleum-based fluids which could damage the seals. It offers versatility in installation as it can be directly integrated into an actuator housing, boosting protection and circuit stiffness. The CBGGLDV also provides options for two check valve cracking pressures, enhancing its application suitability across different operational conditions. Designed for reliability, the CBGGLDV ensures minimal leakage at reseat—less than 5 drops/min at 0.3 cc/min—and boasts an adjustment mechanism that allows precise control over pressure settings. This counterbalance valve is an exemplary choice for systems requiring robust load control and enhanced stability in hydraulic operations.
The Sun Hydraulics CBGGLDV (CBGGLDV) is a sophisticated counterbalance valve designed to manage the control of overrunning loads in various hydraulic systems. This model is particularly effective due to its pilot-assisted relief valve capabilities, which facilitate controlled flow from port 1 to port 2, while its check valve allows free flow in the opposite direction. The pilot assist at port 3 significantly reduces the relief valve setting based on the pilot ratio, enhancing operational efficiency and safety. The CBGGLDV model supports a maximum flow capacity of 60 gpm (240 L/min) and can handle a maximum load pressure of up to 3850 psi (270 bar), with a maximum setting reaching up to 5000 psi (350 bar). It features a pilot ratio of 4.5:1, which ensures responsive and stable operation under varying load pressures. The design incorporates Sun’s floating style construction which minimizes potential internal binding caused by installation torque or cavity/cartridge machining discrepancies. This valve is highly adaptable with EPDM seals configured for systems using phosphate ester fluids, although it's important to avoid exposure to petroleum-based fluids which could damage the seals. It offers versatility in installation as it can be directly integrated into an actuator housing, boosting protection and circuit stiffness. The CBGGLDV also provides options for two check valve cracking pressures, enhancing its application suitability across different operational conditions. Designed for reliability, the CBGGLDV ensures minimal leakage at reseat—less than 5 drops/min at 0.3 cc/min—and boasts an adjustment mechanism that allows precise control over pressure settings. This counterbalance valve is an exemplary choice for systems requiring robust load control and enhanced stability in hydraulic operations.
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
- Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
- Turn adjustment clockwise to decrease setting and release load.
- Full clockwise setting is less than 200 psi (14 bar).
- Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
- Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
- Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
- This valve has positive seals between all ports.
- All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-17A |
| Series | 3 |
| Capacity | 60 gpm240 L/min. |
| Pilot Ratio | 4.5:14.5:1 |
| Maximum Recommended Load Pressure at Maximum Setting | 3850 psi270 bar |
| Maximum Setting | 5000 psi350 bar |
| Factory Pressure Settings Established at | 2 in³/min.30 cc/min. |
| Maximum Valve Leakage at Reseat | 5 drops/min.0,3 cc/min. |
| Adjustment - Number of Counterclockwise Turns to Increase Setting | 3.753.75 |
| Operating Characteristic | StandardStandard |
| Reseat | >85% of setting>85% of setting |
| Valve Hex Size | 1 1/4 in.31,8 mm |
| Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | 1.60 lb0,70 kg |
| Seal kit - Cartridge | Viton: 990-017-006 |
Show FAQ