SUN HYDRAULICS
CBHGLDV
$454.40 USD
- SUN HYDRAULICS
- Material:CBHGLDV
- Model:CBHG-LDV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CBHGLDV (CBHGLDV) is a counterbalance valve designed to manage the control of overrunning loads in hydraulic systems. It features a check valve that permits free flow from the directional valve port 2 to load port 1, while a direct-acting, pilot-assisted relief valve manages flow from port 1 to port 2. The addition of pilot assist at port 3 effectively reduces the setting of the relief valve according to a predetermined pilot ratio. This model is equipped with several key specifications that enhance its utility and performance in various applications. The CBHGLDV operates with a maximum setting of 5000 psi (350 bar) and a flow capacity up to 20 gpm (80 L/min). It also features an adjustable setting mechanism, which can be tuned by turning the adjustment screw clockwise to decrease pressure settings and release the load, with full clockwise adjustments lowering settings to less than 200 psi (14 bar). Additionally, backpressure at port 2 influences the effective relief setting at a rate determined by the pilot ratio times the backpressure plus one. The valve is designed for installation directly into machined cavities within actuator housings, which enhances protection and circuit stiffness. It offers two check valve cracking pressures, with a standard recommendation of 25 psi (1.7 bar) unless actuator cavitation is an issue. Furthermore, it incorporates Sun’s floating style construction which minimizes potential internal part binding due to excessive installation torque or variations in cavity/cartridge machining. For optimal performance and safety, settings should be established at least 1.3 times above maximum load-induced pressures, ensuring reliable operation under varying conditions. The design also allows for interchangeable use with all three-port counterbalance cartridges within the same frame size and flow path configuration.
The Sun Hydraulics CBHGLDV (CBHGLDV) is a counterbalance valve designed to manage the control of overrunning loads in hydraulic systems. It features a check valve that permits free flow from the directional valve port 2 to load port 1, while a direct-acting, pilot-assisted relief valve manages flow from port 1 to port 2. The addition of pilot assist at port 3 effectively reduces the setting of the relief valve according to a predetermined pilot ratio. This model is equipped with several key specifications that enhance its utility and performance in various applications. The CBHGLDV operates with a maximum setting of 5000 psi (350 bar) and a flow capacity up to 20 gpm (80 L/min). It also features an adjustable setting mechanism, which can be tuned by turning the adjustment screw clockwise to decrease pressure settings and release the load, with full clockwise adjustments lowering settings to less than 200 psi (14 bar). Additionally, backpressure at port 2 influences the effective relief setting at a rate determined by the pilot ratio times the backpressure plus one. The valve is designed for installation directly into machined cavities within actuator housings, which enhances protection and circuit stiffness. It offers two check valve cracking pressures, with a standard recommendation of 25 psi (1.7 bar) unless actuator cavitation is an issue. Furthermore, it incorporates Sun’s floating style construction which minimizes potential internal part binding due to excessive installation torque or variations in cavity/cartridge machining. For optimal performance and safety, settings should be established at least 1.3 times above maximum load-induced pressures, ensuring reliable operation under varying conditions. The design also allows for interchangeable use with all three-port counterbalance cartridges within the same frame size and flow path configuration.
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
- Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
- Restrictive valves have no relief capacity other than as a thermal relief.
- Turn adjustment clockwise to decrease setting and release load.
- Full clockwise setting is less than 200 psi (14 bar).
- Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
- Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
- Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
- Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
- This valve has positive seals between all ports.
- All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-19A |
| Series | 4 |
| Capacity | 20 gpm80 L/min. |
| Pilot Ratio | 4.5:14.5:1 |
| Maximum Recommended Load Pressure at Maximum Setting | 3850 psi270 bar |
| Maximum Setting | 5000 psi350 bar |
| Factory Pressure Settings Established at | 2 in³/min.30 cc/min. |
| Maximum Valve Leakage at Reseat | 5 drops/min.0,3 cc/min. |
| Adjustment - Number of Counterclockwise Turns to Increase Setting | 3.753.75 |
| Operating Characteristic | RestrictiveRestrictive |
| Reseat | >85% of setting>85% of setting |
| Valve Hex Size | 1 5/8 in.41,3 mm |
| Valve Installation Torque | 350 - 375 lbf ft474 - 508 Nm |
| Adjustment Screw Internal Hex Size | 7/32 in.5,5 mm |
| Locknut Hex Size | 3/4 in.19,1 mm |
| Locknut Torque | 25 - 30 lbf ft35 - 40 Nm |
| Model Weight | 3.00 lb1,35 kg |
| Seal kit - Cartridge | Viton: 990-019-006 |
Show FAQ