SUN HYDRAULICS
CCCACIN


$89.35 USD
  • SUN HYDRAULICS
  • Material:CCCACIN
  • Model:CCCA-CIN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CCCACIN (CCCACIN) is a meticulously engineered counterbalance valve designed for hydraulic systems requiring precise control over overrunning loads. This valve facilitates free flow from the directional valve port 2 to the load port 1, while a direct-acting relief valve manages flow from port 1 to port 2. Notably, this model does not include pilot assist, as the pilot assist area is internally nullified with no connection to port 3, establishing it as a zero pilot ratio unit which enhances machine stability at the cost of efficiency. The CCCACIN is set to handle maximum settings of up to 4000 psi (280 bar) and can operate under a maximum pressure of 5000 psi (350 bar). It features an adjustment mechanism where turning clockwise decreases the setting, allowing for controlled release of the load. The valve’s design incorporates a check valve that supports two cracking pressures, recommending a standard 25 psi unless actuator cavitation is a concern. For installation flexibility and enhanced performance, this counterbalance cartridge can be directly installed into cavities machined into an actuator housing. This integration not only protects the unit but also improves stiffness within the circuit. The construction of the CCCACIN uses Sun's floating style which minimizes internal parts binding—a common issue arising from excessive installation torque or cavity/cartridge machining variations. Additionally, its design allows for straightforward interchangeability with all 3-port counterbalance, load control, and pilot-to-open check cartridges within the same frame size and flow path. This model boasts robust corrosion resistance options suited for harsh environments; users can identify these by specific model code suffixes like AP for external stainless steel components or LH for external zinc-nickel plated components.

Counterbalance valves without pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting relief valve controls flow from port 1 to port 2.

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Turn adjustment clockwise to decrease setting and release load.
  • Full clockwise setting is less than 200 psi (14 bar).
  • These valves are modified versions of our pilot assisted counterbalance valves. The pilot assist area has been nullified internally. There is no connection to port 3.
  • Backpressure at port 2 is directly additive to the relief setting of the valve.
  • Lower pilot ratios (pilot gain) promote machine stability. This valve has a pilot ratio of zero. Stability is gained at the expense of efficiency.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-11A
Series 1
Capacity 15 gpm60 L/min.
Pilot Ratio ZeroZero
Maximum Recommended Load Pressure at Maximum Setting 3075 psi215 bar
Maximum Setting 4000 psi280 bar
Factory Pressure Settings Established at 2 in³/min.30 cc/min.
Maximum Operating Pressure 5000 psi350 bar
Maximum Valve Leakage at Reseat 5 drops/min.0,3 cc/min.
Adjustment - Number of Counterclockwise Turns to Increase Setting 3.753.75
Operating Characteristic StandardStandard
Reseat >85% of setting>85% of setting
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size 5/32 in.4 mm
Locknut Hex Size 9/16 in.15 mm
Locknut Torque 80 - 90 lbf in.9 - 10 Nm
Model Weight .40 lb0,20 kg
Seal kit - Cartridge Viton: 990-011-006