SUN HYDRAULICS
CCCAJIV
$93.32 USD
- SUN HYDRAULICS
- Material:CCCAJIV
- Model:CCCA-JIV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CCCAJIV (CCCAJIV) is a high-performance counterbalance valve designed for hydraulic systems requiring precise control of an overrunning load without pilot assist. This valve allows free flow from the directional valve port to the load port while controlling flow in the reverse direction through a direct-acting relief valve mechanism. It is engineered to handle a maximum setting of 4000 psi (280 bar) and can operate at a maximum pressure of 5000 psi (350 bar). The CCCAJIV features zero pilot ratio, enhancing machine stability by sacrificing some efficiency, which is critical in applications where control and prevention of load runaway are essential. This model also benefits from Sun Hydraulics' floating style construction, reducing the risk of internal parts binding due to installation issues or cavity-cartridge machining variations. The CCCAJIV has been designed to be installed directly into cavities machined into actuator housings, which provides added protection and improves circuit stiffness. With two available check valve cracking pressures, it offers flexibility in application based on specific system needs regarding actuator cavitation. Notably, the CCCAJIV does not use an external pilot line as the pilot assist area has been internally nullified. This design choice simplifies hydraulic circuits by eliminating connections to port 3 and enhances reliability by reducing potential leak points. Additionally, any backpressure at port 2 directly adds to the relief setting of the valve, making it crucial for users to consider system backpressure when setting up their valves. Overall, this model is ideal for heavy-duty applications where robustness and reliability are paramount in managing hydraulic loads effectively.
The Sun Hydraulics CCCAJIV (CCCAJIV) is a high-performance counterbalance valve designed for hydraulic systems requiring precise control of an overrunning load without pilot assist. This valve allows free flow from the directional valve port to the load port while controlling flow in the reverse direction through a direct-acting relief valve mechanism. It is engineered to handle a maximum setting of 4000 psi (280 bar) and can operate at a maximum pressure of 5000 psi (350 bar). The CCCAJIV features zero pilot ratio, enhancing machine stability by sacrificing some efficiency, which is critical in applications where control and prevention of load runaway are essential. This model also benefits from Sun Hydraulics' floating style construction, reducing the risk of internal parts binding due to installation issues or cavity-cartridge machining variations. The CCCAJIV has been designed to be installed directly into cavities machined into actuator housings, which provides added protection and improves circuit stiffness. With two available check valve cracking pressures, it offers flexibility in application based on specific system needs regarding actuator cavitation. Notably, the CCCAJIV does not use an external pilot line as the pilot assist area has been internally nullified. This design choice simplifies hydraulic circuits by eliminating connections to port 3 and enhances reliability by reducing potential leak points. Additionally, any backpressure at port 2 directly adds to the relief setting of the valve, making it crucial for users to consider system backpressure when setting up their valves. Overall, this model is ideal for heavy-duty applications where robustness and reliability are paramount in managing hydraulic loads effectively.
Counterbalance valves without pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting relief valve controls flow from port 1 to port 2.
- Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
- Turn adjustment clockwise to decrease setting and release load.
- Full clockwise setting is less than 200 psi (14 bar).
- These valves are modified versions of our pilot assisted counterbalance valves. The pilot assist area has been nullified internally. There is no connection to port 3.
- Backpressure at port 2 is directly additive to the relief setting of the valve.
- Lower pilot ratios (pilot gain) promote machine stability. This valve has a pilot ratio of zero. Stability is gained at the expense of efficiency.
- Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
- Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
- Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
- All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
- Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 15 gpm60 L/min. |
| Pilot Ratio | ZeroZero |
| Maximum Recommended Load Pressure at Maximum Setting | 3075 psi215 bar |
| Maximum Setting | 4000 psi280 bar |
| Factory Pressure Settings Established at | 2 in³/min.30 cc/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Valve Leakage at Reseat | 5 drops/min.0,3 cc/min. |
| Adjustment - Number of Counterclockwise Turns to Increase Setting | 3.753.75 |
| Operating Characteristic | StandardStandard |
| Reseat | >85% of setting>85% of setting |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .40 lb0,20 kg |
| Seal kit - Cartridge | Viton: 990-011-006 |
Show FAQ