You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
CCCARAV


$100.27 USD
  • SUN HYDRAULICS
  • Material:CCCARAV
  • Model:CCCA-RAV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CCCARAV (CCCARAV) is a counterbalance valve designed to manage the control of overrunning loads in hydraulic systems without the need for pilot assist. This valve features a check valve that permits free flow from the directional valve port 2 to the load port 1, while a direct-acting relief valve manages flow from port 1 to port 2. Engineered for settings to be at least 1.3 times the maximum load-induced pressure, this model allows adjustments by turning the adjustment screw clockwise to decrease settings and release load, with a full clockwise setting being less than 200 psi (14 bar). This model is a modified version of pilot-assisted counterbalance valves where the pilot assist area has been internally nullified, eliminating any connection to port 3. The backpressure at port 2 directly adds to the relief setting of the valve. Featuring a zero pilot ratio, this valve emphasizes stability over efficiency, which might affect performance in certain applications. The CCCARAV can handle a maximum operating pressure of 5000 psi (350 bar) and has a flow capacity of up to 15 gpm (60 L/min). It is designed for easy installation directly into actuator housings which enhances protection and circuit stiffness. Available in two check valve cracking pressures, it allows users to choose based on specific needs such as actuator cavitation concerns. Additionally, this model incorporates Sun’s floating style construction which minimizes potential internal parts binding caused by excessive installation torque or cavity/cartridge machining variations. This design feature helps ensure reliable operation and longevity of the valve in demanding applications.

Counterbalance valves without pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting relief valve controls flow from port 1 to port 2.

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Turn adjustment clockwise to decrease setting and release load.
  • Full clockwise setting is less than 200 psi (14 bar).
  • These valves are modified versions of our pilot assisted counterbalance valves. The pilot assist area has been nullified internally. There is no connection to port 3.
  • Backpressure at port 2 is directly additive to the relief setting of the valve.
  • Lower pilot ratios (pilot gain) promote machine stability. This valve has a pilot ratio of zero. Stability is gained at the expense of efficiency.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-11A
Series 1
Capacity 15 gpm60 L/min.
Pilot Ratio ZeroZero
Maximum Recommended Load Pressure at Maximum Setting 3075 psi215 bar
Maximum Setting 4000 psi280 bar
Factory Pressure Settings Established at 2 in³/min.30 cc/min.
Maximum Operating Pressure 5000 psi350 bar
Maximum Valve Leakage at Reseat 5 drops/min.0,3 cc/min.
Adjustment - Number of Counterclockwise Turns to Increase Setting 3.753.75
Operating Characteristic StandardStandard
Reseat >85% of setting>85% of setting
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size 5/32 in.4 mm
Locknut Hex Size 9/16 in.15 mm
Locknut Torque 80 - 90 lbf in.9 - 10 Nm
Model Weight .40 lb0,20 kg
Seal kit - Cartridge Viton: 990-011-006

Show FAQ