You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
CCEALHV


$119.24 USD
  • SUN HYDRAULICS
  • Material:CCEALHV
  • Model:CCEA-LHV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CCEALHV (CCEALHV) is a meticulously engineered counterbalance valve designed specifically for handling overrunning loads in hydraulic systems. This valve features a check valve that permits free flow from the directional valve port 2 to the load port 1, while a direct-acting relief valve manages flow from port 1 to port 2. The design of this model eliminates the pilot assist, having no connection to port 3 and achieving a pilot ratio of zero, which enhances machine stability albeit at some cost to efficiency. Constructed for robust performance, the CCEALHV can be directly installed into cavities machined into an actuator housing, which enhances protection and circuit stiffness. It supports up to 30 gpm (120 L/min) capacity and can withstand a maximum operating pressure of 5000 psi (350 bar). The valve is set to handle maximum load pressures up to 3075 psi (215 bar), with factory settings established at very precise flow rates. This model incorporates Sun’s floating style construction that minimizes potential binding of internal parts due to excessive installation torque or variations in cavity/cartridge machining. Its adjustment mechanism allows for precise control over the setting, with full clockwise adjustments reducing settings below 200 psi (14 bar). Additionally, two check valve cracking pressures are available for selection based on specific application needs. The CCEALHV is versatile in its interchangeability with all 3-port counterbalance, load control, and pilot-to-open check cartridges within the same frame size and cavity specifications. This feature simplifies replacements and upgrades within existing systems without necessitating major modifications. Furthermore, it is equipped with Viton seals for enhanced durability against fluid corrosiveness and temperature extremes.

Counterbalance valves without pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting relief valve controls flow from port 1 to port 2.

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Turn adjustment clockwise to decrease setting and release load.
  • Full clockwise setting is less than 200 psi (14 bar).
  • These valves are modified versions of our pilot assisted counterbalance valves. The pilot assist area has been nullified internally. There is no connection to port 3.
  • Backpressure at port 2 is directly additive to the relief setting of the valve.
  • Lower pilot ratios (pilot gain) promote machine stability. This valve has a pilot ratio of zero. Stability is gained at the expense of efficiency.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-2A
Series 2
Capacity 30 gpm120 L/min.
Pilot Ratio ZeroZero
Maximum Recommended Load Pressure at Maximum Setting 3075 psi215 bar
Maximum Setting 4000 psi280 bar
Factory Pressure Settings Established at 2 in³/min.30 cc/min.
Maximum Operating Pressure 5000 psi350 bar
Maximum Valve Leakage at Reseat 5 drops/min.0,3 cc/min.
Adjustment - Number of Counterclockwise Turns to Increase Setting 3.753.75
Operating Characteristic StandardStandard
Reseat >85% of setting>85% of setting
Valve Hex Size 1 1/8 in.28,6 mm
Valve Installation Torque 45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size 5/32 in.4 mm
Locknut Hex Size 9/16 in.15 mm
Locknut Torque 80 - 90 lbf in.9 - 10 Nm
Model Weight .60 lb0,30 kg
Seal kit - Cartridge Viton: 990-202-006

Show FAQ