You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
CCGARAV


$256.14 USD
  • SUN HYDRAULICS
  • Material:CCGARAV
  • Model:CCGA-RAV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CCGARAV (CCGARAV) is a meticulously engineered counterbalance valve designed for controlling overrunning loads without the need for pilot assistance. This valve features a check valve that permits free flow from the directional valve port 2 to the load port 1, while a direct-acting relief valve manages flow from port 1 to port 2. Uniquely modified from Sun Hydraulics' pilot-assisted counterbalance valves, the CCGARAV has an internally nullified pilot assist area and no connection to port 3, effectively making its pilot ratio zero. This design choice enhances machine stability at the cost of efficiency. The CCGARAV is set to handle maximum settings up to 4000 psi (280 bar), with factory pressure settings established at a flow rate of 2 in³/min (30 cc/min). It operates efficiently up to a maximum pressure of 5000 psi (350 bar). The valve's construction incorporates Sun's floating style, which minimizes internal parts binding — a common issue caused by excessive installation torque or variations in cavity/cartridge machining. For installation, this model can be directly integrated into cavities machined into actuator housings, enhancing protection and circuit stiffness. It offers two check valve cracking pressures, with a standard setting less than 200 psi (14 bar) when fully clockwise adjusted. The reseat capability exceeds 85% of set pressure under standard settings, ensuring reliable performance and reduced likelihood of drift in load control applications. This counterbalance valve is ideal for various hydraulic applications where stability is crucial and pilot assist is unnecessary or undesirable. Its robust design and precise manufacturing ensure long-term reliability and performance in demanding environments.

Counterbalance valves without pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting relief valve controls flow from port 1 to port 2.

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Turn adjustment clockwise to decrease setting and release load.
  • Full clockwise setting is less than 200 psi (14 bar).
  • These valves are modified versions of our pilot assisted counterbalance valves. The pilot assist area has been nullified internally. There is no connection to port 3.
  • Backpressure at port 2 is directly additive to the relief setting of the valve.
  • Lower pilot ratios (pilot gain) promote machine stability. This valve has a pilot ratio of zero. Stability is gained at the expense of efficiency.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-17A
Series 3
Capacity 60 gpm240 L/min.
Pilot Ratio ZeroZero
Maximum Recommended Load Pressure at Maximum Setting 3075 psi215 bar
Maximum Setting 4000 psi280 bar
Factory Pressure Settings Established at 2 in³/min.30 cc/min.
Maximum Operating Pressure 5000 psi350 bar
Maximum Valve Leakage at Reseat 5 drops/min.0,3 cc/min.
Adjustment - Number of Counterclockwise Turns to Increase Setting 3.753.75
Operating Characteristic StandardStandard
Reseat >85% of setting>85% of setting
Valve Hex Size 1 1/4 in.31,8 mm
Valve Installation Torque 150 - 160 lbf ft203 - 217 Nm
Adjustment Screw Internal Hex Size 5/32 in.4 mm
Locknut Hex Size 9/16 in.15 mm
Locknut Torque 80 - 90 lbf in.9 - 10 Nm
Model Weight 1.60 lb0,70 kg
Seal kit - Cartridge Viton: 990-017-006

Show FAQ