SUN HYDRAULICS
CCGARHV
$253.16 USD
- SUN HYDRAULICS
- Material:CCGARHV
- Model:CCGA-RHV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CCGARHV (CCGARHV) is a counterbalance valve designed without pilot assist, specifically engineered to manage overrunning loads effectively. This model features a check valve that permits free flow from the directional valve port 2 to load port 1, while a direct-acting relief valve regulates flow in the opposite direction, from port 1 to port 2. The absence of a pilot assist area, which has been internally nullified with no connection to port 3, marks a significant modification from Sun Hydraulics' pilot-assisted counterbalance valves. The CCGARHV is set to handle pressures at least 1.3 times the maximum load-induced pressure, with the ability for adjustment via clockwise turns to decrease settings and release load. The full clockwise setting falls below 200 psi (14 bar). It also features backpressure at port 2 that adds directly to the relief setting of the valve. The design incorporates a zero pilot ratio, which enhances machine stability but may reduce efficiency. This model boasts superior reseat capabilities, typically exceeding 85% of set pressure when standard set. Lower settings might result in decreased reseat percentages. All three-port counterbalance, load control, and pilot-to-open check cartridges by Sun are interchangeable within the same frame size and cavity (T17A Series 3), offering flexibility in application. The CCGARHV can handle up to 60 gpm (240 L/min) with a maximum operating pressure of 5000 psi (350 bar). It features an adjustment mechanism allowing up to 3.75 counterclockwise turns for setting increases and supports maximum recommended load pressures of up to 3075 psi (215 bar) when maximally set at 4000 psi (280 bar). Sun Hydraulics' floating style construction is utilized in this model to minimize potential internal parts binding due to excessive installation torque or variations in cavity/cartridge machining. This design choice aids in maintaining operational reliability and consistency across various hydraulic applications where precise control over heavy loads is critical.
The Sun Hydraulics CCGARHV (CCGARHV) is a counterbalance valve designed without pilot assist, specifically engineered to manage overrunning loads effectively. This model features a check valve that permits free flow from the directional valve port 2 to load port 1, while a direct-acting relief valve regulates flow in the opposite direction, from port 1 to port 2. The absence of a pilot assist area, which has been internally nullified with no connection to port 3, marks a significant modification from Sun Hydraulics' pilot-assisted counterbalance valves. The CCGARHV is set to handle pressures at least 1.3 times the maximum load-induced pressure, with the ability for adjustment via clockwise turns to decrease settings and release load. The full clockwise setting falls below 200 psi (14 bar). It also features backpressure at port 2 that adds directly to the relief setting of the valve. The design incorporates a zero pilot ratio, which enhances machine stability but may reduce efficiency. This model boasts superior reseat capabilities, typically exceeding 85% of set pressure when standard set. Lower settings might result in decreased reseat percentages. All three-port counterbalance, load control, and pilot-to-open check cartridges by Sun are interchangeable within the same frame size and cavity (T17A Series 3), offering flexibility in application. The CCGARHV can handle up to 60 gpm (240 L/min) with a maximum operating pressure of 5000 psi (350 bar). It features an adjustment mechanism allowing up to 3.75 counterclockwise turns for setting increases and supports maximum recommended load pressures of up to 3075 psi (215 bar) when maximally set at 4000 psi (280 bar). Sun Hydraulics' floating style construction is utilized in this model to minimize potential internal parts binding due to excessive installation torque or variations in cavity/cartridge machining. This design choice aids in maintaining operational reliability and consistency across various hydraulic applications where precise control over heavy loads is critical.
Counterbalance valves without pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting relief valve controls flow from port 1 to port 2.
- Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
- Turn adjustment clockwise to decrease setting and release load.
- Full clockwise setting is less than 200 psi (14 bar).
- These valves are modified versions of our pilot assisted counterbalance valves. The pilot assist area has been nullified internally. There is no connection to port 3.
- Backpressure at port 2 is directly additive to the relief setting of the valve.
- Lower pilot ratios (pilot gain) promote machine stability. This valve has a pilot ratio of zero. Stability is gained at the expense of efficiency.
- Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
- All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
- Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
- Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-17A |
| Series | 3 |
| Capacity | 60 gpm240 L/min. |
| Pilot Ratio | ZeroZero |
| Maximum Recommended Load Pressure at Maximum Setting | 3075 psi215 bar |
| Maximum Setting | 4000 psi280 bar |
| Factory Pressure Settings Established at | 2 in³/min.30 cc/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Valve Leakage at Reseat | 5 drops/min.0,3 cc/min. |
| Adjustment - Number of Counterclockwise Turns to Increase Setting | 3.753.75 |
| Operating Characteristic | StandardStandard |
| Reseat | >85% of setting>85% of setting |
| Valve Hex Size | 1 1/4 in.31,8 mm |
| Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | 1.60 lb0,70 kg |
| Seal kit - Cartridge | Viton: 990-017-006 |
Show FAQ