SUN HYDRAULICS
CCGARIN
$245.22 USD
- SUN HYDRAULICS
- Material:CCGARIN
- Model:CCGA-RIN
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CCGARIN (CCGARIN) is a robust counterbalance valve designed to manage overrunning loads effectively by controlling the flow between port 1 (load port) and port 2 (directional valve port). This model, which does not include pilot assist, utilizes a check valve to allow free flow from port 2 to port 1, while a direct-acting relief valve manages the flow from port 1 to port 2. The CCGARIN is engineered for stability over efficiency, as indicated by its zero pilot ratio, meaning the pilot assist area has been internally nullified with no connection to port 3. This valve is particularly suitable for applications where machine stability is critical. It should be set at least 1.3 times the maximum load-induced pressure, and the full clockwise setting reduces the pressure setting below 200 psi (14 bar). The counterbalance valves are designed with Sun's floating style construction that minimizes potential internal parts binding due to excessive installation torque or cavity/cartridge machining variations. The CCGARIN can handle a maximum flow of 60 gpm (240 L/min) and withstands a maximum operating pressure of 5000 psi (350 bar). Its factory settings are established at a flow rate of 2 in³/min (30 cc/min), ensuring precise operation out of the box. The adjustment mechanism allows for up to 3.75 turns counterclockwise to increase the setting, providing flexibility in application use. Additionally, it features a reseat capability that exceeds 85% of the set pressure under standard conditions. This model also offers versatility in installation as it can be directly mounted into an actuator housing cavity, enhancing protection and circuit stiffness. It supports two check valve cracking pressures but typically uses a 25 psi check unless actuator cavitation is an issue. The design ensures minimal leakage at reseat—less than five drops per minute—helping maintain system integrity and performance reliability in demanding environments.
The Sun Hydraulics CCGARIN (CCGARIN) is a robust counterbalance valve designed to manage overrunning loads effectively by controlling the flow between port 1 (load port) and port 2 (directional valve port). This model, which does not include pilot assist, utilizes a check valve to allow free flow from port 2 to port 1, while a direct-acting relief valve manages the flow from port 1 to port 2. The CCGARIN is engineered for stability over efficiency, as indicated by its zero pilot ratio, meaning the pilot assist area has been internally nullified with no connection to port 3. This valve is particularly suitable for applications where machine stability is critical. It should be set at least 1.3 times the maximum load-induced pressure, and the full clockwise setting reduces the pressure setting below 200 psi (14 bar). The counterbalance valves are designed with Sun's floating style construction that minimizes potential internal parts binding due to excessive installation torque or cavity/cartridge machining variations. The CCGARIN can handle a maximum flow of 60 gpm (240 L/min) and withstands a maximum operating pressure of 5000 psi (350 bar). Its factory settings are established at a flow rate of 2 in³/min (30 cc/min), ensuring precise operation out of the box. The adjustment mechanism allows for up to 3.75 turns counterclockwise to increase the setting, providing flexibility in application use. Additionally, it features a reseat capability that exceeds 85% of the set pressure under standard conditions. This model also offers versatility in installation as it can be directly mounted into an actuator housing cavity, enhancing protection and circuit stiffness. It supports two check valve cracking pressures but typically uses a 25 psi check unless actuator cavitation is an issue. The design ensures minimal leakage at reseat—less than five drops per minute—helping maintain system integrity and performance reliability in demanding environments.
Counterbalance valves without pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting relief valve controls flow from port 1 to port 2.
- Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
- Turn adjustment clockwise to decrease setting and release load.
- Full clockwise setting is less than 200 psi (14 bar).
- These valves are modified versions of our pilot assisted counterbalance valves. The pilot assist area has been nullified internally. There is no connection to port 3.
- Backpressure at port 2 is directly additive to the relief setting of the valve.
- Lower pilot ratios (pilot gain) promote machine stability. This valve has a pilot ratio of zero. Stability is gained at the expense of efficiency.
- Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
- All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
- Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
- Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-17A |
| Series | 3 |
| Capacity | 60 gpm240 L/min. |
| Pilot Ratio | ZeroZero |
| Maximum Recommended Load Pressure at Maximum Setting | 3075 psi215 bar |
| Maximum Setting | 4000 psi280 bar |
| Factory Pressure Settings Established at | 2 in³/min.30 cc/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Valve Leakage at Reseat | 5 drops/min.0,3 cc/min. |
| Adjustment - Number of Counterclockwise Turns to Increase Setting | 3.753.75 |
| Operating Characteristic | StandardStandard |
| Reseat | >85% of setting>85% of setting |
| Valve Hex Size | 1 1/4 in.31,8 mm |
| Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | 1.60 lb0,70 kg |
| Seal kit - Cartridge | Viton: 990-017-006 |