SUN HYDRAULICS
CCIACBV
$498.09 USD
- SUN HYDRAULICS
- Material:CCIACBV
- Model:CCIA-CBV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CCIACBV (CCIACBV) is a meticulously engineered counterbalance valve designed for controlling overrunning loads in hydraulic systems. This model operates without pilot assistance, featuring a zero pilot ratio which enhances machine stability albeit at the cost of efficiency. The valve allows free flow from port 2 to port 1 while a direct-acting relief valve manages flow from port 1 to port 2. Notably, the CCIACBV model has its pilot assist area internally nullified, eliminating any connection to port 3 and making backpressure at port 2 directly additive to the relief setting. This valve is set with a factory pressure setting established at a flow rate of 2 inches per minute (30 cc/min), and it should be adjusted to at least 1.3 times the maximum load-induced pressure for optimal performance. It features robust construction with Sun's floating style design that minimizes internal parts binding due to installation torque or cavity/cartridge machining variations. The maximum operating pressure stands at an impressive 5000 psi (350 bar), with a maximum flow capacity of 120 gpm (480 L/min). For installations requiring specific performance characteristics, two check valve cracking pressures are available; however, the standard 25 psi check is typically suitable unless actuator cavitation is a concern. The CCIACBV model also boasts compatibility with other three-port counterbalance, load control, and pilot-to-open check cartridges within the same frame size due to their interchangeable physical characteristics. This counterbalance valve is ideal for applications where stability is crucial and can be directly installed into an actuator housing for enhanced protection and stiffness in the circuit. Its design facilitates straightforward adjustments with clear guidelines on how to modify settings based on specific operational needs or conditions.
The Sun Hydraulics CCIACBV (CCIACBV) is a meticulously engineered counterbalance valve designed for controlling overrunning loads in hydraulic systems. This model operates without pilot assistance, featuring a zero pilot ratio which enhances machine stability albeit at the cost of efficiency. The valve allows free flow from port 2 to port 1 while a direct-acting relief valve manages flow from port 1 to port 2. Notably, the CCIACBV model has its pilot assist area internally nullified, eliminating any connection to port 3 and making backpressure at port 2 directly additive to the relief setting. This valve is set with a factory pressure setting established at a flow rate of 2 inches per minute (30 cc/min), and it should be adjusted to at least 1.3 times the maximum load-induced pressure for optimal performance. It features robust construction with Sun's floating style design that minimizes internal parts binding due to installation torque or cavity/cartridge machining variations. The maximum operating pressure stands at an impressive 5000 psi (350 bar), with a maximum flow capacity of 120 gpm (480 L/min). For installations requiring specific performance characteristics, two check valve cracking pressures are available; however, the standard 25 psi check is typically suitable unless actuator cavitation is a concern. The CCIACBV model also boasts compatibility with other three-port counterbalance, load control, and pilot-to-open check cartridges within the same frame size due to their interchangeable physical characteristics. This counterbalance valve is ideal for applications where stability is crucial and can be directly installed into an actuator housing for enhanced protection and stiffness in the circuit. Its design facilitates straightforward adjustments with clear guidelines on how to modify settings based on specific operational needs or conditions.
Counterbalance valves without pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting relief valve controls flow from port 1 to port 2.
- Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
- Turn adjustment clockwise to decrease setting and release load.
- Full clockwise setting is less than 200 psi (14 bar).
- These valves are modified versions of our pilot assisted counterbalance valves. The pilot assist area has been nullified internally. There is no connection to port 3.
- Backpressure at port 2 is directly additive to the relief setting of the valve.
- Lower pilot ratios (pilot gain) promote machine stability. This valve has a pilot ratio of zero. Stability is gained at the expense of efficiency.
- Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
- All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
- Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
- Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-19A |
| Series | 4 |
| Capacity | 120 gpm480 L/min. |
| Pilot Ratio | ZeroZero |
| Maximum Recommended Load Pressure at Maximum Setting | 3075 psi215 bar |
| Maximum Setting | 4000 psi280 bar |
| Factory Pressure Settings Established at | 2 in³/min.30 cc/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Valve Leakage at Reseat | 5 drops/min.0,3 cc/min. |
| Adjustment - Number of Counterclockwise Turns to Increase Setting | 3.753.75 |
| Operating Characteristic | StandardStandard |
| Reseat | >85% of setting>85% of setting |
| Valve Hex Size | 1 5/8 in.41,3 mm |
| Valve Installation Torque | 350 - 375 lbf ft474 - 508 Nm |
| Adjustment Screw Internal Hex Size | 7/32 in.5,5 mm |
| Locknut Hex Size | 3/4 in.19,1 mm |
| Locknut Torque | 25 - 30 lbf ft35 - 40 Nm |
| Model Weight | 3.00 lb1,35 kg |
| Seal kit - Cartridge | Viton: 990-019-006 |
Show FAQ